154 related articles for article (PubMed ID: 33038356)
41. Six-probe scintillator dosimeter for treatment verification in HDR-brachytherapy.
Gonod M; Suarez MA; Avila CC; Karakhanyan V; Eustache C; Laskri S; Crouzilles J; Vinchant JF; Aubignac L; Grosjean T
Med Phys; 2023 Nov; 50(11):7192-7202. PubMed ID: 37738612
[TBL] [Abstract][Full Text] [Related]
42. Characterization of a miniaturized scintillator detector for time-resolved treatment monitoring in HDR-brachytherapy.
Gonod M; Suarez MA; Chacon Avila C; Karakhanyan V; Eustache C; Crouzilles J; Laskri S; Vinchant JF; Aubignac L; Grosjean T
Phys Med Biol; 2022 Dec; 67(24):. PubMed ID: 36240766
[No Abstract] [Full Text] [Related]
43. Electromagnetic (EM) catheter path tracking in ultrasound-guided brachytherapy of the breast.
Janssen NNY; Brastianos H; Akingbade A; Olding T; Vaughan T; Ungi T; Lasso A; Joshi C; Korzeniowski M; Falkson C; Fichtinger G
Int J Comput Assist Radiol Surg; 2020 Oct; 15(10):1645-1652. PubMed ID: 32712885
[TBL] [Abstract][Full Text] [Related]
44. Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy.
Lugez E; Sadjadi H; Joshi CP; Akl SG; Fichtinger G
Int J Comput Assist Radiol Surg; 2017 Apr; 12(4):681-689. PubMed ID: 28215003
[TBL] [Abstract][Full Text] [Related]
45. Online pretreatment verification of high-dose rate brachytherapy using an imaging panel.
Fonseca GP; Podesta M; Bellezzo M; Van den Bosch MR; Lutgens L; Vanneste BGL; Voncken R; Van Limbergen EJ; Reniers B; Verhaegen F
Phys Med Biol; 2017 Jul; 62(13):5440-5461. PubMed ID: 28609297
[TBL] [Abstract][Full Text] [Related]
46. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system.
Poulin E; Racine E; Binnekamp D; Beaulieu L
Med Phys; 2015 Mar; 42(3):1227-32. PubMed ID: 25735278
[TBL] [Abstract][Full Text] [Related]
47. Evaluation of anatomy-based dwell position and inverse optimization in high-dose-rate brachytherapy of prostate cancer: a dosimetric comparison to a conventional cylindrical dwell position, geometric optimization, and dose-point optimization.
Yoshioka Y; Nishimura T; Kamata M; Harada H; Kanazawa K; Fuji H; Murayama S
Radiother Oncol; 2005 Jun; 75(3):311-7. PubMed ID: 15890425
[TBL] [Abstract][Full Text] [Related]
48. US-guided EM tracked system for HDR brachytherapy: A first in-men randomized study for whole prostate treatment.
Lavallee MC; Cantin A; Aubin S; Lefebvre M; Marrier AS; Bouchard I; Fiset C; Villeneuve-Gauthier A; Foster W; Martin AG; Carignan D; Beaulieu L; Vigneault E
Brachytherapy; 2024; 23(1):64-72. PubMed ID: 37806788
[TBL] [Abstract][Full Text] [Related]
49. Feasibility study of navigated endoscopy for the placement of high dose rate brachytherapy applicators in the esophagus and lung.
Weersink RA; Qiu J; Martinez D; Rink A; Borg J; Di Tomasso A; Irish JC; Jaffray DA
Med Phys; 2020 Mar; 47(3):917-926. PubMed ID: 31883342
[TBL] [Abstract][Full Text] [Related]
50. Improving the dosimetric coverage of interstitial high-dose-rate breast implants.
Kestin LL; Jaffray DA; Edmundson GK; Martinez AA; Wong JW; Kini VR; Chen PY; Vicini FA
Int J Radiat Oncol Biol Phys; 2000 Jan; 46(1):35-43. PubMed ID: 10656370
[TBL] [Abstract][Full Text] [Related]
51. Derivation of in vivo source tracking error thresholds for TRUS-based HDR prostate brachytherapy through simulation of source positioning errors.
Poder J; Carrara M; Howie A; Cutajar D; Bucci J; Rosenfeld A
Brachytherapy; 2019; 18(5):711-719. PubMed ID: 31175015
[TBL] [Abstract][Full Text] [Related]
52. 3D catheter reconstruction in HDR prostate brachytherapy for pre-treatment verification using a flat panel detector.
Smith RL; Haworth A; Panettieri V; Millar JL; Franich RD
Phys Med; 2017 Jul; 39():121-131. PubMed ID: 28625472
[TBL] [Abstract][Full Text] [Related]
53. Accuracy of applicator tip reconstruction in MRI-guided interstitial 192Ir-high-dose-rate brachytherapy of liver tumors.
Wybranski C; Eberhardt B; Fischbach K; Fischbach F; Walke M; Hass P; Röhl FW; Kosiek O; Kaiser M; Pech M; Lüdemann L; Ricke J
Radiother Oncol; 2015 Apr; 115(1):72-7. PubMed ID: 25779722
[TBL] [Abstract][Full Text] [Related]
54. Independent verification of brachytherapy treatment plan by using deep learning inference modeling.
Fan J; Xing L; Yang Y
Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 34132651
[TBL] [Abstract][Full Text] [Related]
55. Technical Note: A comparison of point set registration methods for electromagnetic tracking.
Götz TI; Wankerl H; Tomé AM; Meyer-Baese A; Bert C; Hensel B; Lang EW
Med Phys; 2019 May; 46(5):2025-2030. PubMed ID: 30748029
[TBL] [Abstract][Full Text] [Related]
56. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions.
Candela-Juan C; Niatsetski Y; van der Laarse R; Granero D; Ballester F; Perez-Calatayud J; Vijande J
Med Phys; 2016 Apr; 43(4):1639. PubMed ID: 27036563
[TBL] [Abstract][Full Text] [Related]
57. EM-enhanced US-based seed detection for prostate brachytherapy.
Dehghan E; Bharat S; Kung C; Bonillas A; Beaulieu L; Pouliot J; Kruecker J
Med Phys; 2018 Jun; 45(6):2357-2368. PubMed ID: 29604086
[TBL] [Abstract][Full Text] [Related]
58. Development of an HDR-BT QA tool for source position verification.
Kumazaki Y; Hirai R; Igari M; Kobayashi N; Okazaki S; Abe T; Tamaki T; Noda SE; Kato S
J Appl Clin Med Phys; 2020 Dec; 21(12):84-89. PubMed ID: 33136313
[TBL] [Abstract][Full Text] [Related]
59. Reconstruction accuracy of a dedicated localiser for filmless planning in intra-operative brachytherapy.
Kolkman-Deurloo IK; Visser AG; Idzes MH; Levendag PC
Radiother Oncol; 1997 Jul; 44(1):73-81. PubMed ID: 9288861
[TBL] [Abstract][Full Text] [Related]
60. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.
Poulin E; Fekete CA; Létourneau M; Fenster A; Pouliot J; Beaulieu L
Med Phys; 2013 Nov; 40(11):111724. PubMed ID: 24320432
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]