1. Accuracy of dwell position detection with a combined electromagnetic tracking brachytherapy system for treatment verification in pelvic brachytherapy.
van Heerden L; Schiphof-Godart J; Christianen M; Mens JW; Franckena M; Maenhout M; Hoogeman M; Kolkman-Deurloo IK
Radiother Oncol; 2021 Jan; 154():249-254. PubMed ID: 33038356
[TBL] [Abstract][Full Text] [Related]
2. Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy.
Kellermeier M; Herbolzheimer J; Kreppner S; Lotter M; Strnad V; Bert C
J Appl Clin Med Phys; 2017 Jan; 18(1):211-222. PubMed ID: 28291934
[TBL] [Abstract][Full Text] [Related]
3. A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization.
Damato AL; Viswanathan AN; Don SM; Hansen JL; Cormack RA
Med Phys; 2014 Oct; 41(10):101702. PubMed ID: 25281941
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of an electromagnetic tracking enabled afterloader based on the automated registration with CT phantom images.
Gomez-Sarmiento IN; Tho D; Dürrbeck C; de Jager W; Laurendeau D; Beaulieu L
Med Phys; 2024 Feb; 51(2):799-808. PubMed ID: 38127342
[TBL] [Abstract][Full Text] [Related]
5. Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance.
Guiral P; Ribouton J; Jalade P; Wang R; Galvan JM; Lu GN; Pittet P; Rivoire A; Gindraux L
Med Phys; 2016 Sep; 43(9):5240. PubMed ID: 27587055
[TBL] [Abstract][Full Text] [Related]
6. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.
Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606
[TBL] [Abstract][Full Text] [Related]
7. Commissioning of an intra-operative US guided prostate HDR system integrating an EM tracking technology.
Lavallée MC; Cantin A; Monéger F; Lefebvre M; Foster W; Vigneault E; Beaulieu L
Brachytherapy; 2021; 20(6):1296-1304. PubMed ID: 34272132
[TBL] [Abstract][Full Text] [Related]
8. Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate.
Bharat S; Kung C; Dehghan E; Ravi A; Venugopal N; Bonillas A; Stanton D; Kruecker J
Brachytherapy; 2014; 13(6):640-50. PubMed ID: 24929641
[TBL] [Abstract][Full Text] [Related]
9. A comprehensive quality assurance protocol for electromagnetic tracking in brachytherapy.
Dürrbeck C; Gomez-Sarmiento IN; Androulakis I; Sauer BC; Kolkman-Deurloo IK; Bert C; Beaulieu L
Med Phys; 2024 May; 51(5):3184-3194. PubMed ID: 38456608
[TBL] [Abstract][Full Text] [Related]
10. An integrated system for clinical treatment verification of HDR prostate brachytherapy combining source tracking with pretreatment imaging.
Smith RL; Hanlon M; Panettieri V; Millar JL; Matheson B; Haworth A; Franich RD
Brachytherapy; 2018; 17(1):111-121. PubMed ID: 28958735
[TBL] [Abstract][Full Text] [Related]
11. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: a preliminary performance study.
Zhou J; Sebastian E; Mangona V; Yan D
Med Phys; 2013 Feb; 40(2):021716. PubMed ID: 23387739
[TBL] [Abstract][Full Text] [Related]
12. Localization of reference points in electromagnetic tracking data and their application for treatment error detection in interstitial breast brachytherapy.
Dürrbeck C; Schuster S; Sauer BC; Abu-Hossin N; Strnad V; Fietkau R; Bert C
Med Phys; 2023 Sep; 50(9):5772-5783. PubMed ID: 37458615
[TBL] [Abstract][Full Text] [Related]
13. Assessment of the implant geometry in fractionated interstitial HDR breast brachytherapy using an electromagnetic tracking system.
Kellermeier M; Fietkau R; Strnad V; Bert C
Brachytherapy; 2018; 17(1):94-102. PubMed ID: 29146103
[TBL] [Abstract][Full Text] [Related]
14. Establishing a fingerprinting method for fast catheter identification in HDR brachytherapy in vivo dosimetry.
Tho D; Bélanger C; Jørgensen EB; Tanguay J; Rosales HML; Beddar S; Johansen JG; Kertzscher G; Lavallée MC; Beaulieu L
Brachytherapy; 2024; 23(2):165-172. PubMed ID: 38281894
[TBL] [Abstract][Full Text] [Related]
15. A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking.
Smith RL; Haworth A; Panettieri V; Millar JL; Franich RD
Med Phys; 2016 May; 43(5):2435. PubMed ID: 27147354
[TBL] [Abstract][Full Text] [Related]
16. Error detection using an electromagnetic tracking system in multi-catheter breast interstitial brachytherapy.
Masitho S; Kallis K; Strnad V; Fietkau R; Bert C
Phys Med Biol; 2019 Oct; 64(20):205018. PubMed ID: 31505481
[TBL] [Abstract][Full Text] [Related]
17. Introduction of a hybrid treatment delivery system used for quality assurance in multi-catheter interstitial brachytherapy.
Kallis K; Kreppner S; Lotter M; Fietkau R; Strnad V; Bert C
Phys Med Biol; 2018 May; 63(9):095008. PubMed ID: 29616659
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
Wang W; Viswanathan AN; Damato AL; Chen Y; Tse Z; Pan L; Tokuda J; Seethamraju RT; Dumoulin CL; Schmidt EJ; Cormack RA
Med Phys; 2015 Dec; 42(12):7114-21. PubMed ID: 26632065
[TBL] [Abstract][Full Text] [Related]
19. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance.
Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfelda AB
Med Phys; 2015 Feb; 42(2):663-73. PubMed ID: 25771556
[TBL] [Abstract][Full Text] [Related]
20. High-dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator.
Otani Y; Sumida I; Nose T; Shimamoto S; Okubo H; Ogawa K
J Appl Clin Med Phys; 2018 Sep; 19(5):428-434. PubMed ID: 29959815
[TBL] [Abstract][Full Text] [Related]