394 related articles for article (PubMed ID: 32972726)
21. Perioperative peri-implant fracture after osteosynthesis for geriatric femoral pertrochanteric fracture with the linear compression integrated screw intramedullary nail system (INTERTAN™): a retrospective study.
Lai CY; Liu CH; Lai PJ; Hsu YH; Chou YC; Yu YH
J Orthop Surg Res; 2023 Dec; 18(1):932. PubMed ID: 38057901
[TBL] [Abstract][Full Text] [Related]
22. Effect of fracture levels on the strength of bone-implant constructs in subtrochanteric fracture models fixed using short cephalomedullary nails: A finite element analysis.
Jang CY; Bang SH; Kim WH; Lee SJ; Lee HM; Kwak DK; Yoo JH
Injury; 2019 Nov; 50(11):1883-1888. PubMed ID: 31431331
[TBL] [Abstract][Full Text] [Related]
23. Biomechanical performance of short and long cephalomedullary nail constructs for stabilizing different levels of subtrochanteric fracture.
Chantarapanich N; Riansuwan K
Injury; 2022 Feb; 53(2):323-333. PubMed ID: 34969504
[TBL] [Abstract][Full Text] [Related]
24. [Off target of distal interlocking screw in short cephalomedullary nail fixation for intertrochanteric femur fractures].
Chang S; Du S; Hu S; Xiong W
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 Mar; 38(3):290-297. PubMed ID: 38500421
[TBL] [Abstract][Full Text] [Related]
25. Complications of short versus long cephalomedullary nail for intertrochanteric femur fractures, minimum 1 year follow-up.
Vaughn J; Cohen E; Vopat BG; Kane P; Abbood E; Born C
Eur J Orthop Surg Traumatol; 2015 May; 25(4):665-70. PubMed ID: 25337958
[TBL] [Abstract][Full Text] [Related]
26. [Research progress on distal interlocking screws of cephalomedullary nails in intertrochanteric fractures].
Qi Y; Wang X; Chang S
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 Mar; 38(3):356-362. PubMed ID: 38500431
[TBL] [Abstract][Full Text] [Related]
27. Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.
Lenz M; Acklin YP; Kasper LA; Mischler D; Varga P; Zderic I; Gehweiler D; Klos K; Gueorguiev B; Stoffel K
J Biomech; 2021 Jan; 115():110109. PubMed ID: 33257010
[TBL] [Abstract][Full Text] [Related]
28. Biomechanical analysis comparing titanium elastic nails with locked plating in two simulated pediatric femur fracture models.
Porter SE; Booker GR; Parsell DE; Weber MD; Russell GV; Woodall J; Wagner M; Neubauer T
J Pediatr Orthop; 2012 Sep; 32(6):587-93. PubMed ID: 22892620
[TBL] [Abstract][Full Text] [Related]
29. Biomechanical comparison of distal femoral fracture fixation: Polyaxial vs. uniaxial locking screws with different blocking screw configurations in retrograde femoral nailing.
Batar S; Söylemez MS; Bozdağ SE; Yaman E; Kemah B; Poyanlı OS
Orthop Traumatol Surg Res; 2024 Feb; 110(1):103695. PubMed ID: 37783426
[TBL] [Abstract][Full Text] [Related]
30. Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures: A cadaver-based laboratory investigation.
Pekmezci M; McDonald E; Buckley J; Kandemir U
Bone Joint J; 2014 Jan; 96-B(1):114-21. PubMed ID: 24395321
[TBL] [Abstract][Full Text] [Related]
31. Early complications associated with cephalomedullary nail for intertrochanteric hip fractures.
Erez O; Dougherty PJ
J Trauma Acute Care Surg; 2012 Feb; 72(2):E101-5. PubMed ID: 22439243
[TBL] [Abstract][Full Text] [Related]
32. The effect of different torque wrenches on rotational stiffness in compressive femoral nails: a biomechanical study.
Karaarslan AA; Acar N
Eur J Trauma Emerg Surg; 2018 Feb; 44(1):97-103. PubMed ID: 28752197
[TBL] [Abstract][Full Text] [Related]
33. Extra- vs. intramedullary treatment of pertrochanteric fractures: a biomechanical in vitro study comparing dynamic hip screw and intramedullary nail.
Weiser L; Ruppel AA; Nüchtern JV; Sellenschloh K; Zeichen J; Püschel K; Morlock MM; Lehmann W
Arch Orthop Trauma Surg; 2015 Aug; 135(8):1101-6. PubMed ID: 26054619
[TBL] [Abstract][Full Text] [Related]
34. A biomechanical comparison of the two- and four-hole side-plate dynamic hip screw in an osteoporotic composite femur model.
Rog D; Grigsby P; Hill Z; Pinette W; Inceoglu S; Zuckerman L
J Orthop Surg (Hong Kong); 2017; 25(2):2309499017717199. PubMed ID: 28664768
[TBL] [Abstract][Full Text] [Related]
35. Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the "Bell-Clapper Effect".
Auston D; Donohue D; Stoops K; Cox J; Diaz M; Santoni B; Mir H
J Orthop Trauma; 2018 Nov; 32(11):559-564. PubMed ID: 30086037
[TBL] [Abstract][Full Text] [Related]
36. Fixation of segmental subtrochanteric fractures. A biomechanical study.
Kraemer WJ; Hearn TC; Powell JN; Mahomed N
Clin Orthop Relat Res; 1996 Nov; (332):71-9. PubMed ID: 8913147
[TBL] [Abstract][Full Text] [Related]
37. Cortical encroachment after cephalomedullary nailing of the proximal femur: evaluation of a more anatomic radius of curvature.
Bazylewicz DB; Egol KA; Koval KJ
J Orthop Trauma; 2013 Jun; 27(6):303-7. PubMed ID: 23287752
[TBL] [Abstract][Full Text] [Related]
38. Short versus long cephalomedullary nails for the treatment of intertrochanteric hip fractures in patients older than 65 years.
Kleweno C; Morgan J; Redshaw J; Harris M; Rodriguez E; Zurakowski D; Vrahas M; Appleton P
J Orthop Trauma; 2014 Jul; 28(7):391-7. PubMed ID: 24231580
[TBL] [Abstract][Full Text] [Related]
39. Comparative biomechanical analysis of reconstruction and cephalomedullary nails in the treatment of osteoporotic subtrochanteric fractures.
Yoon YC; Kim JW; Kim TK; Oh CW; Park KH; Lee JH
Injury; 2024 Jun; 55(6):111512. PubMed ID: 38537396
[TBL] [Abstract][Full Text] [Related]
40. A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures.
Kuzyk PR; Shah S; Zdero R; Olsen M; Waddell JP; Schemitsch EH
J Trauma Acute Care Surg; 2012 Feb; 72(2):E65-70. PubMed ID: 22439235
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]