These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

414 related articles for article (PubMed ID: 33010100)

  • 1. Impact of baseline conduction abnormalities on outcomes after transcatheter aortic valve replacement with SAPIEN-3.
    Sammour Y; Sato K; Kumar A; Gajulapalli RD; Lak H; Chawla S; Banerjee K; Kaur M; Patel J; Incognito C; Svensson L; Popovic Z; Tarakji K; Wazni O; Reed GW; Yun J; Puri R; Krishnaswamy A; Kapadia SR
    Catheter Cardiovasc Interv; 2021 Jul; 98(1):E127-E138. PubMed ID: 33010100
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical and echocardiographic outcomes with new-onset left bundle branch block after SAPIEN-3 transcatheter aortic valve replacement.
    Sammour YM; Lak H; Chahine J; Abushouk A; Chawla S; Kadri A; Alkhalaileh F; Kumar S; Ghimire B; Svensson L; Popovic Z; Tarakji K; Wazni O; Reed GW; Yun J; Puri R; Krishnaswamy A; Kapadia SR
    Catheter Cardiovasc Interv; 2023 Jan; 101(1):187-196. PubMed ID: 36378620
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A single-centre cohort and short-term follow-up of patients who developed persistent new onset left bundle branch block after transcatheter aortic valve replacement.
    Akdemir B; Roukoz H
    Acta Cardiol; 2020 Aug; 75(4):360-365. PubMed ID: 31984845
    [No Abstract]   [Full Text] [Related]  

  • 4. Long-Term Ventricular Pacing Dependency and Pacemaker Implantation Predictors after Transcatheter Aortic Valve Replacement - A 1-Year Follow-Up.
    Pinto RA; Proença T; Carvalho MM; Pestana G; Lebreiro A; Adão L; Macedo F
    Arq Bras Cardiol; 2022 Oct; 119(4):522-530. PubMed ID: 35857943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New-onset left bundle branch block after transcatheter aortic valve replacement is associated with adverse long-term clinical outcomes in intermediate-risk patients: an analysis from the PARTNER II trial.
    Nazif TM; Chen S; George I; Dizon JM; Hahn RT; Crowley A; Alu MC; Babaliaros V; Thourani VH; Herrmann HC; Smalling RW; Brown DL; Mack MJ; Kapadia S; Makkar R; Webb JG; Leon MB; Kodali SK
    Eur Heart J; 2019 Jul; 40(27):2218-2227. PubMed ID: 31505615
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Outcomes in patients with electrocardiographic left ventricular dyssynchrony following transcatheter aortic valve replacement.
    Ananwattanasuk T; Atreya AR; Teerawongsakul P; Ghannam M; Lathkar-Pradhan S; Latchamsetty R; Jame S; Patel HJ; Grossman PM; Oral H; Jongnarangsin K
    Heart Rhythm; 2023 Jan; 20(1):22-28. PubMed ID: 35948202
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Predictors for new-onset conduction block in patients with pure native aortic regurgitation after transcatheter aortic valve replacement with a new-generation self-expanding valve (VitaFlow Liberty
    Zhang X; Liang C; Zha L; Zuo Q; Hu G; Ding J; Tang S
    BMC Cardiovasc Disord; 2024 Jan; 24(1):77. PubMed ID: 38281925
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictors and 5-Year Clinical Outcomes of Pacemaker After TAVR: Analysis From the PARTNER 2 SAPIEN 3 Registries.
    Chen S; Dizon JM; Hahn RT; Pibarot P; George I; Zhao Y; Blanke P; Kapadia S; Babaliaros V; Szeto WY; Makkar R; Thourani VH; Webb JG; Mack MJ; Leon MB; Kodali S; Nazif TM
    JACC Cardiovasc Interv; 2024 Jun; 17(11):1325-1336. PubMed ID: 38866455
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience.
    Nazif TM; Williams MR; Hahn RT; Kapadia S; Babaliaros V; Rodés-Cabau J; Szeto WY; Jilaihawi H; Fearon WF; Dvir D; Dewey TM; Makkar RR; Xu K; Dizon JM; Smith CR; Leon MB; Kodali SK
    Eur Heart J; 2014 Jun; 35(24):1599-607. PubMed ID: 24179072
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of Preexisting Left Bundle Branch Block in Transcatheter Aortic Valve Replacement Recipients.
    Fischer Q; Himbert D; Webb JG; Eltchaninoff H; Muñoz-García AJ; Tamburino C; Nombela-Franco L; Nietlispach F; Moris C; Ruel M; Dager AE; Serra V; Cheema AN; Amat-Santos IJ; de Brito FS; Ribeiro H; Abizaid A; Sarmento-Leite R; Dumont E; Barbanti M; Durand E; Alonso Briales JH; Bouleti C; Immè S; Maisano F; Del Valle R; Miguel Benitez L; García Del Blanco B; Côté M; Philippon F; Urena M; Rodés-Cabau J
    Circ Cardiovasc Interv; 2018 Nov; 11(11):e006927. PubMed ID: 30571207
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence and Outcomes of New-Onset Right Bundle Branch Block Following Transcatheter Aortic Valve Replacement.
    Tan NY; Adedinsewo D; El Sabbagh A; Sayed Ahmed AF; Carolina Morales-Lara A; Wieczorek M; Madhavan M; Mulpuru SK; Deshmukh AJ; Asirvatham SJ; Eleid MF; Friedman PA; Cha YM; Killu AM
    Circ Arrhythm Electrophysiol; 2024 Feb; 17(2):e012377. PubMed ID: 38288627
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling.
    Dobson LE; Musa TA; Uddin A; Fairbairn TA; Bebb OJ; Swoboda PP; Haaf P; Foley J; Garg P; Fent GJ; Malkin CJ; Blackman DJ; Plein S; Greenwood JP
    J Cardiovasc Magn Reson; 2017 Feb; 19(1):22. PubMed ID: 28222749
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimizing Care of Patients With Right Bundle Branch Block Undergoing Transcatheter Aortic Valve Replacement.
    Kassier A; Velagapudi P; Shrestha NM; Schuitema J; Gauri A; Frost J; Merhi W; Jovinge S; Chalfoun N
    Cardiovasc Revasc Med; 2022 Sep; 42():17-25. PubMed ID: 35398009
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Predictors of Early and Late Atrioventricular Block Requiring Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Single-Center Experience.
    Khan MZ; Gupta A; Franklin S; Abraham A; Jarrar A; Patel KK; Ahmad S; Kutalek S
    Cardiovasc Revasc Med; 2022 Sep; 42():67-71. PubMed ID: 35288044
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical Impact of Baseline Right Bundle Branch Block in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Auffret V; Webb JG; Eltchaninoff H; Muñoz-García AJ; Himbert D; Tamburino C; Nombela-Franco L; Nietlispach F; Morís C; Ruel M; Dager AE; Serra V; Cheema AN; Amat-Santos IJ; de Brito FS; Lemos PA; Abizaid A; Sarmento-Leite R; Dumont E; Barbanti M; Durand E; Alonso Briales JH; Vahanian A; Bouleti C; Immè S; Maisano F; Del Valle R; Benitez LM; García Del Blanco B; Puri R; Philippon F; Urena M; Rodés-Cabau J
    JACC Cardiovasc Interv; 2017 Aug; 10(15):1564-1574. PubMed ID: 28734885
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Predicting need for pacemaker implantation early and late after transcatheter aortic valve implantation.
    Mazzella AJ; Sanders M; Yang H; Li Q; Vavalle JP; Gehi A
    Catheter Cardiovasc Interv; 2021 Mar; 97(4):E588-E596. PubMed ID: 32857905
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prophylactic permanent pacemaker strategy in patients with right bundle branch block undergoing transcatheter aortic valve replacement.
    Fukutomi M; Hokken T; Wong I; Bieliauskas G; Daemen J; de Jaegere P; Van Mieghem N; Søndergaard L; De Backer O
    Catheter Cardiovasc Interv; 2021 Dec; 98(7):E1017-E1025. PubMed ID: 34390167
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computed tomography (CT) assessment of the membranous septal anatomy prior to transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 valve.
    Oestreich BA; Mbai M; Gurevich S; Nijjar PS; Adabag S; Bertog S; Kelly R; Garcia S
    Cardiovasc Revasc Med; 2018; 19(5 Pt B):626-631. PubMed ID: 29352699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.