183 related articles for article (PubMed ID: 33012808)
1. Enhancing sensitivity of lateral flow assay with application to SARS-CoV-2.
Peng T; Liu X; Adams LG; Agarwal G; Akey B; Cirillo J; Deckert V; Delfan S; Fry E; Han Z; Hemmer P; Kattawar G; Kim M; Lee MC; Lu C; Mogford J; Nessler R; Neuman B; Nie X; Pan J; Pryor J; Rajil N; Shih Y; Sokolov A; Svidzinsky A; Wang D; Yi Z; Zheltikov A; Scully M
Appl Phys Lett; 2020 Sep; 117(12):120601. PubMed ID: 33012808
[TBL] [Abstract][Full Text] [Related]
2. fM-aM Detection of the SARS-CoV-2 Antigen by Advanced Lateral Flow Immunoassay Based on Gold Nanospheres.
Liu Y; Zhan L; Shen JW; Baro B; Alemany A; Sackrison J; Mitjà O; Bischof JC
ACS Appl Nano Mater; 2021 Dec; 4(12):13826-13837. PubMed ID: 34957379
[TBL] [Abstract][Full Text] [Related]
3. Nanoarchitectonics of photothermal materials to enhance the sensitivity of lateral flow assays.
Sarathkumar E; Anjana RS; Jayasree RS
Beilstein J Nanotechnol; 2023; 14():988-1003. PubMed ID: 37822722
[TBL] [Abstract][Full Text] [Related]
4. Plasmon-enhanced Quantitative Lateral Flow Assay for Femtomolar Detection of SARS-CoV-2 Antibodies and Antigens.
Gupta R; Gupta P; Wang Z; Seth A; Morrissey J; George I; Gandra S; Storch G; Parikh B; Genin G; Singamaneni S
Res Sq; 2022 Feb; ():. PubMed ID: 35194598
[TBL] [Abstract][Full Text] [Related]
5. Highly sensitive paper-based immunoassay using photothermal laser speckle imaging.
Song S; Choi S; Ryu S; Kim S; Kim T; Shin J; Jung HI; Joo C
Biosens Bioelectron; 2018 Oct; 117():385-391. PubMed ID: 29960270
[TBL] [Abstract][Full Text] [Related]
6. Rapid Detection of IgM Antibodies against the SARS-CoV-2 Virus via Colloidal Gold Nanoparticle-Based Lateral-Flow Assay.
Huang C; Wen T; Shi FJ; Zeng XY; Jiao YJ
ACS Omega; 2020 Jun; 5(21):12550-12556. PubMed ID: 32542208
[TBL] [Abstract][Full Text] [Related]
7. Lateral flow assay with near-infrared dye for multiplex detection.
Swanson C; D'Andrea A
Clin Chem; 2013 Apr; 59(4):641-8. PubMed ID: 23364182
[TBL] [Abstract][Full Text] [Related]
8. Recent Advances in Silica-Nanomaterial-Assisted Lateral Flow Assay.
Zhuang H; Xu C; Gao F; Li Y; Lei C; Yu C
Bioengineering (Basel); 2022 Jun; 9(7):. PubMed ID: 35877318
[TBL] [Abstract][Full Text] [Related]
9. Effect of sample volume on the sensitivity of lateral flow assays through computational modeling.
Xia G; Wang J; Liu Z; Bai L; Ma L
Anal Biochem; 2021 Apr; 619():114130. PubMed ID: 33600781
[TBL] [Abstract][Full Text] [Related]
10. Lateral flow assay ruler for quantitative and rapid point-of-care testing.
Li Z; Chen H; Wang P
Analyst; 2019 May; 144(10):3314-3322. PubMed ID: 30968883
[TBL] [Abstract][Full Text] [Related]
11. Sensitivity enhancement in lateral flow assays: a systems perspective.
Bishop JD; Hsieh HV; Gasperino DJ; Weigl BH
Lab Chip; 2019 Jul; 19(15):2486-2499. PubMed ID: 31251312
[TBL] [Abstract][Full Text] [Related]
12. Development of a competitive double antibody lateral flow assay for the detection of antibodies specific to glycoprotein B of Aujeszky's disease virus in swine sera.
Vrublevskaya VV; Afanasyev VN; Grinevich AA; Skarga YY; Gladyshev PP; Ibragimova SA; Krylsky DV; Morenkov OS
J Virol Methods; 2017 Feb; 240():54-62. PubMed ID: 27894861
[TBL] [Abstract][Full Text] [Related]
13. Polydimethylsiloxane-Paper Hybrid Lateral Flow Assay for Highly Sensitive Point-of-Care Nucleic Acid Testing.
Choi JR; Liu Z; Hu J; Tang R; Gong Y; Feng S; Ren H; Wen T; Yang H; Qu Z; Pingguan-Murphy B; Xu F
Anal Chem; 2016 Jun; 88(12):6254-64. PubMed ID: 27012657
[TBL] [Abstract][Full Text] [Related]
14. An Aqueous Two-Phase System for the Concentration and Extraction of Proteins from the Interface for Detection Using the Lateral-Flow Immunoassay.
Chiu RY; Thach AV; Wu CM; Wu BM; Kamei DT
PLoS One; 2015; 10(11):e0142654. PubMed ID: 26556593
[TBL] [Abstract][Full Text] [Related]
15. Clinical Utility of a Highly Sensitive Lateral Flow Immunoassay as determined by Titer Analysis for the Detection of anti-SARS-CoV-2 Antibodies at the Point-of-Care.
Haymond A; Mueller C; Steinberg H; Hodge KA; Lehman CW; Lin SC; Collini L; Branscome H; Nguyen TV; Rucker S; Panny L; Flor R; Guirguis R; Hoefer R; Lorenzin G; Petricoin E; Kashanchi F; Kehn-Hall K; Lanzafame P; Liotta L; Luchini A
medRxiv; 2020 Aug; ():. PubMed ID: 32766594
[TBL] [Abstract][Full Text] [Related]
16. Detection of viruses by counting single fluorescent genetically biotinylated reporter immunophage using a lateral flow assay.
Kim J; Adhikari M; Dhamane S; Hagström AE; Kourentzi K; Strych U; Willson RC; Conrad JC
ACS Appl Mater Interfaces; 2015 Feb; 7(4):2891-8. PubMed ID: 25581289
[TBL] [Abstract][Full Text] [Related]
17. Recent advances in sensitivity enhancement for lateral flow assay.
Deng Y; Jiang H; Li X; Lv X
Mikrochim Acta; 2021 Oct; 188(11):379. PubMed ID: 34647157
[TBL] [Abstract][Full Text] [Related]
18. Lateral flow assays.
Koczula KM; Gallotta A
Essays Biochem; 2016 Jun; 60(1):111-20. PubMed ID: 27365041
[TBL] [Abstract][Full Text] [Related]
19. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay.
Yan C; Cui J; Huang L; Du B; Chen L; Xue G; Li S; Zhang W; Zhao L; Sun Y; Yao H; Li N; Zhao H; Feng Y; Liu S; Zhang Q; Liu D; Yuan J
Clin Microbiol Infect; 2020 Jun; 26(6):773-779. PubMed ID: 32276116
[TBL] [Abstract][Full Text] [Related]
20. Lateral flow assay with pressure meter readout for rapid point-of-care detection of disease-associated protein.
Lin B; Guan Z; Song Y; Song E; Lu Z; Liu D; An Y; Zhu Z; Zhou L; Yang C
Lab Chip; 2018 Mar; 18(6):965-970. PubMed ID: 29479611
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]