These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 33063194)

  • 1. A new method using a vessel-sealing system provides coagulation effects to various types of bleeding with less thermal damage.
    Oyama S; Nonaka T; Matsumoto K; Taniguchi D; Hashimoto Y; Obata T; Hisanaga M; Moriyama M; Matsuo N; Wada H; Hamada K; Wakata K; Tominaga T; Hidaka S; Sawai T; Nagayasu T
    Surg Endosc; 2021 Mar; 35(3):1453-1464. PubMed ID: 33063194
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices.
    Chen J; Jensen CR; Manwaring PK; Glasgow RE
    Surg Laparosc Endosc Percutan Tech; 2017 Apr; 27(2):e12-e17. PubMed ID: 28234706
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of two different energy-based vascular sealing systems for the hemostasis of various types of arteries: a porcine model-evaluation of LigaSure ForceTriad™.
    Katsuno G; Nagakari K; Fukunaga M
    J Laparoendosc Adv Surg Tech A; 2010 Nov; 20(9):747-51. PubMed ID: 20925574
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time thermography during energized vessel sealing and dissection.
    Campbell PA; Cresswell AB; Frank TG; Cuschieri A
    Surg Endosc; 2003 Oct; 17(10):1640-5. PubMed ID: 12874690
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Infrared laser sealing of porcine vascular tissues using a 1,470 nm diode laser: Preliminary in vivo studies.
    Cilip CM; Kerr D; Latimer CA; Rosenbury SB; Giglio NC; Hutchens TC; Nau WH; Fried NM
    Lasers Surg Med; 2017 Apr; 49(4):366-371. PubMed ID: 27785787
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Greater surgical precision of a flexible carbon dioxide laser fiber compared to monopolar electrosurgery in porcine myometrium.
    Bailey AP; Lancerotto L; Gridley C; Orgill DP; Nguyen H; Pescarini E; Lago G; Gargiulo AR
    J Minim Invasive Gynecol; 2014; 21(6):1103-9. PubMed ID: 24858988
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implementation of a novel efficacy score to compare sealing and cutting devices in a porcine model.
    Brecht L; Wallwiener M; Schott S; Domschke C; Dinkic C; Golatta M; Schuetz F; Fluhr H; Stenzinger A; Kirchner M; Sohn C; Rom J
    Surg Endosc; 2018 Feb; 32(2):1002-1011. PubMed ID: 28840380
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a novel electrosurgical sealing mode in an ex vivo and in vivo porcine model.
    Thiel K; Linzenbold W; Enderle MD; Nold B; Königsrainer A; Schenk M; Thiel C
    Surg Endosc; 2018 Mar; 32(3):1456-1463. PubMed ID: 28924734
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy and safety of the novel electrosurgical vessel sealing and cutting instrument BiCision®.
    Rothmund R; Kraemer B; Neis F; Brucker S; Wallwiener M; Reda A; Hausch A; Scharpf M; Szyrach MN
    Surg Endosc; 2012 Nov; 26(11):3334-43. PubMed ID: 22678171
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Randomized Trial of Monopolar Soft-mode Coagulation Versus Heater Probe Thermocoagulation for Peptic Ulcer Bleeding.
    Nunoue T; Takenaka R; Hori K; Okazaki N; Hamada K; Baba Y; Yamasaki Y; Kono Y; Seki H; Inokuchi T; Takemoto K; Taira A; Tsugeno H; Fujiki S; Kawahara Y; Okada H
    J Clin Gastroenterol; 2015 Jul; 49(6):472-6. PubMed ID: 25083773
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Repeated partial tissue bite with inadequate cooling time for an energy device may cause thermal injury.
    Shibao K; Joden F; Adachi Y; Kohi S; Kudou Y; Kikuchi Y; Matayoshi N; Sato N; Murayama R; Hirata K
    Surg Endosc; 2021 Jun; 35(6):3189-3198. PubMed ID: 33523265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Steam induced by the activation of energy devices under a wet condition may cause thermal injury.
    Hayami M; Watanabe M; Mine S; Imamura Y; Okamura A; Yuda M; Yamashita K; Shoji Y; Toihata T; Kozuki R; Ishizuka N
    Surg Endosc; 2020 May; 34(5):2295-2302. PubMed ID: 31811453
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Energy Device and Soft Coagulation System in Thoracic Surgery].
    Azuma Y; Iyoda A
    Kyobu Geka; 2018 Sep; 71(10):759-762. PubMed ID: 30310023
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical utility of a novel ultrasonic vessel sealing device in transecting and sealing large vessels during laparoscopic hysterectomy using advanced hemostasis mode.
    Nieboer TE; Steller CJ; Hinoul P; Maxson AJ; Schwiers ML; Miller CE; Coppus SF; Kent AS
    Eur J Obstet Gynecol Reprod Biol; 2016 Jun; 201():135-9. PubMed ID: 27124666
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices.
    Newcomb WL; Hope WW; Schmelzer TM; Heath JJ; Norton HJ; Lincourt AE; Heniford BT; Iannitti DA
    Surg Endosc; 2009 Jan; 23(1):90-6. PubMed ID: 18483824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of laparoscopic energy devices on charges in thermal power after application to porcine mesentery.
    Eto K; Omura N; Haruki K; Uno Y; Ohkuma M; Nakajima S; Anan T; Kosuge M; Fujita T; Yanaga K
    Surg Laparosc Endosc Percutan Tech; 2015 Feb; 25(1):e37-e41. PubMed ID: 25635674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments.
    Seehofer D; Mogl M; Boas-Knoop S; Unger J; Schirmeier A; Chopra S; Eurich D
    Surg Endosc; 2012 Sep; 26(9):2541-9. PubMed ID: 22447285
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma.
    Smith CT; Zarebczan B; Alhefdhi A; Chen H
    J Surg Res; 2011 Sep; 170(1):64-8. PubMed ID: 21529840
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of coagulation modalities in surgery.
    Lantis JC II; Durville FM; Connolly R; Schwaitzberg SD
    J Laparoendosc Adv Surg Tech A; 1998 Dec; 8(6):381-94. PubMed ID: 9916591
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomized comparison of a new flexible bipolar hemostasis forceps designed principally for NOTES versus a conventional surgical laparoscopic bipolar forceps for intra-abdominal vessel sealing in a porcine model.
    Park PO; Long GL; Bergström M; Cunningham C; Vakharia OJ; Bakos GJ; Bally KR; Rothstein RI; Swain CP
    Gastrointest Endosc; 2010 Apr; 71(4):835-41. PubMed ID: 19942215
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.