62 related articles for article (PubMed ID: 33016342)
1. Near-Infrared Fluorescence Imaging in the Identification of Parathyroid Glands in Thyroidectomy.
Takahashi T; Yamazaki K; Ota H; Shodo R; Ueki Y; Horii A
Laryngoscope; 2021 May; 131(5):1188-1193. PubMed ID: 33016342
[TBL] [Abstract][Full Text] [Related]
2. Feasibility of Autofluorescence Using Overlay Imaging for the Detection of Parathyroid Glands: Defining Standards.
Arikan M; Hegazy J; Mertlitsch S; Binter T; Hargitai L; Scheuba C; Riss P
Ann Surg Oncol; 2024 Feb; 31(2):1116-1124. PubMed ID: 37957502
[TBL] [Abstract][Full Text] [Related]
3. Near-infrared autofluorescence imaging to detect parathyroid glands in thyroid surgery.
Ladurner R; Al Arabi N; Guendogar U; Hallfeldt K; Stepp H; Gallwas J
Ann R Coll Surg Engl; 2018 Jan; 100(1):33-36. PubMed ID: 29022781
[TBL] [Abstract][Full Text] [Related]
4. Intraoperative strategies in identification and functional protection of parathyroid glands for patients with thyroidectomy: a systematic review and network meta-analysis.
Lu D; Pan B; Tang E; Yin S; Sun Y; Yuan Y; Yin T; Yang Z; Zhang F
Int J Surg; 2024 Mar; 110(3):1723-1734. PubMed ID: 38079585
[TBL] [Abstract][Full Text] [Related]
5. Factors affecting the rates of incidental parathyroidectomy during thyroidectomy.
Arslan HE; Zeren S; Yildirim AC; Ekici MF; Arik O; Algin MC
Ann R Coll Surg Engl; 2024 May; 106(5):454-460. PubMed ID: 38445585
[TBL] [Abstract][Full Text] [Related]
6. A novel optical approach to intraoperative detection of parathyroid glands.
McWade MA; Paras C; White LM; Phay JE; Mahadevan-Jansen A; Broome JT
Surgery; 2013 Dec; 154(6):1371-7; discussion 1377. PubMed ID: 24238054
[TBL] [Abstract][Full Text] [Related]
7. ASO Author Reflections: Realtime Near-infrared Autofluorescence Based Overlay Imaging as Intraoperative Tool for Parathyroid Gland Localization: Routinized Application and Standards in Clinical Practice.
Arikan M; Hegazy J; Mertlitsch S; Binter T; Hargitai L; Scheuba C; Riss P
Ann Surg Oncol; 2024 Feb; 31(2):1138-1139. PubMed ID: 38082167
[No Abstract] [Full Text] [Related]
8. High Rates of Discordant Ureteral Perfusion During Open Ureteral Reconstruction With Indocyanine Green: Does Near-Infrared Fluorescence Imaging Change Management or Stricture Outcomes?
Hebert KJ; Bearrick E; Anderson KT; Viers BR
Urology; 2024 May; ():. PubMed ID: 38754791
[TBL] [Abstract][Full Text] [Related]
9. Comparative Study between the Surgeon's Intraoperative Evaluation and Histopathology for Diagnosis of Laryngeal Lesions.
von Stülpnagel B; Hagen R; Olzowy B; Witt G; Pau HW; Just T
Int Sch Res Notices; 2014; 2014():635251. PubMed ID: 27419206
[TBL] [Abstract][Full Text] [Related]
10. Communication in your department and beyond.
Riall TS; Worrell SG
Surgery; 2024 Apr; 175(4):1237-1239. PubMed ID: 38049361
[TBL] [Abstract][Full Text] [Related]
11. Are Poor Outcomes Always a Surgeon's Complication?
Aghaloo T
J Oral Maxillofac Surg; 2024 May; 82(5):507-508. PubMed ID: 38697687
[No Abstract] [Full Text] [Related]
12. A Surgeon's Perspective From the Sharp End of Surgical Innovation.
McKneally MF
Am J Bioeth; 2024 May; 24(5):79-81. PubMed ID: 38635439
[No Abstract] [Full Text] [Related]
13. 'As His was Not a Surgical Case it was Not My Duty to Attend Him': The Surgeon's Role in the Nineteenth-Century Royal Dockyards.
Biddle R
Med Hist; 2013 Oct; 57(4):559-78. PubMed ID: 24069917
[TBL] [Abstract][Full Text] [Related]
14. A Surgeon's Thoughts on Anæsthetics.
Gamgee L
Proc R Soc Med; 1924; 17(Sect Anaesth):11-6. PubMed ID: 19983936
[No Abstract] [Full Text] [Related]
15. Navigating the Future of Spine Surgery: A Surgeon's Reflection on Coding, Reimbursement, and Emerging Technologies.
Lorio MP
Int J Spine Surg; 2024 May; 18(2):120-121. PubMed ID: 38580451
[No Abstract] [Full Text] [Related]
16. Intraoperative near-infrared imaging of parathyroid glands: A comparison of first- and second-generation technologies.
Akbulut S; Erten O; Gokceimam M; Kim YS; Krishnamurthy V; Heiden K; Jin J; Siperstein A; Berber E
J Surg Oncol; 2021 Mar; 123(4):866-871. PubMed ID: 33333584
[TBL] [Abstract][Full Text] [Related]
17. Current state of intraoperative use of near infrared fluorescence for parathyroid identification and preservation.
Solórzano CC; Thomas G; Berber E; Wang TS; Randolph GW; Duh QY; Triponez F
Surgery; 2021 Apr; 169(4):868-878. PubMed ID: 33139065
[TBL] [Abstract][Full Text] [Related]
18. The effect of intraoperative autofluorescence monitoring on unintentional parathyroid gland excision rates and postoperative PTH concentrations-a single-blind randomized-controlled trial.
Papavramidis TS; Chorti A; Tzikos G; Anagnostis P; Pantelidis P; Pliakos I; Panidis S; Papaioannou M; Bakkar S; Unal E; Michalopoulos A
Endocrine; 2021 May; 72(2):546-552. PubMed ID: 33432503
[TBL] [Abstract][Full Text] [Related]
19. In Response to Regarding Near-Infrared Fluorescence Imaging in the Identification of Parathyroid Glands in Thyroidectomy.
Takahashi T; Yamazaki K; Ota H; Shodo R; Ueki Y; Horii A
Laryngoscope; 2021 May; 131(5):E1749. PubMed ID: 33538331
[No Abstract] [Full Text] [Related]
20. Comparison of Autofluorescence With Near-Infrared Fluorescence Imaging Between Primary and Secondary Hyperparathyroidism.
Takeuchi M; Takahashi T; Shodo R; Ota H; Ueki Y; Yamazaki K; Horii A
Laryngoscope; 2021 Jun; 131(6):E2097-E2104. PubMed ID: 33305844
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]