1. Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients.
Li S; Beckman JA; Welch NG; Cheng RK; Rockom SW; Levy WC; O'Brien KD; Dardas TF; Lin S; Leary PJ; Kirkpatrick J; McCabe JM; Bjelkengren J; Chassagne F; Aliseda A; Zimpfer D; Mahr C
ESC Heart Fail; 2020 Dec; 7(6):4241-4246. PubMed ID: 33001579
[TBL] [Abstract][Full Text] [Related]
2. Accuracy of Doppler blood pressure measurement in continuous-flow left ventricular assist device patients.
Li S; Beckman JA; Welch NG; Bjelkengren J; Masri SC; Minami E; Stempien-Otero A; Levy WC; O'Brien KD; Lin S; Farris SD; Cheng RK; Wood G; Koomalsingh K; Kirkpatrick J; McCabe J; Leary PJ; Chassagne F; Chivukula VK; Aliseda A; Mahr C
ESC Heart Fail; 2019 Aug; 6(4):793-798. PubMed ID: 31099483
[TBL] [Abstract][Full Text] [Related]
3. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.
Lanier GM; Orlanes K; Hayashi Y; Murphy J; Flannery M; Te-Frey R; Uriel N; Yuzefpolskaya M; Mancini DM; Naka Y; Takayama H; Jorde UP; Demmer RT; Colombo PC
Circ Heart Fail; 2013 Sep; 6(5):1005-12. PubMed ID: 23811966
[TBL] [Abstract][Full Text] [Related]
4. Noninvasive Measures of Pulsatility and Blood Pressure During Continuous-Flow Left Ventricular Assist Device Support.
Rangasamy S; Madan S; Saeed O; Goldstein DJ; Jorde UP; Negassa A; Patel SR
ASAIO J; 2019; 65(3):241-246. PubMed ID: 29734257
[TBL] [Abstract][Full Text] [Related]
5. Variability in Blood Pressure Assessment in Patients Supported with the HeartMate 3TM.
Cowger JA; Estep JD; Rinde-Hoffman DA; Givertz MM; Anderson AS; Jacoby D; Chen L; Brieke A; Mahr C; Hall S; Ewald GA; Dirckx N; Baker AT; Pinney SP
ASAIO J; 2022 Mar; 68(3):374-383. PubMed ID: 34172641
[TBL] [Abstract][Full Text] [Related]
6. Radial Artery Tonometry to Monitor Blood Pressure and Hemodynamics in Ambulatory Left Ventricular Assist Device Patients in Comparison With Doppler Ultrasound and Transthoracic Echocardiography: A Pilot Study.
Zayat R; Drosos V; Schnoering H; Lee JY; Bleilevens C; Musetti G; Jansen-Park SH; Kang H; Menon AK; Schmitz-Rode T; Autschbach R; Hatam N; Moza A
Artif Organs; 2019 Mar; 43(3):242-253. PubMed ID: 30040134
[TBL] [Abstract][Full Text] [Related]
7. Computational characterization of flow and blood damage potential of the new maglev CH-VAD pump versus the HVAD and HeartMate II pumps.
Zhang J; Chen Z; Griffith BP; Wu ZJ
Int J Artif Organs; 2020 Oct; 43(10):653-662. PubMed ID: 32043405
[TBL] [Abstract][Full Text] [Related]
8. Pulse assessment is important with blood pressure measurement in individuals with continuous flow left ventricular assist devices.
Marcos-Abdala HG; Cruz-Solbes AS; Hussain I; Trachtenberg B; Ashrith G; Torre-Amione G; Bruckner B; Suarez EE; Estep JD; Bhimaraj A
Int J Artif Organs; 2021 Feb; 44(2):124-129. PubMed ID: 32500838
[TBL] [Abstract][Full Text] [Related]
9. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.
Hellman Y; Malik AS; Lane KA; Shen C; Wang IW; Wozniak TC; Hashmi ZA; Munson SD; Pickrell J; Caccamo MA; Gradus-Pizlo I; Hadi A
Artif Organs; 2017 May; 41(5):424-430. PubMed ID: 27782305
[TBL] [Abstract][Full Text] [Related]
10. Pulse Oximeter Usefulness for Blood Pressure Monitoring in Patients Implanted With Latest-Generation Continuous-Flow Device HeartMate 3.
Montalto A; Palermo A; Gherli R; Cammardella A; Contento C; Piazza V; Musumeci F
Transplant Proc; 2019; 51(1):210-214. PubMed ID: 30655160
[TBL] [Abstract][Full Text] [Related]
11. Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices.
Sajgalik P; Kremen V; Fabian V; Maltais S; Stulak JM; Kushwaha SS; Joyce LD; Schirger JA; Johnson BD
ASAIO J; 2019 Feb; 65(2):127-133. PubMed ID: 29538016
[TBL] [Abstract][Full Text] [Related]
12. Do patients with the centrifugal flow HeartMate 3 or HeartWare left ventricular assist device have better outcomes compared to those with axial flow HeartMate II?
Florisson DS; Conte SM; De Bono JA; Newcomb AE
Interact Cardiovasc Thorac Surg; 2019 Dec; 29(6):844-851. PubMed ID: 31436825
[TBL] [Abstract][Full Text] [Related]
13. Accuracy of the CNAP™ monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in pediatric patients weighing 20-40 kilograms.
Kako H; Corridore M; Rice J; Tobias JD
Paediatr Anaesth; 2013 Nov; 23(11):989-93. PubMed ID: 23565770
[TBL] [Abstract][Full Text] [Related]
14. Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device.
Pinsino A; Castagna F; Zuver AM; Royzman EA; Nasiri M; Stöhr EJ; Cagliostro B; McDonnell B; Cockcroft JR; Garan AR; Topkara VK; Schulze PC; Takeda K; Takayama H; Naka Y; Demmer RT; Willey JZ; Yuzefpolskaya M; Colombo PC
J Heart Lung Transplant; 2019 Apr; 38(4):396-405. PubMed ID: 30559034
[TBL] [Abstract][Full Text] [Related]
15. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.
Patel ND; Weiss ES; Schaffer J; Ullrich SL; Rivard DC; Shah AS; Russell SD; Conte JV
Ann Thorac Surg; 2008 Sep; 86(3):832-40; discussion 832-40. PubMed ID: 18721570
[TBL] [Abstract][Full Text] [Related]
16. Automatic non-invasive blood pressure measurement in left ventricular assist device patients with a photoplethysmography assisted device.
Nagy P; Sax B; Kozák A; Merkely B; Osztheimer I; Jobbágy Á
Int J Artif Organs; 2023 May; 46(5):274-279. PubMed ID: 37051689
[TBL] [Abstract][Full Text] [Related]
17. The value of a BP determination method using a novel non-invasive BP device against the invasive catheter measurement.
Xu J; Wu Y; Su H; Hu W; Li J; Wang W; Liu X; Cheng X
PLoS One; 2014; 9(6):e100287. PubMed ID: 24955577
[TBL] [Abstract][Full Text] [Related]
18. Oscillometric measurement of arterial pulse pressure for patients supported by a rotary blood pump.
Yu YC; Peterson A
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():3311-4. PubMed ID: 26737000
[TBL] [Abstract][Full Text] [Related]
19. Noninvasive finger plethysmography for continuous blood pressure monitoring in patients with left ventricular assist device.
Favilla CG; Carter SC; Atluri P; Reehal N; Genuardi MV
Artif Organs; 2023 Sep; 47(9):1472-1478. PubMed ID: 37150940
[TBL] [Abstract][Full Text] [Related]
20. Accuracy of the CNAP monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in the prone position.
Dewhirst E; Corridore M; Klamar J; Beebe A; Rice J; Barry N; Tobias JD
J Clin Anesth; 2013 Jun; 25(4):309-13. PubMed ID: 23685101
[TBL] [Abstract][Full Text] [Related]