These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

292 related articles for article (PubMed ID: 33092751)

  • 1. Esophageal Endoscopy After Catheter Ablation of Atrial Fibrillation Using Ablation-Index Guided High-Power: Frankfurt AI-HP ESO-I.
    Chen S; Chun KRJ; Tohoku S; Bordignon S; Urbanek L; Willems F; Plank K; Hilbert M; Konstantinou A; Tsianakas N; Bologna F; Kreuzer C; Trolese L; Schmidt B
    JACC Clin Electrophysiol; 2020 Oct; 6(10):1253-1261. PubMed ID: 33092751
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Catheter ablation of atrial fibrillation using ablation index-guided high power (50 W) for pulmonary vein isolation with or without esophageal temperature probe (the AI-HP ESO II).
    Chen S; Schmidt B; Seeger A; Bordignon S; Tohoku S; Willems F; Urbanek L; Throm C; Konstantinou A; Plank K; Hilbert M; Zanchi S; Bianchini L; Bologna F; Tsianakas N; Kreuzer C; Chun KRJ
    Heart Rhythm; 2020 Nov; 17(11):1833-1840. PubMed ID: 32470628
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Catheter ablation of atrial fibrillation using ablation index-guided high-power technique: Frankfurt AI high-power 15-month follow-up.
    Chen S; Schmidt B; Bordignon S; Tohoku S; Urban VC; Schulte-Hahn B; Chun KRJ
    J Cardiovasc Electrophysiol; 2021 Mar; 32(3):616-624. PubMed ID: 33484215
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study.
    Chen S; Schmidt B; Bordignon S; Urbanek L; Tohoku S; Bologna F; Angelkov L; Garvanski I; Tsianakas N; Konstantinou A; Trolese L; Weise F; Perrotta L; Chun KRJ
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2724-2731. PubMed ID: 31588620
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endoscopic evaluation of the esophagus after catheter ablation of atrial fibrillation using contiguous and optimized radiofrequency applications.
    Wolf M; El Haddad M; De Wilde V; Phlips T; De Pooter J; Almorad A; Strisciuglio T; Vandekerckhove Y; Tavernier R; Crijns HJ; Knecht S; Duytschaever M
    Heart Rhythm; 2019 Jul; 16(7):1013-1020. PubMed ID: 30710736
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation.
    Okamatsu H; Koyama J; Sakai Y; Negishi K; Hayashi K; Tsurugi T; Tanaka Y; Nakao K; Sakamoto T; Okumura K
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2751-2758. PubMed ID: 31600006
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Temperature monitoring and temperature-driven irrigated radiofrequency energy titration do not prevent thermally induced esophageal lesions in pulmonary vein isolation: A randomized study controlled by esophagoscopy before and after catheter ablation.
    Grosse Meininghaus D; Blembel K; Waniek C; Kruells-Muench J; Ernst H; Kleemann T; Geller JC
    Heart Rhythm; 2021 Jun; 18(6):926-934. PubMed ID: 33561587
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical outcome of lesion size index-guided high-power radiofrequency catheter ablation for pulmonary vein isolation in patients with atrial fibrillation: 2-year follow-up.
    Cai C; Wang J; Niu HX; Chu JM; Hua W; Zhang S; Yao Y
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):546-555. PubMed ID: 36640429
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Esophageal safety in CLOSE-guided 50 W high-power-short-duration pulmonary vein isolation: The PREHEAT-PVI-registry.
    Francke A; Naumann G; Weidauer MC; Scharfe F; Schoen S; Wunderlich C; Christoph M
    J Cardiovasc Electrophysiol; 2022 Nov; 33(11):2276-2284. PubMed ID: 35979645
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characteristics of Esophageal Injury in Ablation of Atrial Fibrillation Using a High-Power Short-Duration Setting.
    Kaneshiro T; Kamioka M; Hijioka N; Yamada S; Yokokawa T; Misaka T; Hikichi T; Yoshihisa A; Takeishi Y
    Circ Arrhythm Electrophysiol; 2020 Oct; 13(10):e008602. PubMed ID: 32915644
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.
    Leite LR; Santos SN; Maia H; Henz BD; Giuseppin F; Oliverira A; Zanatta AR; Peres AK; Novakoski C; Barreto JR; Vassalo F; d'Avila A; Singh SM
    Circ Arrhythm Electrophysiol; 2011 Apr; 4(2):149-56. PubMed ID: 21325208
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Incidence of ablation-induced esophageal injury associated with high-power short duration temperature-controlled pulmonary vein isolation using a specialized open-irrigated ablation catheter: A retrospective single-center study.
    Piringer R; Deneke T; Foldyna B; Sonne K; Nentwich K; Ene E; Barth S; Lüsebrink U; Berkovitz A; Halbfass P
    J Cardiovasc Electrophysiol; 2021 Mar; 32(3):695-703. PubMed ID: 33442930
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduced esophageal heating in high-power short-duration atrial fibrillation ablation in the contact force catheter era.
    Vassallo F; Meigre LL; Serpa E; Cunha CL; Carloni H; Simoes A; Amaral D; Lovatto C
    Pacing Clin Electrophysiol; 2021 Jul; 44(7):1185-1192. PubMed ID: 34081339
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calculated parameters of luminal esophageal temperatures predict esophageal injury following conventional and high-power short-duration radiofrequency pulmonary vein isolation.
    Grosse Meininghaus D; Freund R; Kleemann T; Christoph Geller J
    J Cardiovasc Electrophysiol; 2022 Jun; 33(6):1167-1176. PubMed ID: 35445476
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Acute oesophageal safety of high-power short duration with 50 W for atrial fibrillation ablation.
    Müller J; Berkovitz A; Halbfass P; Nentwich K; Ene E; Sonne K; Simu G; Chakarov I; Barth S; Waechter C; Behnes M; Akin I; Deneke T
    Europace; 2022 Jul; 24(6):928-937. PubMed ID: 35134155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Esophageal temperature dynamics during high-power short-duration posterior wall ablation.
    Barbhaiya CR; Kogan EV; Jankelson L; Knotts RJ; Spinelli M; Bernstein S; Park D; Aizer A; Chinitz LA; Holmes D
    Heart Rhythm; 2020 May; 17(5 Pt A):721-727. PubMed ID: 31978595
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Higher power short duration vs. lower power longer duration posterior wall ablation for atrial fibrillation and oesophageal injury outcomes: a prospective multi-centre randomized controlled study (Hi-Lo HEAT trial).
    Chieng D; Segan L; Sugumar H; Al-Kaisey A; Hawson J; Moore BM; Nam MCY; Voskoboinik A; Prabhu S; Ling LH; Ng JF; Brown G; Lee G; Morton J; Debinski H; Kalman JM; Kistler PM
    Europace; 2023 Feb; 25(2):417-424. PubMed ID: 36305561
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation.
    Hussein A; Das M; Chaturvedi V; Asfour IK; Daryanani N; Morgan M; Ronayne C; Shaw M; Snowdon R; Gupta D
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):1037-1047. PubMed ID: 28639728
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Procedural efficacy and safety of standardized, ablation index guided fixed 50 W high-power short-duration pulmonary vein isolation and substrate modification using the CLOSE protocol.
    Francke A; Taha NS; Scharfe F; Schoen S; Wunderlich C; Christoph M
    J Cardiovasc Electrophysiol; 2021 Sep; 32(9):2408-2417. PubMed ID: 34252990
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ablation of atrial fibrillation and esophageal injury: Role of bipolar and unipolar energy using a novel multipolar irrigated ablation catheter.
    Di Monaco A; Quadrini F; Katsouras G; Caccavo V; Troisi F; Quatraro F; Cecere G; Langialonga T; Grimaldi M
    Heart Rhythm; 2015 Jun; 12(6):1120-7. PubMed ID: 25766775
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.