These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 33019037)

  • 21. Functional electrical stimulation for foot drop in people with multiple sclerosis: The relevance and importance of addressing quality of movement.
    Smith AD; Prokopiusova T; Jones R; Burge T; Rasova K
    Mult Scler; 2021 Apr; 27(5):653-660. PubMed ID: 32833562
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of biofeedback versus switch-triggered functional electrical stimulation on sciatica-related foot drop.
    Sardaru DP; Matei D; Zaharia-Kezdi D; Pendefunda L
    J Back Musculoskelet Rehabil; 2018; 31(2):239-245. PubMed ID: 28946515
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Adaptive Stimulation Profiles Modulation for Foot Drop Correction Using Functional Electrical Stimulation: A Proof of Concept Study.
    Li Y; Yang X; Zhou Y; Chen J; Du M; Yang Y
    IEEE J Biomed Health Inform; 2021 Jan; 25(1):59-68. PubMed ID: 32340970
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Restoration of ankle movements with the ActiGait implantable drop foot stimulator: a safe and reliable treatment option for permanent central leg palsy.
    Martin KD; Polanski WH; Schulz AK; Jöbges M; Hoff H; Schackert G; Pinzer T; Sobottka SB
    J Neurosurg; 2016 Jan; 124(1):70-6. PubMed ID: 26207599
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Functional electrical stimulation on improving foot drop gait in poststroke rehabilitation: a review of its technology and clinical efficacy.
    Sabut SK; Bhattacharya SD; Manjunatha M
    Crit Rev Biomed Eng; 2013; 41(2):149-60. PubMed ID: 24580568
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Near-normal gait pattern with peroneal electrical stimulation as a neuroprosthesis in the chronic phase of stroke: a case report.
    van Swigchem R; Weerdesteyn V; van Duijnhoven HJ; den Boer J; Beems T; Geurts AC
    Arch Phys Med Rehabil; 2011 Feb; 92(2):320-4. PubMed ID: 21272732
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Long-Term Follow-up to a Randomized Controlled Trial Comparing Peroneal Nerve Functional Electrical Stimulation to an Ankle Foot Orthosis for Patients With Chronic Stroke.
    Bethoux F; Rogers HL; Nolan KJ; Abrams GM; Annaswamy T; Brandstater M; Browne B; Burnfield JM; Feng W; Freed MJ; Geis C; Greenberg J; Gudesblatt M; Ikramuddin F; Jayaraman A; Kautz SA; Lutsep HL; Madhavan S; Meilahn J; Pease WS; Rao N; Seetharama S; Sethi P; Turk MA; Wallis RA; Kufta C
    Neurorehabil Neural Repair; 2015; 29(10):911-22. PubMed ID: 25653225
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A decision support system for electrode shaping in multi-pad FES foot drop correction.
    Malešević J; Dedijer Dujović S; Savić AM; Konstantinović L; Vidaković A; Bijelić G; Malešević N; Keller T
    J Neuroeng Rehabil; 2017 Jul; 14(1):66. PubMed ID: 28673311
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A basic study on quantitative evaluation of 3-dimensional foot contact with an inertial sensor for FES foot drop correction.
    Shiotani M; Watanabe T
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():6684-7. PubMed ID: 26737826
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a self-contained accelerometry based system for control of functional electrical stimulation in hemiplegia.
    Foglyano KM; Schnellenberger JR; Kobetic R
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():5448-51. PubMed ID: 22255570
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Brain plasticity after implanted peroneal nerve electrical stimulation to improve gait in chronic stroke patients: Two case reports.
    Thibaut A; Moissenet F; Di Perri C; Schreiber C; Remacle A; Kolanowski E; Chantraine F; Bernard C; Hustinx R; Tshibanda JF; Filipetti P; Laureys S; Gosseries O
    NeuroRehabilitation; 2017; 40(2):251-258. PubMed ID: 28222547
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Gait event detection for use in FES rehabilitation by radial and tangential foot accelerations.
    Rueterbories J; Spaich EG; Andersen OK
    Med Eng Phys; 2014 Apr; 36(4):502-8. PubMed ID: 24182424
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An implantable two channel drop foot stimulator: initial clinical results.
    Kenney L; Bultstra G; Buschman R; Taylor P; Mann G; Hermens H; Holsheimer J; Nene A; Tenniglo M; van der Aa H; Hobby J
    Artif Organs; 2002 Mar; 26(3):267-70. PubMed ID: 11940030
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Natural versus artificial sensors applied in peroneal nerve stimulation.
    Upshaw BJ; Sinkjaer T
    Artif Organs; 1997 Mar; 21(3):227-31. PubMed ID: 9148712
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection.
    Kotiadis D; Hermens HJ; Veltink PH
    Med Eng Phys; 2010 May; 32(4):287-97. PubMed ID: 20153237
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implantable drop-foot stimulator.
    Veltink PH; Slycke P; Hemssems J; Buschman R; Bultstra G; Hermens H
    Med Eng Phys; 2003 Jan; 25(1):21-8. PubMed ID: 12485783
    [TBL] [Abstract][Full Text] [Related]  

  • 37. ActiGait implantable drop foot stimulator in multiple sclerosis: a new indication.
    Martin KD; Polanski WH; Schulz AK; Jöbges M; Ziemssen T; Schackert G; Pinzer T; Sobottka SB
    J Neurosurg; 2017 May; 126(5):1685-1690. PubMed ID: 27367245
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Towards physiological ankle movements with the ActiGait implantable drop foot stimulator in chronic stroke.
    Ernst J; Grundey J; Hewitt M; von Lewinski F; Kaus J; Schmalz T; Rohde V; Liebetanz D
    Restor Neurol Neurosci; 2013; 31(5):557-69. PubMed ID: 23756541
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Functional Electrical Stimulation for Foot Drop in Post-Stroke People: Quantitative Effects on Step-to-Step Symmetry of Gait Using a Wearable Inertial Sensor.
    Schifino G; Cimolin V; Pau M; da Cunha MJ; Leban B; Porta M; Galli M; Souza Pagnussat A
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33573046
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of walking speed changes on tibialis anterior EMG during healthy gait for FES envelope design in drop foot correction.
    Byrne CA; O'Keeffe DT; Donnelly AE; Lyons GM
    J Electromyogr Kinesiol; 2007 Oct; 17(5):605-16. PubMed ID: 16990012
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.