These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 33016670)

  • 1. [Implantable loop recorders for prolonged heart-rhythm monitoring in patients with cryptogenic stroke].
    Nikolaeva OA; Sapelnikov OV; Grishin IR; Cherkashin DI; Ardus DF; Kulikov AA; Uskach TM; Akchurin RS
    Zh Nevrol Psikhiatr Im S S Korsakova; 2020; 120(8. Vyp. 2):5-9. PubMed ID: 33016670
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extended ECG monitoring with an implantable loop recorder in patients with cryptogenic stroke: time schedule, reasons for explantation and incidental findings (results from the TRACK-AF trial).
    Bettin M; Dechering D; Kochhäuser S; Bode N; Eckardt L; Frommeyer G; Reinke F
    Clin Res Cardiol; 2019 Mar; 108(3):309-314. PubMed ID: 30167809
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [High performance of an implantable Holter monitor in the detection of concealed paroxysmal atrial fibrillation in patients with cryptogenic stroke and a suspected embolic mechanism].
    Rojo-Martinez E; Sandín-Fuentes M; Calleja-Sanz AI; Cortijo-García E; García-Bermejo P; Ruiz-Piñero M; Rubio-Sanz J; Arenillas-Lara JF
    Rev Neurol; 2013 Sep; 57(6):251-7. PubMed ID: 24008935
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implantable loop recorder monitoring in patients with cryptogenic stroke - Detection and treatment of different clinically relevant arrhythmias.
    Pecha S; Wilke I; Yildirim Y; Reichenspurner H; Aydin MA
    J Electrocardiol; 2020; 60():102-106. PubMed ID: 32339814
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Meta-Analysis of Randomized Clinical Trials Comparing the Impact of Implantable Loop Recorder Versus Usual Care After Ischemic Stroke for Detection of Atrial Fibrillation and Stroke Risk.
    Ko D; Dai Q; Flynn DB; Bosch NA; Helm RH; Monahan KM; Andersson C; Anderson CD; Walkey AJ
    Am J Cardiol; 2022 Jan; 162():100-104. PubMed ID: 34756594
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Incidence of false-positive transmissions during remote rhythm monitoring with implantable loop recorders.
    Afzal MR; Mease J; Koppert T; Okabe T; Tyler J; Houmsse M; Augostini RS; Weiss R; Hummel JD; Kalbfleisch SJ; Daoud EG
    Heart Rhythm; 2020 Jan; 17(1):75-80. PubMed ID: 31323348
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Contemporary Practice and Optimising Referral Pathways for Implantable Cardiac Monitoring for Atrial Fibrillation after Cryptogenic Stroke.
    Ahluwalia N; Graham A; Honarbakhsh S; Tarkas T; Martin S; Monkhouse C; Finlay M; Earley MJ; Icart R; Spooner O; Chandratheva A; Schilling RJ
    J Stroke Cerebrovasc Dis; 2022 Jul; 31(7):106474. PubMed ID: 35544977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cryptogenic ischemic stroke and prevalence of asymptomatic atrial fibrillation: a prospective study.
    Jorfida M; Antolini M; Cerrato E; Caprioli MG; Castagno D; Garrone P; Budano C; Cerrato P; Gaita F
    J Cardiovasc Med (Hagerstown); 2016 Dec; 17(12):863-869. PubMed ID: 25379716
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Implantable vs Prolonged External Electrocardiographic Monitoring on Atrial Fibrillation Detection in Patients With Ischemic Stroke: The PER DIEM Randomized Clinical Trial.
    Buck BH; Hill MD; Quinn FR; Butcher KS; Menon BK; Gulamhusein S; Siddiqui M; Coutts SB; Jeerakathil T; Smith EE; Khan K; Barber PA; Jickling G; Reyes L; Save S; Fairall P; Piquette L; Kamal N; Chew DS; Demchuk AM; Shuaib A; Exner DV
    JAMA; 2021 Jun; 325(21):2160-2168. PubMed ID: 34061146
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Immediate implantable loop recorder implantation for detecting atrial fibrillation in cryptogenic stroke.
    Dulai R; Hunt J; Veasey RA; Biyanwila C; O'Neill B; Patel N
    J Stroke Cerebrovasc Dis; 2023 Mar; 32(3):106988. PubMed ID: 36645969
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of atrial fibrillation by implantable loop recorders following cryptogenic stroke: A retrospective study of predictive factors and outcomes.
    Samaan S; Kohli U; Nazeer B; Stoute H; Zhao W; Szpunar SM; Azzo Z; Hassan S
    J Electrocardiol; 2022; 71():54-58. PubMed ID: 35176666
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the Effect of Atrial Fibrillation Detection Algorithms in Patients With Cryptogenic Stroke Using Implantable Loop Recorders.
    Chorin E; Peterson C; Kogan E; Barbhaiya C; Aizer A; Holmes D; Bernstein S; Schole M; Duraiswami H; Spinelli M; Park D; Chinitz L; Jankelson L
    Am J Cardiol; 2020 Aug; 129():25-29. PubMed ID: 32600783
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Economic evaluation of extended electrocardiogram monitoring for atrial fibrillation in patients with cryptogenic stroke.
    Chew DS; Rennert-May E; Quinn FR; Buck B; Hill MD; Spackman E; Manns BJ; Exner DV
    Int J Stroke; 2021 Oct; 16(7):809-817. PubMed ID: 33232196
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detection of atrial fibrillation in real world setting in patients with cryptogenic stroke and an implantable loop recorder.
    Kim SE; Khawaja M; Kim JA; Safavi-Naeini P; Pickett J; Molina-Razavi J; Saeed M; Razavi M; Rasekh A; Chelu M
    Pacing Clin Electrophysiol; 2023 Jul; 46(7):788-795. PubMed ID: 37323035
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of atrial fibrillation using an implantable loop recorder in patients with previous cryptogenic stroke: the SPIDER-AF registry (Stroke Prevention by Increasing DEtection Rates of Atrial Fibrillation).
    Rybak K; D Ancona G; Glück S; Haerer W; Goss F;
    Clin Res Cardiol; 2023 Dec; 112(12):1848-1859. PubMed ID: 37610472
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Detection of atrial fibrillation in patients with embolic stroke of undetermined source by prolonged monitoring with implantable loop recorders.
    Israel C; Kitsiou A; Kalyani M; Deelawar S; Ejangue LE; Rogalewski A; Hagemeister C; Minnerup J; Schäbitz WR
    Thromb Haemost; 2017 Oct; 117(10):1962-1969. PubMed ID: 28862284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of atrial fibrillation using an implantable loop recorder following cryptogenic stroke: implications for post-stroke electrocardiographic monitoring.
    Milstein NS; Musat DL; Allred J; Seiler A; Pimienta J; Oliveros S; Bhatt AG; Preminger M; Sichrovsky T; Shaw RE; Mittal S
    J Interv Card Electrophysiol; 2020 Jan; 57(1):141-147. PubMed ID: 31612300
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implantable Loop Recorders-Syncope, Cryptogenic Stroke, Atrial Fibrillation.
    Mittal S
    Card Electrophysiol Clin; 2021 Sep; 13(3):439-447. PubMed ID: 34330371
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effectiveness, utilisation and cost associated with implantable loop recorders versus external monitors after ischaemic or cryptogenic stroke.
    Dhruva SS; Murillo J; Ameli O; Chaisson CE; Redberg RF; Cohen K
    Open Heart; 2024 May; 11(1):. PubMed ID: 38719499
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The utility of implantable loop recorders in patient management: an age- and indication-stratified study in the outpatient-implant era.
    Sanghvi MM; Jones DM; Kalindjian J; Monkhouse C; Providencia R; Schilling RJ; Ahluwalia N; Earley MJ; Finlay M
    Eur Heart J Qual Care Clin Outcomes; 2022 Oct; 8(7):770-777. PubMed ID: 34601557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.