These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
173 related articles for article (PubMed ID: 32998134)
1. Validation of a New Transcutaneous tcPO2/tcPCO2 Sensor with an Optical Oxygen Measurement in Preterm Neonates. van Weteringen W; van Essen T; Gangaram-Panday NH; Goos TG; de Jonge RCJ; Reiss IKM Neonatology; 2020; 117(5):628-636. PubMed ID: 32998134 [TBL] [Abstract][Full Text] [Related]
2. Novel transcutaneous sensor combining optical tcPO van Weteringen W; Goos TG; van Essen T; Ellenberger C; Hayoz J; de Jonge RCJ; Reiss IKM; Schumacher PM Med Biol Eng Comput; 2020 Feb; 58(2):239-247. PubMed ID: 31741291 [TBL] [Abstract][Full Text] [Related]
3. Validation of a new combined transcutaneous tcPCO van Wijk JJ; van Weteringen W; Hoeks SE; Staals LM Paediatr Anaesth; 2022 Mar; 32(3):429-435. PubMed ID: 34882905 [TBL] [Abstract][Full Text] [Related]
4. Transcutaneous blood gas monitoring among neonatal intensive care units in Japan. Ochiai M; Kurata H; Inoue H; Ichiyama M; Fujiyoshi J; Watabe S; Hiroma T; Nakamura T; Ohga S Pediatr Int; 2020 Feb; 62(2):169-174. PubMed ID: 31845473 [TBL] [Abstract][Full Text] [Related]
5. Long-term transcutaneous monitoring of oxygen tension and carbon dioxide at 42 degrees C in critically ill neonates: improved performance of the tcpo2 monitor with topical metabolic inhibition. Fanconi S; Tschupp A; Molinari L Eur J Pediatr; 1996 Dec; 155(12):1043-6. PubMed ID: 8956942 [TBL] [Abstract][Full Text] [Related]
6. Effect of electrode temperature on measurements of transcutaneous carbon dioxide partial pressure and oxygen partial pressure in very low birth weight infants. Li BH; Zhao CL; Cao SL; Geng HL; Li JJ; Zhu M; Niu SP Zhongguo Dang Dai Er Ke Za Zhi; 2021 Aug; 23(8):809-813. PubMed ID: 34511170 [TBL] [Abstract][Full Text] [Related]
7. Transcutaneous carbon dioxide monitoring during therapeutic hypothermia for neonatal encephalopathy. Gangaram-Panday NH; van Essen T; van Weteringen W; Dremmen MHG; Goos TG; de Jonge RCJ; Reiss IKM Pediatr Res; 2022 Dec; 92(6):1724-1730. PubMed ID: 35352004 [TBL] [Abstract][Full Text] [Related]
8. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia. Nishiyama T; Nakamura S; Yamashita K Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244 [TBL] [Abstract][Full Text] [Related]
9. Transcutaneous measurement of carbon dioxide tension: effect of sleep state in term infants. Martin RJ; Herrell N; Pultusker M Pediatrics; 1981 May; 67(5):622-5. PubMed ID: 6789297 [TBL] [Abstract][Full Text] [Related]
10. Transcutaneous PCO2 Measurement at Low Temperature for Reliable and Continuous Free Flap Monitoring: Experimental and Clinical Study. Abe Y; Hashimoto I; Goishi K; Kashiwagi K; Yamano M; Nakanishi H Plast Reconstr Surg Glob Open; 2013 May; 1(2):1-8. PubMed ID: 25289213 [TBL] [Abstract][Full Text] [Related]
11. Transcutaneous oxygen and carbon dioxide levels with iloprost administration in diabetic critical limb ischemia. Melillo E; Ferrari M; Balbarini A; Pedrinelli R Vasc Endovascular Surg; 2006; 40(4):303-11. PubMed ID: 16959724 [TBL] [Abstract][Full Text] [Related]
12. Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device. Janssens JP; Howarth-Frey C; Chevrolet JC; Abajo B; Rochat T Chest; 1998 Mar; 113(3):768-73. PubMed ID: 9515855 [TBL] [Abstract][Full Text] [Related]
13. Feasibilty of Transcutaneous pCO Bresesti I; Bruckner M; Mattersberger C; Baik-Schneditz N; Schwaberger B; Mileder L; Avian A; Urlesberger B; Pichler G Front Pediatr; 2020; 8():11. PubMed ID: 32064242 [No Abstract] [Full Text] [Related]
14. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor. Bendjelid K; Schütz N; Stotz M; Gerard I; Suter PM; Romand JA Crit Care Med; 2005 Oct; 33(10):2203-6. PubMed ID: 16215371 [TBL] [Abstract][Full Text] [Related]
15. Improved oxygenation with prone positioning in neonates: stability of increased transcutaneous PO2. Baird TM; Paton JB; Fisher DE J Perinatol; 1991 Dec; 11(4):315-8. PubMed ID: 1770386 [TBL] [Abstract][Full Text] [Related]
16. Comparison of transcutaneous oxygen and carbon dioxide monitors in normal adults and critically ill patients. Rithalia SV; Farrow P; Doran BR Intensive Crit Care Nurs; 1992 Mar; 8(1):40-6. PubMed ID: 1559023 [TBL] [Abstract][Full Text] [Related]
17. Transcutaneous oxygen and carbon dioxide pressure monitoring to determine severity of limb ischemia and to predict surgical outcome. Lalka SG; Malone JM; Anderson GG; Hagaman RM; McIntyre KE; Bernhard VM J Vasc Surg; 1988 Apr; 7(4):507-14. PubMed ID: 3352067 [TBL] [Abstract][Full Text] [Related]
19. Transcutaneous blood gas monitoring and tissue perfusion during common femoral thromboendarterectomy. Sigvardt E; Rasmussen SM; Eiberg JP; Sørensen HBD; Meyhoff CS; Aasvang EK Scand J Clin Lab Invest; 2022 Jul; 82(4):334-340. PubMed ID: 35767233 [TBL] [Abstract][Full Text] [Related]
20. Effect of Intralipid infusion on transcutaneous oxygen and carbon dioxide tension in sick neonates. Marks KH; Turner MJ; Rothberg AD S Afr Med J; 1987 Sep; 72(6):389-91. PubMed ID: 3116681 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]