BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 33030960)

  • 1. Electrical Impedance Tomography to Detect Airway Closure Heterogeneity in Asymmetrical Acute Respiratory Distress Syndrome.
    Rozé H; Boisselier C; Bonnardel E; Perrier V; Repusseau B; Brochard L; Ouattara A
    Am J Respir Crit Care Med; 2021 Feb; 203(4):511-515. PubMed ID: 33030960
    [No Abstract]   [Full Text] [Related]  

  • 2. Electrical impedance tomography as a tool for monitoring mechanical ventilation. An introduction to the technique.
    Maciejewski D; Putowski Z; Czok M; Krzych ŁJ
    Adv Med Sci; 2021 Sep; 66(2):388-395. PubMed ID: 34371248
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrical impedance tomography: a future item on the "Christmas Wish List" of the intensivist?
    Schibler A; Calzia E
    Intensive Care Med; 2008 Mar; 34(3):400-1; author reply 583. PubMed ID: 18214441
    [No Abstract]   [Full Text] [Related]  

  • 4. The use of electrical impedance tomography for individualized ventilation strategy in COVID-19: a case report.
    Zhao Z; Zhang JS; Chen YT; Chang HT; Hsu YL; Frerichs I; Adler A
    BMC Pulm Med; 2021 Jan; 21(1):38. PubMed ID: 33482796
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of regional lung mechanics with electrical impedance tomography can determine the requirement for ECMO in patients with severe ARDS.
    Camporota L; Smith J; Barrett N; Beale R
    Intensive Care Med; 2012 Dec; 38(12):2086-7. PubMed ID: 22990870
    [No Abstract]   [Full Text] [Related]  

  • 6. Assessment of regional ventilation in acute respiratory distress syndrome by electrical impedance tomography.
    Stankiewicz-Rudnicki M; Gaszyński T; Gaszyński W
    Anaesthesiol Intensive Ther; 2015; 47(1):77-81. PubMed ID: 25751294
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring bronchoalveolar lavage with electrical impedance tomography: first experience in a patient with COVID-19.
    Fu Y; Zou R; Wang S; Wen J; Rong L; Tang M; Yu B; Cen F; Zhao Z; Frerichs I; Adler A; Liu Y; Liu L
    Physiol Meas; 2020 Sep; 41(8):085008. PubMed ID: 32736369
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Positive end-expiratory pressure titration in COVID-19 acute respiratory failure: electrical impedance tomography vs. PEEP/FiO
    Sella N; Zarantonello F; Andreatta G; Gagliardi V; Boscolo A; Navalesi P
    Crit Care; 2020 Sep; 24(1):540. PubMed ID: 32873337
    [No Abstract]   [Full Text] [Related]  

  • 9. Heterogeneity of regional inflection points from pressure-volume curves assessed by electrical impedance tomography.
    Scaramuzzo G; Spadaro S; Waldmann AD; Böhm SH; Ragazzi R; Marangoni E; Alvisi V; Spinelli E; Mauri T; Volta CA
    Crit Care; 2019 Apr; 23(1):119. PubMed ID: 30992054
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrical impedance tomography, useful bedside monitoring for severe acute respiratory distress syndrome?
    Kopp R; Breuer T
    Minerva Anestesiol; 2020 Oct; 86(10):1011-1012. PubMed ID: 32549549
    [No Abstract]   [Full Text] [Related]  

  • 11. Electrical Impedance Tomography to Titrate PEEP at Bedside in ARDS.
    Barbas ; Amato
    Respir Care; 2022 Aug; 67(8):1061-1063. PubMed ID: 35882444
    [No Abstract]   [Full Text] [Related]  

  • 12. Physiological Effects of the Open Lung Approach in Patients with Early, Mild, Diffuse Acute Respiratory Distress Syndrome: An Electrical Impedance Tomography Study.
    Cinnella G; Grasso S; Raimondo P; D'Antini D; Mirabella L; Rauseo M; Dambrosio M
    Anesthesiology; 2015 Nov; 123(5):1113-21. PubMed ID: 26397017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-fidelity computational simulation to refine strategies for lung-protective ventilation in paediatric acute respiratory distress syndrome.
    Saffaran S; Das A; Hardman JG; Yehya N; Bates DG
    Intensive Care Med; 2019 Jul; 45(7):1055-1057. PubMed ID: 30762080
    [No Abstract]   [Full Text] [Related]  

  • 14. Electrical impedance tomography-guided prone positioning in a patient with acute cor pulmonale associated with severe acute respiratory distress syndrome.
    Kotani T; Tanabe H; Yusa H; Saito S; Yamazaki K; Ozaki M
    J Anesth; 2016 Feb; 30(1):161-5. PubMed ID: 26446805
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Update in Critical Care and Acute Respiratory Distress Syndrome 2018.
    Douglas IS; Bednash JS; Fein DG; Mallampalli RK; Mansoori JN; Gershengorn HB
    Am J Respir Crit Care Med; 2019 Jun; 199(11):1335-1343. PubMed ID: 30958975
    [No Abstract]   [Full Text] [Related]  

  • 16. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.
    Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A
    Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review.
    Rosa RG; Rutzen W; Madeira L; Ascoli AM; Dexheimer Neto FL; Maccari JG; Oliveira RP; Teixeira C
    Rev Bras Ter Intensiva; 2015; 27(4):406-11. PubMed ID: 26761481
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Year in review in Intensive Care Medicine, 2007. II. Haemodynamics, pneumonia, infections and sepsis, invasive and non-invasive mechanical ventilation, acute respiratory distress syndrome.
    Antonelli M; Azoulay E; Bonten M; Chastre J; Citerio G; Conti G; De Backer D; Lemaire F; Gerlach H; Groeneveld J; Hedenstierna G; Macrae D; Mancebo J; Maggiore SM; Mebazaa A; Metnitz P; Pugin J; Wernerman J; Zhang H
    Intensive Care Med; 2008 Mar; 34(3):405-22. PubMed ID: 18236026
    [No Abstract]   [Full Text] [Related]  

  • 19. [Acute respiratory distress syndrome after gadolinium injection].
    Marinos R; Husemann B
    Med Klin Intensivmed Notfmed; 2020 Jun; 115(5):414-416. PubMed ID: 32123977
    [No Abstract]   [Full Text] [Related]  

  • 20. Electrical Impedance Tomography-based Ventilation Patterns for Evaluating Proper Ventilator Settings and to Classify Lung Morphofunction.
    Morais CCA; Berra L; Kassis EB; Cornejo RA; Campos SL; Brandão DC; de Andrade AD; Amato MBP; Costa ELV
    Am J Respir Crit Care Med; 2024 Jun; 209(12):1516-1518. PubMed ID: 38669687
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 10.