1. Motor unit filter prelearning strategies for decomposition of compound muscle action potentials in high-density surface electromyograms. Holobar A; Francic A Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3465-3468. PubMed ID: 33018749 [TBL] [Abstract][Full Text] [Related]
2. Decoding firings of a large population of human motor units from high-density surface electromyogram in response to transcranial magnetic stimulation. Škarabot J; Ammann C; Balshaw TG; Divjak M; Urh F; Murks N; Foffani G; Holobar A J Physiol; 2023 May; 601(10):1719-1744. PubMed ID: 36946417 [TBL] [Abstract][Full Text] [Related]
3. Motor Unit Identification From High-Density Surface Electromyograms in Repeated Dynamic Muscle Contractions. Glaser V; Holobar A IEEE Trans Neural Syst Rehabil Eng; 2019 Jan; 27(1):66-75. PubMed ID: 30571641 [TBL] [Abstract][Full Text] [Related]
4. Motor Unit Identification in the M Waves Recorded by High-Density Electromyogram. Kalc M; Skarabot J; Divjak M; Urh F; Kramberger M; Vogrin M; Holobar A IEEE Trans Biomed Eng; 2023 May; 70(5):1662-1672. PubMed ID: 36441888 [TBL] [Abstract][Full Text] [Related]
5. Simulations of high-density surface electromyograms in dynamic muscle contractions. Glaser V; Farina D; Holobar A Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():3453-3456. PubMed ID: 29060640 [TBL] [Abstract][Full Text] [Related]
6. Correlation-based decomposition of surface electromyograms at low contraction forces. Holobar A; Zazula D Med Biol Eng Comput; 2004 Jul; 42(4):487-95. PubMed ID: 15320457 [TBL] [Abstract][Full Text] [Related]
7. Identification of Motor Unit Firings in H-Reflex of Soleus Muscle Recorded by High-Density Surface Electromyography. Kalc M; Skarabot J; Divjak M; Urh F; Kramberger M; Vogrin M; Holobar A IEEE Trans Neural Syst Rehabil Eng; 2023; 31():119-129. PubMed ID: 36315546 [TBL] [Abstract][Full Text] [Related]
8. On the impact of spike segmentation on motor unit identification in dynamic surface electromyograms. Glaser V; Holobar A Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():430-433. PubMed ID: 29059902 [TBL] [Abstract][Full Text] [Related]
9. Single channel surface electromyogram deconvolution to explore motor unit discharges. Mesin L Med Biol Eng Comput; 2019 Sep; 57(9):2045-2054. PubMed ID: 31350669 [TBL] [Abstract][Full Text] [Related]
10. The effect of rate of torque development on motor unit recruitment and firing rates during isometric voluntary trapezoidal contractions. Miller JD; Lund CJ; Gingrich MD; Schtul KL; Wray ME; Herda TJ Exp Brain Res; 2019 Oct; 237(10):2653-2664. PubMed ID: 31396644 [TBL] [Abstract][Full Text] [Related]
11. Motor unit recruitment and rate coding in response to fatiguing shoulder abductions and subsequent recovery. Jensen BR; Pilegaard M; Sjøgaard G Eur J Appl Physiol; 2000 Oct; 83(2-3):190-9. PubMed ID: 11104060 [TBL] [Abstract][Full Text] [Related]
12. Inter-operator agreement in decomposition of motor unit firings from high-density surface EMG. Kleine BU; van Dijk JP; Zwarts MJ; Stegeman DF J Electromyogr Kinesiol; 2008 Aug; 18(4):652-61. PubMed ID: 17363274 [TBL] [Abstract][Full Text] [Related]
13. Firing rates of motor units during strong dynamic contractions. Del Valle A; Thomas CK Muscle Nerve; 2005 Sep; 32(3):316-25. PubMed ID: 15973658 [TBL] [Abstract][Full Text] [Related]
14. Synchronization of motor-unit firings in several human muscles. De Luca CJ; Roy AM; Erim Z J Neurophysiol; 1993 Nov; 70(5):2010-23. PubMed ID: 8294967 [TBL] [Abstract][Full Text] [Related]
15. Magnetic stimulation-induced modulations of motor unit firings extracted from multi-channel surface EMG. Kleine BU; Blok JH; Oostenveld R; Praamstra P; Stegeman DF Muscle Nerve; 2000 Jul; 23(7):1005-15. PubMed ID: 10882994 [TBL] [Abstract][Full Text] [Related]
16. Motor unit recruitment pattern during low-level static and dynamic contractions. Søgaard K Muscle Nerve; 1995 Mar; 18(3):292-300. PubMed ID: 7870106 [TBL] [Abstract][Full Text] [Related]
17. The compensatory interaction between motor unit firing behavior and muscle force during fatigue. Contessa P; De Luca CJ; Kline JC J Neurophysiol; 2016 Oct; 116(4):1579-1585. PubMed ID: 27385798 [TBL] [Abstract][Full Text] [Related]
18. Physical and electrophysiological motor unit characteristics are revealed with simultaneous high-density electromyography and ultrafast ultrasound imaging. Carbonaro M; Meiburger KM; Seoni S; Hodson-Tole EF; Vieira T; Botter A Sci Rep; 2022 May; 12(1):8855. PubMed ID: 35614312 [TBL] [Abstract][Full Text] [Related]
19. Correlation between discharge timings of pairs of motor units reveals the presence but not the proportion of common synaptic input to motor neurons. Rodriguez-Falces J; Negro F; Farina D J Neurophysiol; 2017 Apr; 117(4):1749-1760. PubMed ID: 28100652 [TBL] [Abstract][Full Text] [Related]
20. Effect of experimental muscle pain on motor unit firing rate and conduction velocity. Farina D; Arendt-Nielsen L; Merletti R; Graven-Nielsen T J Neurophysiol; 2004 Mar; 91(3):1250-9. PubMed ID: 14614105 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]