203 related articles for article (PubMed ID: 33018767)
1. Temporally Interfering TMS: Focal and Dynamic Stimulation Location.
Sorkhabi MM; Wendt K; Denison T
Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3537-3543. PubMed ID: 33018767
[TBL] [Abstract][Full Text] [Related]
2. Design of transcranial magnetic stimulation coils with optimal trade-off between depth, focality, and energy.
Gomez LJ; Goetz SM; Peterchev AV
J Neural Eng; 2018 Aug; 15(4):046033. PubMed ID: 29855433
[TBL] [Abstract][Full Text] [Related]
3. Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs.
Deng ZD; Lisanby SH; Peterchev AV
Brain Stimul; 2013 Jan; 6(1):1-13. PubMed ID: 22483681
[TBL] [Abstract][Full Text] [Related]
4. Evaluation method for in situ electric field in standardized human brain for different transcranial magnetic stimulation coils.
Iwahashi M; Gomez-Tames J; Laakso I; Hirata A
Phys Med Biol; 2017 Mar; 62(6):2224-2238. PubMed ID: 28222046
[TBL] [Abstract][Full Text] [Related]
5. Database of 25 validated coil models for electric field simulations for TMS.
Drakaki M; Mathiesen C; Siebner HR; Madsen K; Thielscher A
Brain Stimul; 2022; 15(3):697-706. PubMed ID: 35490970
[TBL] [Abstract][Full Text] [Related]
6. Minimum-energy coils for transcranial magnetic stimulation: application to focal stimulation.
Koponen LM; Nieminen JO; Ilmoniemi RJ
Brain Stimul; 2015; 8(1):124-34. PubMed ID: 25458713
[TBL] [Abstract][Full Text] [Related]
7. Trade-off between stimulation focality and the number of coils in multi-locus transcranial magnetic stimulation.
Nurmi S; Karttunen J; Souza VH; Ilmoniemi RJ; Nieminen JO
J Neural Eng; 2021 Nov; 18(6):. PubMed ID: 34673563
[No Abstract] [Full Text] [Related]
8. Magnetically Induced Temporal Interference for Focal and Deep-Brain Stimulation.
Xin Z; Kuwahata A; Liu S; Sekino M
Front Hum Neurosci; 2021; 15():693207. PubMed ID: 34646125
[TBL] [Abstract][Full Text] [Related]
9. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays.
Wei X; Li Y; Lu M; Wang J; Yi G
Int J Environ Res Public Health; 2017 Nov; 14(11):. PubMed ID: 29135963
[TBL] [Abstract][Full Text] [Related]
10. Physiological observations validate finite element models for estimating subject-specific electric field distributions induced by transcranial magnetic stimulation of the human motor cortex.
Opitz A; Legon W; Rowlands A; Bickel WK; Paulus W; Tyler WJ
Neuroimage; 2013 Nov; 81():253-264. PubMed ID: 23644000
[TBL] [Abstract][Full Text] [Related]
11. Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation.
Lu M; Ueno S
PLoS One; 2017; 12(6):e0178422. PubMed ID: 28586349
[TBL] [Abstract][Full Text] [Related]
12. Systematic numerical assessment of occupational exposure to electromagnetic fields of transcranial magnetic stimulation.
D'Agostino S; Colella M; Liberti M; Falsaperla R; Apollonio F
Med Phys; 2022 May; 49(5):3416-3431. PubMed ID: 35196394
[TBL] [Abstract][Full Text] [Related]
13. Effects of coil orientation on the electric field induced by TMS over the hand motor area.
Laakso I; Hirata A; Ugawa Y
Phys Med Biol; 2014 Jan; 59(1):203-18. PubMed ID: 24334481
[TBL] [Abstract][Full Text] [Related]
14. A multichannel magnetic stimulation system using submillimeter-sized coils: system development and experimental application to rodent brain in vivo.
Minusa S; Muramatsu S; Osanai H; Tateno T
J Neural Eng; 2019 Oct; 16(6):066014. PubMed ID: 31642445
[TBL] [Abstract][Full Text] [Related]
15. A 3-axis coil design for multichannel TMS arrays.
Navarro de Lara LI; Daneshzand M; Mascarenas A; Paulson D; Pratt K; Okada Y; Raij T; Makarov SN; Nummenmaa A
Neuroimage; 2021 Jan; 224():117355. PubMed ID: 32916290
[TBL] [Abstract][Full Text] [Related]
16. Calculating the induced electromagnetic fields in real human head by deep transcranial magnetic stimulation.
Lu M; Ueno S
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():795-8. PubMed ID: 24109807
[TBL] [Abstract][Full Text] [Related]
17. Deep Transcranial Magnetic Stimulation: Improved Coil Design and Assessment of the Induced Fields Using MIDA Model.
Samoudi AM; Tanghe E; Martens L; Joseph W
Biomed Res Int; 2018; 2018():7061420. PubMed ID: 29967781
[TBL] [Abstract][Full Text] [Related]
18. Coil design considerations for deep transcranial magnetic stimulation.
Deng ZD; Lisanby SH; Peterchev AV
Clin Neurophysiol; 2014 Jun; 125(6):1202-12. PubMed ID: 24411523
[TBL] [Abstract][Full Text] [Related]
19. [Design of a half solenoid coil for optimization of magnetic focusing in trans-cranial magnetic stimulation].
Hu W; Wang X; Yang Y; Liang D; Zhao F
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Aug; 24(4):910-3. PubMed ID: 17899772
[TBL] [Abstract][Full Text] [Related]
20. Comparison of Coil Designs for Transcranial Magnetic Stimulation of a Pig Model.
Afuwape OF; Runge J; Bentil SA; Jiles DC
Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():1535-1538. PubMed ID: 34891576
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]