These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 32992404)

  • 1. [Comparison of the Accuracy of the Measurement of Fetal Hemoglobin by Blood Gas Analysis and by Laboratory Gold Standard: a Prospective Diagnostic Study].
    Wittenmeier E; Lesmeister L; Schmidtmann I; Lotz J; Dette F; Mildenberger E
    Z Geburtshilfe Neonatol; 2021 Jun; 225(3):257-261. PubMed ID: 32992404
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study.
    Wittenmeier E; Bellosevich S; Mauff S; Schmidtmann I; Eli M; Pestel G; Noppens RR
    Paediatr Anaesth; 2015 Oct; 25(10):1046-53. PubMed ID: 26179143
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the blood analyzer ABL 735 radiometer for determination of the percentage of fetal hemoglobin in fetal and neonatal blood.
    Egberts J; Van Pelt J
    Scand J Clin Lab Invest; 2004 Apr; 64(2):128-31. PubMed ID: 15115250
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of measurements of HbF with OSM3 in neonates and infants.
    Denjean A; Bridey F; Praud JP; Magny JF; Dehan M; Gaultier C
    Eur Respir J; 1992 Jan; 5(1):105-7. PubMed ID: 1374349
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of haemoglobin measurement by several methods - blood gas analyser, capillary and venous HemoCue
    Wittenmeier E; Lesmeister L; Pirlich N; Dette F; Schmidtmann I; Mildenberger E
    Anaesthesia; 2019 Feb; 74(2):197-202. PubMed ID: 30427065
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of bias in measurements of potassium, sodium and hemoglobin by an emergency department-based blood gas analyzer relative to hospital laboratory autoanalyzer results.
    Zhang JB; Lin J; Zhao XD
    PLoS One; 2015; 10(4):e0122383. PubMed ID: 25849375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Blood volume assessment with hemoglobin subtype analysis in preterm infants.
    Leipälä JA; Talme M; Viitala J; Turpeinen U; Fellman V
    Biol Neonate; 2003; 84(1):41-4. PubMed ID: 12890935
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Masimo Total Hemoglobin SpHb® continuous non-invasive hemoglobin monitoring device with laboratory complete blood count measurement using venous sample: Protocol for an observational substudy of the Pregnancy Risk and Infant Surveillance and Measurement Alliance Maternal and Newborn Health (PRISMA MNH) study.
    Farooq F; Smith ER; Pan Q; Glass Baumann S; Akelo V; Jehan F; Kasaro M; Nisar I; Ouma G; Vwalika B; Spelke MB; Price JT; Hoodbhoy Z
    Gates Open Res; 2023; 7():50. PubMed ID: 37868333
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors influencing the bias between blood gas analysis versus central laboratory hemoglobin testing. A secondary analysis of a randomized controlled trial.
    Tanner L; Lindau S; Velten M; Schlesinger T; Wittmann M; Kranke P; Berg K; Piekarski F; Füllenbach C; Choorapoikayil S; Hasenclever D; Zacharowski K; Meybohm P
    PLoS One; 2020; 15(10):e0240721. PubMed ID: 33125405
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of point-of-care-testing (POCT) for determining hemoglobin concentrations.
    Gehring H; Hornberger C; Dibbelt L; Rothsigkeit A; Gerlach K; Schumacher J; Schmucker P
    Acta Anaesthesiol Scand; 2002 Sep; 46(8):980-6. PubMed ID: 12190799
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Do Lower Levels of Fetal Hemoglobin in Preterm Infants Relate to Oxidative Stress?
    Torrejón-Rodríguez L; Parra-Llorca A; Pinilla-González A; Lara-Cantón I; Albiach-Delgado A; Cernada M; Escrig R; Kuligowski J; Aguar Carrascosa M; Vento Torres M
    Antioxid Redox Signal; 2024 Mar; 40(7-9):453-459. PubMed ID: 37603496
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fetal haemoglobin and bronchopulmonary dysplasia in neonates: an observational study.
    Hellström W; Martinsson T; Hellstrom A; Morsing E; Ley D
    Arch Dis Child Fetal Neonatal Ed; 2021 Jan; 106(1):88-92. PubMed ID: 32847833
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter.
    Shiao SY; Ou CN; Pierantoni H
    Clin Chim Acta; 2006 Dec; 374(1-2):75-80. PubMed ID: 16844104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Invasive Arterial Blood Pressure Monitoring vs. Non-Invasive Blood Pressure Monitoring in Preterm Infants < 37 Weeks in the Neonatal Intensive Care Unit- A Prospective Observational Study.
    Shah S; Kaul A; Khandare J; Dhalait S
    J Trop Pediatr; 2021 Dec; 67(6):. PubMed ID: 34966946
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Clinical Utility of Noninvasive Pulse Co-oximetry Hemoglobin Measurements in Dark-Skinned Critically Ill Patients.
    Murphy SM; Omar S
    Anesth Analg; 2018 May; 126(5):1519-1526. PubMed ID: 29239951
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Clinical study of neonatal cardiac output measurement methods].
    Zheng ML; Sun X; Zhong J; He SR; Pan W; Pang CC; Sun YX; Liu YM
    Zhonghua Er Ke Za Zhi; 2013 Jan; 51(1):58-63. PubMed ID: 23527933
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemoglobin oxygen dissociation (P50) in bronchopulmonary dysplasia.
    Furfaro S; Prosmanne J; Bard H
    Biol Neonate; 1990; 57(2):72-6. PubMed ID: 1690029
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the Element point-of-care blood gas analyzer for use in horses.
    Krueger CR; Hackett ES; Hess AM; Mama KR
    J Vet Emerg Crit Care (San Antonio); 2020 May; 30(3):279-285. PubMed ID: 32187439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measured quantities in perinatal medicine--the base excess].
    Roemer VM
    Z Geburtshilfe Neonatol; 2005 Jun; 209(3):81-9. PubMed ID: 15995940
    [TBL] [Abstract][Full Text] [Related]  

  • 20. From oxygen content to pulse oximetry: completing the picture in the newborn.
    Whyte RK; Jangaard KA; Dooley KC
    Acta Anaesthesiol Scand Suppl; 1995; 107():95-100. PubMed ID: 8599308
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.