These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 33040996)

  • 1. Practical Aspects of MR Imaging Safety Test Methods for MR Conditional Active Implantable Medical Devices.
    Al-Dayeh L; Rahman M; Venook R
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):559-571. PubMed ID: 33040996
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MR Safety: Active Implanted Electronic Devices.
    Watson RE; Edmonson HA
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):549-558. PubMed ID: 33040995
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Practical Guide to MR Imaging Safety: What Radiologists Need to Know.
    Tsai LL; Grant AK; Mortele KJ; Kung JW; Smith MP
    Radiographics; 2015 Oct; 35(6):1722-37. PubMed ID: 26466181
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Standardized Approaches to MR Safety Assessment of Patients with Implanted Devices.
    Kanal E
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):537-548. PubMed ID: 33040994
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MR conditional safety assessment of implanted medical devices: advantages of computational human phantoms.
    Brown JE; Rui Qiang ; Stadnik PJ; Stotts LJ; Von Arx JA
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():6465-6468. PubMed ID: 28269727
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a Searchable System to Confirm MR Imaging Safety Information for Implantable Medical Devices.
    Fujiwara Y; Fujioka H; Sekiguchi M; Tanaka H; Watanabe T
    Magn Reson Med Sci; 2019 Oct; 18(4):286-292. PubMed ID: 30787251
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Virtual Humans for Implantable Device Safety Assessment in MRI: Mitigating Magnetic Resonance Imaging Hazards for Implanted Medical Devices.
    Brown JE; Qiang R; Stadnik PJ; Stotts LJ; Von Arx JA
    IEEE Pulse; 2017; 8(4):50-53. PubMed ID: 28715316
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MRI information for commonly used otologic implants: review and update.
    Azadarmaki R; Tubbs R; Chen DA; Shellock FG
    Otolaryngol Head Neck Surg; 2014 Apr; 150(4):512-9. PubMed ID: 24398365
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetic Resonance Safety in the 7T Environment.
    Fagan AJ; Amrami KK; Welker KM; Frick MA; Felmlee JP; Watson RE
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):573-582. PubMed ID: 33040997
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Elements of Effective Patient Screening to Improve Safety in MRI.
    Kimbrell V
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):489-496. PubMed ID: 33040990
    [TBL] [Abstract][Full Text] [Related]  

  • 11. MR Imaging Safety Events: Analysis and Improvement.
    Watson RE; Tesfaldet M; Warren J; Hoff MN
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):593-600. PubMed ID: 33040999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR safety assessment of active implantable medical devices.
    Aissani S; Laistler E; Felblinger J
    Radiologe; 2019 Dec; 59(Suppl 1):40-45. PubMed ID: 31321466
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MRI in Adult Patients with Active and Inactive Implanted MR-conditional, MR-nonconditional, and Other Devices.
    Harwood M; Fahrenholtz SJ; Wellnitz CV; Kawashima A; Panda A
    Radiographics; 2024 Mar; 44(3):e230102. PubMed ID: 38421911
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison Study between the Second and First Editions of ISO/ TS 10974-Assessment of the Safety of Magnetic Resonance Imaging for Patients with an Active Implantable Medical Device].
    Li Y; Wang J; Zhang W; Hu S
    Zhongguo Yi Liao Qi Xie Za Zhi; 2021 Feb; 45(1):90-95. PubMed ID: 33522185
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Standardized MR terminology and reporting of implants and devices as recommended by the American College of Radiology Subcommittee on MR Safety.
    Kanal E; Froelich J; Barkovich AJ; Borgstede J; Bradley W; Gimbel JR; Gosbee J; Greenberg T; Jackson E; Larson P; Lester J; Sebek E; Shellock FG; Weinreb J; Wilkoff BL; Hernandez D;
    Radiology; 2015 Mar; 274(3):866-70. PubMed ID: 25329683
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiovascular implantable electronic devices: a review of the dangers and difficulties in MR scanning and attempts to improve safety.
    Poh PG; Liew C; Yeo C; Chong LR; Tan A; Poh A
    Insights Imaging; 2017 Aug; 8(4):405-418. PubMed ID: 28624970
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New Insights into MR Safety for Implantable Medical Devices.
    Kuroda K; Yatsushiro S
    Magn Reson Med Sci; 2022 Mar; 21(1):110-131. PubMed ID: 35228487
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Test methods to determine magnetic resonance (MR) safety and MR image compatibility of implants/devices].
    Schaefers G
    Radiologe; 2019 Oct; 59(10):875-884. PubMed ID: 31591698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implantable Electronic Cardiac Devices and Compatibility With Magnetic Resonance Imaging.
    Miller JD; Nazarian S; Halperin HR
    J Am Coll Cardiol; 2016 Oct; 68(14):1590-8. PubMed ID: 27687201
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Response to Standardized MR Terminology and Reporting of Implants and Devices as Recommended by the American College of Radiology Subcommittee on MR Safety.
    Woods TO; Delfino JG; Shein MJ
    Radiology; 2016 Jun; 279(3):906-9. PubMed ID: 26599665
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.