126 related articles for article (PubMed ID: 33090257)
1. Estimation of renal function using kidney dynamic contrast material-enhanced CT perfusion: accuracy and feasibility.
Jeong S; Park SB; Chang IH; Shin J; Chi BH; Park HJ; Lee ES
Abdom Radiol (NY); 2021 May; 46(5):2045-2051. PubMed ID: 33090257
[TBL] [Abstract][Full Text] [Related]
2. Assessment of Split Renal Function Using a Combination of Contrast-Enhanced CT and Serum Creatinine Values for Glomerular Filtration Rate Estimation.
Shi W; Liang X; Wu N; Zhang H; Yuan X; Tan Y
AJR Am J Roentgenol; 2020 Jul; 215(1):142-147. PubMed ID: 32255686
[No Abstract] [Full Text] [Related]
3. Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method.
You S; Ma X; Zhang C; Li Q; Shi W; Zhang J; Yuan X
Eur Radiol; 2018 Mar; 28(3):1077-1084. PubMed ID: 28971295
[TBL] [Abstract][Full Text] [Related]
4. Estimation of renal function using iodine maps in dual-energy spectral computed tomography urography: a feasibility and accuracy study.
Wang S; Tong X; Zhang J; Fan Y; Wei W; Li J; Liu Y; Hu M; Chen Q; Liu L
Abdom Radiol (NY); 2024 Mar; 49(3):997-1005. PubMed ID: 38244037
[TBL] [Abstract][Full Text] [Related]
5. A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography.
Jiang K; Ferguson CM; Abumoawad A; Saad A; Textor SC; Lerman LO
PLoS One; 2019; 14(7):e0219605. PubMed ID: 31291361
[TBL] [Abstract][Full Text] [Related]
6. [Multi-slice spiral CT scan with lower dose for preoperative evaluation: living renal donor kidney morphology and the quantification of unilateral glomerular filtration rate].
Su C; Guo Y; Wang CX; Yan CG; Zhou XH; Liu LS; Zhang L
Zhonghua Yi Xue Za Zhi; 2011 Oct; 91(38):2697-701. PubMed ID: 22321980
[TBL] [Abstract][Full Text] [Related]
7. Determination of glomerular filtration rate in anesthetized pigs by use of three-phase whole-kidney computed tomography and Patlak plot analysis.
Alexander K; Ybarra N; del Castillo JR; Morin V; Gauvin D; Bichot S; Beauchamp G; Troncy E
Am J Vet Res; 2008 Nov; 69(11):1455-62. PubMed ID: 18980427
[TBL] [Abstract][Full Text] [Related]
8. Functional imaging in computed tomography. The use of contrast-enhanced computed tomography for the study of renal function and physiology.
Dawson P; Peters AM
Invest Radiol; 1993 Nov; 28 Suppl 5():S79-84; discussion S85-6. PubMed ID: 8282509
[TBL] [Abstract][Full Text] [Related]
9. Effects of Changes in Analytic Variables and Contrast Material on Measurement of Computed Tomography Glomerular Filtration Rates in Healthy Candidates.
Kim SH
J Comput Assist Tomogr; 2020; 44(2):217-222. PubMed ID: 31996652
[TBL] [Abstract][Full Text] [Related]
10. How to estimate renal function in patients with liver disease: choosing the most suitable equation.
Ren S; Chang Y; Zhang Q; Wang X; Niu H; Chen L; Lv C; Zhang Z; Xiang X; Zhu L; Li H
Int Urol Nephrol; 2019 Apr; 51(4):677-690. PubMed ID: 30830657
[TBL] [Abstract][Full Text] [Related]
11. A Simplified Whole-Organ CT Perfusion Technique with Biphasic Acquisition: Preliminary Investigation of Accuracy and Protocol Feasibility in Kidneys.
Yuan X; Zhang J; Quan C; Tian Y; Li H; Ao G
Radiology; 2016 Apr; 279(1):254-61. PubMed ID: 26536310
[TBL] [Abstract][Full Text] [Related]
12. Feasibility of gamma camera-based GFR measurement using renal depth evaluated by lateral scan of
Sugawara S; Ishii S; Kojima Y; Ito H; Suzuki Y; Oriuchi N
Ann Nucl Med; 2020 May; 34(5):349-357. PubMed ID: 32166712
[TBL] [Abstract][Full Text] [Related]
13. Performance of CKD-EPI equation to estimate glomerular filtration rate as compared to MDRD equation in South Brazilian individuals in each stage of renal function.
Veronese FV; Gomes EC; Chanan J; Carraro MA; Camargo EG; Soares AA; Thomé FS; Silveiro SP
Clin Chem Lab Med; 2014 Dec; 52(12):1747-54. PubMed ID: 24940711
[TBL] [Abstract][Full Text] [Related]
14. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.
Matsuda Y; Kishimoto M; Kushida K; Yamada K; Shimizu M; Itoh H
Am J Vet Res; 2017 Sep; 78(9):1049-1055. PubMed ID: 28836837
[TBL] [Abstract][Full Text] [Related]
15. Measurement of Murine Single-Kidney Glomerular Filtration Rate Using Dynamic Contrast-Enhanced MRI.
Jiang K; Tang H; Mishra PK; Macura SI; Lerman LO
Magn Reson Med; 2018 Jun; 79(6):2935-2943. PubMed ID: 29034514
[TBL] [Abstract][Full Text] [Related]
16. Single-slice dynamic computed tomographic determination of glomerular filtration rate by use of Patlak plot analysis in anesthetized pigs.
Alexander K; Del Castillo JR; Ybarra N; Morin V; Gauvin D; Authier S; Vinay P; Troncy E
Am J Vet Res; 2007 Mar; 68(3):297-304. PubMed ID: 17331020
[TBL] [Abstract][Full Text] [Related]
17. Accuracy and precision of the CKD-EPI and MDRD predictive equations compared with glomerular filtration rate measured by inulin clearance in a Saudi population.
Al-Wakeel JS
Ann Saudi Med; 2016; 36(2):128-34. PubMed ID: 27018810
[TBL] [Abstract][Full Text] [Related]
18. Measuring single-kidney glomerular filtration rate on single-detector helical CT using a two-point Patlak plot technique in patients with increased interstitial space.
Hackstein N; Bauer J; Hauck EW; Ludwig M; Krämer HJ; Rau WS
AJR Am J Roentgenol; 2003 Jul; 181(1):147-56. PubMed ID: 12818847
[TBL] [Abstract][Full Text] [Related]
19. Feasibility of triphasic CT with a modified two-point Patlak plot to determine spit kidney glomerular filtration rate in clinical practice.
Zhang YD; Xue CQ; Wu CJ; Tao J; Zhou WL; Shi HB
Abdom Radiol (NY); 2017 Jan; 42(1):226-235. PubMed ID: 27503300
[TBL] [Abstract][Full Text] [Related]
20. Glomerular filtration rate measured by using triphasic helical CT with a two-point Patlak plot technique.
Hackstein N; Wiegand C; Rau WS; Langheinrich AC
Radiology; 2004 Jan; 230(1):221-6. PubMed ID: 14645882
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]