These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 32992404)
21. [Evaluation of the measurement of hemoglobin by the Hemocue System® in the preterm neonate less than 28 days old]. Barcat L; Dekens C; Caron-Lesenechal E; Degorre C; Cauliez A; Riou B; Vasseur A; Gromada V; Leke A; Bach V; Tourneux P Arch Pediatr; 2016 Mar; 23(3):255-60. PubMed ID: 26795359 [TBL] [Abstract][Full Text] [Related]
22. Near-patient measurements of methemoglobin, oxygen saturation, and total hemoglobin: evaluation of a new instrument for adult and neonatal intensive care. Gong AK Crit Care Med; 1995 Jan; 23(1):193-201. PubMed ID: 7528117 [TBL] [Abstract][Full Text] [Related]
23. Lower foetal haemoglobin levels at 31- and 34-weeks post menstrual age is associated with the development of retinopathy of prematurity : PacIFiHER Report No. 1 PacIFiHER Study Group (Preterm Infants and Fetal Haemoglobin in ROP). Jiramongkolchai K; Repka MX; Tian J; Aucott SW; Shepard J; Collins M; Kraus C; Clemens J; Feller M; Burd I; Roizenblatt M; Goldberg MF; Arevalo JF; Gehlbach P; Handa JT Eye (Lond); 2021 Feb; 35(2):659-664. PubMed ID: 32409707 [TBL] [Abstract][Full Text] [Related]
25. Comparison of Hemoglobin Measurements by 3 Point-of-Care Devices With Standard Laboratory Values and Reliability Regarding Decisions for Blood Transfusion. Johnson M; Marwick PC; Coetzee JF Anesth Analg; 2020 Aug; 131(2):640-649. PubMed ID: 31764158 [TBL] [Abstract][Full Text] [Related]
26. Compatibility levels between blood gas analysis and central laboratory hemoglobin and electrolyte tests in pediatric patients: A single-center experience. Konuksever D; Yucel SP; Bölük O; Kılıç BO; Taşar MA Paediatr Anaesth; 2023 Feb; 33(2):107-113. PubMed ID: 36178754 [TBL] [Abstract][Full Text] [Related]
27. Hemoglobin switch in the newborn: a flow cytometry analysis. Amoyal I; Fibach E Neonatology; 2007; 91(1):61-8. PubMed ID: 17344654 [TBL] [Abstract][Full Text] [Related]
28. Accuracy of noninvasive and invasive point-of-care total blood hemoglobin measurement in an outpatient setting. Raikhel M Postgrad Med; 2012 Jul; 124(4):250-5. PubMed ID: 22913913 [TBL] [Abstract][Full Text] [Related]
29. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery. Chang AC; Kulik TJ; Hickey PR; Wessel DL Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302 [TBL] [Abstract][Full Text] [Related]
30. Systematic comparison of four point-of-care methods versus the reference laboratory measurement of hemoglobin in the surgical ICU setting: a cross-sectional method comparison study. Chutipongtanate A; Yasaeng C; Virankabutra T; Chutipongtanate S BMC Anesthesiol; 2020 Apr; 20(1):92. PubMed ID: 32321425 [TBL] [Abstract][Full Text] [Related]
31. Elevated levels of fetal hemoglobin synthesis in infants with bronchopulmonary dysplasia. Bard H; Prosmanne J Pediatrics; 1990 Aug; 86(2):193-6. PubMed ID: 1695343 [TBL] [Abstract][Full Text] [Related]
32. The relation between newborn hemoglobin F fractions and risk factors for sudden infant death syndrome. Cochran-Black DL; Cowan LD; Neas BR Arch Pathol Lab Med; 2001 Feb; 125(2):211-7. PubMed ID: 11175637 [TBL] [Abstract][Full Text] [Related]
33. Identification and quantification of hemoglobins in whole blood: the analytical and organizational aspects of Capillarys 2 Flex Piercing compared with agarose electrophoresis and HPLC methods. Altinier S; Varagnolo M; Zaninotto M; Plebani M Clin Chem Lab Med; 2013 Apr; 51(4):791-7. PubMed ID: 23072852 [TBL] [Abstract][Full Text] [Related]
34. Accuracy of two wavelength pulse oximetry in neonates and infants. Praud JP; Carofilis A; Bridey F; Lacaille F; Dehan M; Gaultier CL Pediatr Pulmonol; 1989; 6(3):180-2. PubMed ID: 2470014 [TBL] [Abstract][Full Text] [Related]
35. Oxygen affinity of haemoglobin modulates cerebral blood flow in premature infants. A study with the non-invasive xenon-133 method. Lipp-Zwahlen AE; Müller A; Tuchschmid P; Duc G Acta Paediatr Scand Suppl; 1989; 360():26-32. PubMed ID: 2484461 [TBL] [Abstract][Full Text] [Related]
36. Evaluation of noninvasive hemoglobin monitoring in children with congenital heart diseases. Kamel MM; Hasanin A; Nawar B; Mostafa M; Jacob VF; Elhadi H; Alsadek W; Elmetwally SA Paediatr Anaesth; 2020 May; 30(5):571-576. PubMed ID: 32160358 [TBL] [Abstract][Full Text] [Related]
37. The reactivation of fetal hemoglobin synthesis during anemia of prematurity. Bard H; Lachance C; Widness JA; Gagnon C Pediatr Res; 1994 Aug; 36(2):253-6. PubMed ID: 7526326 [TBL] [Abstract][Full Text] [Related]
38. Interchangeability of blood gas, electrolyte and metabolite results measured with point-of-care, blood gas and core laboratory analyzers. Leino A; Kurvinen K Clin Chem Lab Med; 2011 Jul; 49(7):1187-91. PubMed ID: 21504373 [TBL] [Abstract][Full Text] [Related]
39. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Frasca D; Dahyot-Fizelier C; Catherine K; Levrat Q; Debaene B; Mimoz O Crit Care Med; 2011 Oct; 39(10):2277-82. PubMed ID: 21666449 [TBL] [Abstract][Full Text] [Related]
40. The effect of blood transfusion on the hemoglobin oxygen dissociation curve of very early preterm infants during the first week of life. De Halleux V; Truttmann A; Gagnon C; Bard H Semin Perinatol; 2002 Dec; 26(6):411-5. PubMed ID: 12537312 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]