172 related articles for article (PubMed ID: 33012478)
1. Accuracy and Reliability of a Disposable Vascular Pressure Device for Arterial Pressure Monitoring in Critical Care Transport.
Schmid KM; Lauria MJ; Braude DA; Crandall CS; Marinaro JL
Air Med J; 2020; 39(5):389-392. PubMed ID: 33012478
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of a Disposable Vascular Pressure Device for Pre- and Postmembrane Pressure Monitoring During Venovenous Extracorporeal Membrane Oxygenation.
Lauria MJ; Shaffer J; Crandall CS; Marinaro JL
ASAIO J; 2022 Nov; 68(11):1352-1357. PubMed ID: 36326699
[TBL] [Abstract][Full Text] [Related]
3. The Accuracy of the CNAP® Device Compared with Invasive Radial Artery Measurements for Providing Continuous Noninvasive Arterial Blood Pressure Readings at a Medical Intensive Care Unit: A Method-Comparison Study.
Smolle KH; Schmid M; Prettenthaler H; Weger C
Anesth Analg; 2015 Dec; 121(6):1508-16. PubMed ID: 26496367
[TBL] [Abstract][Full Text] [Related]
4. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure.
Meidert AS; Huber W; Müller JN; Schöfthaler M; Hapfelmeier A; Langwieser N; Wagner JY; Eyer F; Schmid RM; Saugel B
Br J Anaesth; 2014 Mar; 112(3):521-8. PubMed ID: 24355832
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome.
Meidert AS; Huber W; Hapfelmeier A; Schöfthaler M; Müller JN; Langwieser N; Wagner JY; Schmid RM; Saugel B
J Crit Care; 2013 Dec; 28(6):908-12. PubMed ID: 23910893
[TBL] [Abstract][Full Text] [Related]
6. The CNAP™ Finger Cuff for Noninvasive Beat-To-Beat Monitoring of Arterial Blood Pressure: An Evaluation in Intensive Care Unit Patients and a Comparison with 2 Intermittent Devices.
Lakhal K; Martin M; Faiz S; Ehrmann S; Blanloeil Y; Asehnoune K; Rozec B; Boulain T
Anesth Analg; 2016 Nov; 123(5):1126-1135. PubMed ID: 27159068
[TBL] [Abstract][Full Text] [Related]
7. Prehospital Invasive Arterial Pressure: Use of a Minimized Flush System.
Karlsson J; Linde J; Svensen C; Gellerfors M
Prehosp Disaster Med; 2018 Oct; 33(5):490-494. PubMed ID: 30168412
[TBL] [Abstract][Full Text] [Related]
8. Continuous Noninvasive Arterial Pressure Monitoring in Obese Patients During Bariatric Surgery: An Evaluation of the Vascular Unloading Technique (Clearsight system).
Rogge DE; Nicklas JY; Schön G; Grothe O; Haas SA; Reuter DA; Saugel B
Anesth Analg; 2019 Mar; 128(3):477-483. PubMed ID: 30649073
[TBL] [Abstract][Full Text] [Related]
9. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.
Langwieser N; Prechtl L; Meidert AS; Hapfelmeier A; Bradaric C; Ibrahim T; Laugwitz KL; Schmid RM; Wagner JY; Saugel B
Clin Res Cardiol; 2015 Jun; 104(6):518-24. PubMed ID: 25618259
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of Noninvasive Blood Pressure Monitoring in Critically Ill Adults.
Haber EN; Sonti R; Simkovich SM; Pike CW; Boxley CL; Fong A; Weintraub WS; Cobb NK
J Intensive Care Med; 2024 Jul; 39(7):665-671. PubMed ID: 38215002
[No Abstract] [Full Text] [Related]
11. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device.
Saugel B; Meidert AS; Hapfelmeier A; Eyer F; Schmid RM; Huber W
Br J Anaesth; 2013 Aug; 111(2):185-90. PubMed ID: 23491946
[TBL] [Abstract][Full Text] [Related]
12. Continuous Non-invasive finger cuff CareTaker® comparable to invasive intra-arterial pressure in patients undergoing major intra-abdominal surgery.
Gratz I; Deal E; Spitz F; Baruch M; Allen IE; Seaman JE; Pukenas E; Jean S
BMC Anesthesiol; 2017 Mar; 17(1):48. PubMed ID: 28327093
[TBL] [Abstract][Full Text] [Related]
13. Comparison of a continuous noninvasive arterial pressure device with invasive measurements in cardiovascular postsurgical intensive care patients: a prospective observational study.
Ilies C; Grudev G; Hedderich J; Renner J; Steinfath M; Bein B; Haake N; Hanss R
Eur J Anaesthesiol; 2015 Jan; 32(1):20-8. PubMed ID: 25105850
[TBL] [Abstract][Full Text] [Related]
14. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients.
Hohn A; Defosse JM; Becker S; Steffen C; Wappler F; Sakka SG
Br J Anaesth; 2013 Aug; 111(2):178-84. PubMed ID: 23485882
[TBL] [Abstract][Full Text] [Related]
15. Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors.
Gardner RM
Crit Care Med; 1996 May; 24(5):879-82. PubMed ID: 8706469
[TBL] [Abstract][Full Text] [Related]
16. Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department.
Wagner JY; Prantner JS; Meidert AS; Hapfelmeier A; Schmid RM; Saugel B
Scand J Trauma Resusc Emerg Med; 2014 Jan; 22():8. PubMed ID: 24472659
[TBL] [Abstract][Full Text] [Related]
17. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.
Lanier GM; Orlanes K; Hayashi Y; Murphy J; Flannery M; Te-Frey R; Uriel N; Yuzefpolskaya M; Mancini DM; Naka Y; Takayama H; Jorde UP; Demmer RT; Colombo PC
Circ Heart Fail; 2013 Sep; 6(5):1005-12. PubMed ID: 23811966
[TBL] [Abstract][Full Text] [Related]
18. The stability of arterial blood gases during transportation of patients using the RespirTech PRO.
Romano M; Raabe OG; Walby W; Albertson TE
Am J Emerg Med; 2000 May; 18(3):273-7. PubMed ID: 10830683
[TBL] [Abstract][Full Text] [Related]
19. The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients.
Saugel B; Fassio F; Hapfelmeier A; Meidert AS; Schmid RM; Huber W
Intensive Care Med; 2012 Sep; 38(9):1471-7. PubMed ID: 22744376
[TBL] [Abstract][Full Text] [Related]
20. Hemodynamic Monitoring In The Cardiac Surgical Patient: Comparison of Three Arterial Catheters.
Bui D; Hayward G; Chen TH; Apruzzese P; Asher S; Maslow M; Gorgone M; Hunter C; Flaherty D; Kendall M; Maslow A
J Cardiothorac Vasc Anesth; 2024 May; 38(5):1115-1126. PubMed ID: 38461034
[TBL] [Abstract][Full Text] [Related]