198 related articles for article (PubMed ID: 32976197)
1. Liver Stiffness Measured by Either Magnetic Resonance or Transient Elastography Is Associated With Liver Fibrosis and Is an Independent Predictor of Outcomes Among Patients With Primary Biliary Cholangitis.
Osman KT; Maselli DB; Idilman IS; Rowan DJ; Viehman JK; Harmsen WS; Harnois DM; Carey EJ; Gossard AA; LaRusso NF; Lindor KD; Venkatesh SK; Eaton JE
J Clin Gastroenterol; 2021 May-Jun 01; 55(5):449-457. PubMed ID: 32976197
[TBL] [Abstract][Full Text] [Related]
2. Performance of magnetic resonance elastography in primary sclerosing cholangitis.
Eaton JE; Dzyubak B; Venkatesh SK; Smyrk TC; Gores GJ; Ehman RL; LaRusso NF; Gossard AA; Lazaridis KN
J Gastroenterol Hepatol; 2016 Jun; 31(6):1184-90. PubMed ID: 26691631
[TBL] [Abstract][Full Text] [Related]
3. Changes in Liver Stiffness, Measured by Magnetic Resonance Elastography, Associated With Hepatic Decompensation in Patients With Primary Sclerosing Cholangitis.
Eaton JE; Sen A; Hoodeshenas S; Schleck CD; Harmsen WS; Gores GJ; LaRusso NF; Gossard AA; Lazaridis KN; Venkatesh SK
Clin Gastroenterol Hepatol; 2020 Jun; 18(7):1576-1583.e1. PubMed ID: 31683058
[TBL] [Abstract][Full Text] [Related]
4. Performance of transient elastography in assessing liver fibrosis in patients with autoimmune hepatitis-primary biliary cholangitis overlap syndrome.
Wu HM; Sheng L; Wang Q; Bao H; Miao Q; Xiao X; Guo CJ; Li H; Ma X; Qiu DK; Hua J
World J Gastroenterol; 2018 Feb; 24(6):737-743. PubMed ID: 29456412
[TBL] [Abstract][Full Text] [Related]
5. Non-invasive assessment of hepatic fibrosis: comparison of MR elastography to transient elastography and intravoxel incoherent motion diffusion-weighted MRI.
Fu F; Li X; Chen C; Bai Y; Liu Q; Shi D; Sang J; Wang K; Wang M
Abdom Radiol (NY); 2020 Jan; 45(1):73-82. PubMed ID: 31372777
[TBL] [Abstract][Full Text] [Related]
6. Magnetic resonance elastography in the assessment of hepatic fibrosis: a study comparing transient elastography and histological data in the same patients.
Toguchi M; Tsurusaki M; Yada N; Sofue K; Hyodo T; Onoda M; Numoto I; Matsuki M; Imaoka I; Kudo M; Murakami T
Abdom Radiol (NY); 2017 Jun; 42(6):1659-1666. PubMed ID: 28144720
[TBL] [Abstract][Full Text] [Related]
7. Two-dimensional Shear Wave Elastography with Propagation Maps for the Assessment of Liver Fibrosis and Clinically Significant Portal Hypertension in Patients with Chronic Liver Disease: A Prospective Study.
Jeon SK; Lee JM; Joo I; Yoon JH; Lee DH; Han JK
Acad Radiol; 2020 Jun; 27(6):798-806. PubMed ID: 31494001
[TBL] [Abstract][Full Text] [Related]
8. 2D shear wave elastography is better than transient elastography in predicting post-hepatectomy complication after resection.
Lee DH; Lee ES; Bae JS; Lee JY; Han JK; Yi NJ; Lee KW; Suh KS; Kim H; Lee KB; Choi BI
Eur Radiol; 2021 Aug; 31(8):5802-5811. PubMed ID: 33459859
[TBL] [Abstract][Full Text] [Related]
9. Comparison of the diagnostic accuracies of magnetic resonance elastography and transient elastography for hepatic fibrosis.
Ichikawa S; Motosugi U; Morisaka H; Sano K; Ichikawa T; Tatsumi A; Enomoto N; Matsuda M; Fujii H; Onishi H
Magn Reson Imaging; 2015 Jan; 33(1):26-30. PubMed ID: 25308096
[TBL] [Abstract][Full Text] [Related]
10. Noninvasive elastography-based assessment of liver fibrosis progression and prognosis in primary biliary cirrhosis.
Corpechot C; Carrat F; Poujol-Robert A; Gaouar F; Wendum D; Chazouillères O; Poupon R
Hepatology; 2012 Jul; 56(1):198-208. PubMed ID: 22271046
[TBL] [Abstract][Full Text] [Related]
11. An individual patient data meta-analysis to determine cut-offs for and confounders of NAFLD-fibrosis staging with magnetic resonance elastography.
Liang JX; Ampuero J; Niu H; Imajo K; Noureddin M; Behari J; Lee DH; Ehman RL; Rorsman F; Vessby J; Lacalle JR; Mózes FE; Pavlides M; Anstee QM; Harrison SA; Castell J; Loomba R; Romero-Gómez M;
J Hepatol; 2023 Sep; 79(3):592-604. PubMed ID: 37121437
[TBL] [Abstract][Full Text] [Related]
12. Systematic review and meta-analysis: Transient elastography compared to liver biopsy for staging of liver fibrosis in primary biliary cholangitis.
Manzo-Francisco LA; Aquino-Matus J; Vidaña-Pérez D; Uribe M; Chavez-Tapia N
Ann Hepatol; 2023; 28(4):101107. PubMed ID: 37088420
[TBL] [Abstract][Full Text] [Related]
13. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies.
Sporea I; Sirli RL; Deleanu A; Popescu A; Focsa M; Danila M; Tudora A
Ultraschall Med; 2011 Jan; 32 Suppl 1():S46-52. PubMed ID: 20603783
[TBL] [Abstract][Full Text] [Related]
14. Risk stratification in primary sclerosing cholangitis: comparison of biliary stricture severity on MRCP versus liver stiffness by MR elastography and vibration-controlled transient elastography.
Tafur M; Cheung A; Menezes RJ; Feld J; Janssen H; Hirschfield GM; Jhaveri KS
Eur Radiol; 2020 Jul; 30(7):3735-3747. PubMed ID: 32130494
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of Transient Elastography in Assessing Fibrosis at Diagnosis in Naïve Patients With Primary Biliary Cholangitis: A Dual Cut-Off Approach.
Cristoferi L; Calvaruso V; Overi D; Viganò M; Rigamonti C; Degasperi E; Cardinale V; Labanca S; Zucchini N; Fichera A; Di Marco V; Leutner M; Venere R; Picciotto A; Lucà M; Mulinacci G; Palermo A; Gerussi A; D'Amato D; Elisabeth O'Donnell S; Cerini F; De Benedittis C; Malinverno F; Ronca V; Mancuso C; Cazzagon N; Ciaccio A; Barisani D; Marzioni M; Floreani A; Alvaro D; Gaudio E; Invernizzi P; Carpino G; Nardi A; Carbone M;
Hepatology; 2021 Sep; 74(3):1496-1508. PubMed ID: 33724515
[TBL] [Abstract][Full Text] [Related]
16. Prospective comparison of transient, point shear wave, and magnetic resonance elastography for staging liver fibrosis.
Lefebvre T; Wartelle-Bladou C; Wong P; Sebastiani G; Giard JM; Castel H; Murphy-Lavallée J; Olivié D; Ilinca A; Sylvestre MP; Gilbert G; Gao ZH; Nguyen BN; Cloutier G; Tang A
Eur Radiol; 2019 Dec; 29(12):6477-6488. PubMed ID: 31278577
[TBL] [Abstract][Full Text] [Related]
17. Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis.
Kim SW; Lee JM; Park S; Joo I; Yoon JH; Chang W; Kim H
Korean J Radiol; 2022 Feb; 23(2):180-188. PubMed ID: 35029070
[TBL] [Abstract][Full Text] [Related]
18. Comparison of point shear wave elastography and transient elastography in the evaluation of patients with NAFLD.
Argalia G; Ventura C; Tosi N; Campioni D; Tagliati C; Tufillaro M; Cucco M; Svegliati Baroni G; Giovagnoni A
Radiol Med; 2022 May; 127(5):571-576. PubMed ID: 35290569
[TBL] [Abstract][Full Text] [Related]
19. Utility of magnetic resonance elastography for predicting ascites in patients with chronic liver disease.
Abe K; Takahashi A; Imaizumi H; Hayashi M; Okai K; Kanno Y; Sato N; Kenjo A; Marubashi S; Ohira H
J Gastroenterol Hepatol; 2018 Mar; 33(3):733-740. PubMed ID: 28834565
[TBL] [Abstract][Full Text] [Related]
20. Comparison of spin-echo echo-planar imaging magnetic resonance elastography with gradient-recalled echo magnetic resonance elastography and their correlation with transient elastography.
Yoon JW; Lee ES; Park HJ; Park SB; Cho YY; Kannengiesser S; Hur J
Diagn Interv Radiol; 2022 Jul; 28(4):294-300. PubMed ID: 35950274
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]