BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

329 related articles for article (PubMed ID: 32990514)

  • 1. Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels.
    Fletcher JG; Levin DL; Sykes AG; Lindell RM; White DB; Kuzo RS; Suresh V; Yu L; Leng S; Holmes DR; Inoue A; Johnson MP; Carter RE; McCollough CH
    Radiology; 2020 Dec; 297(3):699-707. PubMed ID: 32990514
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Observer Performance with Varying Radiation Dose and Reconstruction Methods for Detection of Hepatic Metastases.
    Fletcher JG; Fidler JL; Venkatesh SK; Hough DM; Takahashi N; Yu L; Johnson M; Leng S; Holmes DR; Carter R; McCollough CH
    Radiology; 2018 Nov; 289(2):455-464. PubMed ID: 30204077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Estimation of Observer Performance for Reduced Radiation Dose Levels in CT: Eliminating Reduced Dose Levels That Are Too Low Is the First Step.
    Fletcher JG; Yu L; Fidler JL; Levin DL; DeLone DR; Hough DM; Takahashi N; Venkatesh SK; Sykes AG; White D; Lindell RM; Kotsenas AL; Campeau NG; Lehman VT; Bartley AC; Leng S; Holmes DR; Toledano AY; Carter RE; McCollough CH
    Acad Radiol; 2017 Jul; 24(7):876-890. PubMed ID: 28262519
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
    Gordic S; Morsbach F; Schmidt B; Allmendinger T; Flohr T; Husarik D; Baumueller S; Raupach R; Stolzmann P; Leschka S; Frauenfelder T; Alkadhi H
    Invest Radiol; 2014 Jul; 49(7):465-73. PubMed ID: 24598443
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sub-solid Nodule Detection Performance on Reduced-dose Computed Tomography with Iterative Reduction: Comparison Between 20 mA (7 mAs) and 120 mA (42 mAs) Regarding Nodular Size and Characteristics and Association with Size-specific Dose Estimate.
    Nagatani Y; Takahashi M; Ikeda M; Yamashiro T; Koyama H; Koyama M; Moriya H; Noma S; Tomiyama N; Ohno Y; Murata K; Murayama S;
    Acad Radiol; 2017 Aug; 24(8):995-1007. PubMed ID: 28606593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Observer Performance in the Detection and Classification of Malignant Hepatic Nodules and Masses with CT Image-Space Denoising and Iterative Reconstruction.
    Fletcher JG; Yu L; Li Z; Manduca A; Blezek DJ; Hough DM; Venkatesh SK; Brickner GC; Cernigliaro JC; Hara AK; Fidler JL; Lake DS; Shiung M; Lewis D; Leng S; Augustine KE; Carter RE; Holmes DR; McCollough CH
    Radiology; 2015 Aug; 276(2):465-78. PubMed ID: 26020436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT.
    Sui X; Meinel FG; Song W; Xu X; Wang Z; Wang Y; Jin Z; Chen J; Vliegenthart R; Schoepf UJ
    Eur J Radiol; 2016 Mar; 85(3):564-70. PubMed ID: 26860668
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Systematic error in lung nodule volumetry: effect of iterative reconstruction versus filtered back projection at different CT parameters.
    Willemink MJ; Leiner T; Budde RP; de Kort FP; Vliegenthart R; van Ooijen PM; Oudkerk M; de Jong PA
    AJR Am J Roentgenol; 2012 Dec; 199(6):1241-6. PubMed ID: 23169714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules: Intra-individual comparison.
    Den Harder AM; Willemink MJ; van Hamersvelt RW; Vonken EJ; Milles J; Schilham AM; Lammers JW; de Jong PA; Leiner T; Budde RP
    Eur J Radiol; 2016 Feb; 85(2):346-51. PubMed ID: 26781139
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT.
    Jiang B; Li N; Shi X; Zhang S; Li J; de Bock GH; Vliegenthart R; Xie X
    Radiology; 2022 Apr; 303(1):202-212. PubMed ID: 35040674
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT.
    Tang H; Liu Z; Hu Z; He T; Li D; Yu N; Jia Y; Shi H
    Br J Radiol; 2019 Nov; 92(1103):20180909. PubMed ID: 31469289
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13mSv.
    Messerli M; Kluckert T; Knitel M; Rengier F; Warschkow R; Alkadhi H; Leschka S; Wildermuth S; Bauer RW
    Eur J Radiol; 2016 Dec; 85(12):2217-2224. PubMed ID: 27842670
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study.
    Martini K; Higashigaito K; Barth BK; Baumueller S; Alkadhi H; Frauenfelder T
    Br J Radiol; 2015; 88(1056):20150389. PubMed ID: 26492317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of deep learning image reconstruction on volumetric accuracy and image quality of pulmonary nodules with different morphologies in low-dose CT.
    D'hondt L; Franck C; Kellens PJ; Zanca F; Buytaert D; Van Hoyweghen A; Addouli HE; Carpentier K; Niekel M; Spinhoven M; Bacher K; Snoeckx A
    Cancer Imaging; 2024 May; 24(1):60. PubMed ID: 38720391
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development and Validation of Deep Learning-based Automatic Detection Algorithm for Malignant Pulmonary Nodules on Chest Radiographs.
    Nam JG; Park S; Hwang EJ; Lee JH; Jin KN; Lim KY; Vu TH; Sohn JH; Hwang S; Goo JM; Park CM
    Radiology; 2019 Jan; 290(1):218-228. PubMed ID: 30251934
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Standard-, Reduced-, and No-Dose Thin-Section Radiologic Examinations: Comparison of Capability for Nodule Detection and Nodule Type Assessment in Patients Suspected of Having Pulmonary Nodules.
    Ohno Y; Koyama H; Yoshikawa T; Kishida Y; Seki S; Takenaka D; Yui M; Miyazaki M; Sugimura K
    Radiology; 2017 Aug; 284(2):562-573. PubMed ID: 28263700
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (<4 mm) renal stones.
    Wells ML; Froemming AT; Kawashima A; Vrtiska TJ; Kim B; Hartman RP; Holmes DR; Carter RE; Bartley AC; Leng S; McCollough CH; Fletcher JG
    Acta Radiol; 2017 Aug; 58(8):1012-1019. PubMed ID: 28273736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique.
    Katsura M; Matsuda I; Akahane M; Yasaka K; Hanaoka S; Akai H; Sato J; Kunimatsu A; Ohtomo K
    Invest Radiol; 2013 Apr; 48(4):206-12. PubMed ID: 23344517
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations.
    Neroladaki A; Botsikas D; Boudabbous S; Becker CD; Montet X
    Eur Radiol; 2013 Feb; 23(2):360-6. PubMed ID: 22892722
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Observer performance for adaptive, image-based denoising and filtered back projection compared to scanner-based iterative reconstruction for lower dose CT enterography.
    Fletcher JG; Hara AK; Fidler JL; Silva AC; Barlow JM; Carter RE; Bartley A; Shiung M; Holmes DR; Weber NK; Bruining DH; Yu L; McCollough CH
    Abdom Imaging; 2015 Jun; 40(5):1050-9. PubMed ID: 25725794
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.