These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 33119540)

  • 41. Measurement of serum total vitamin D (25-OH) using automated immunoassay in comparison [corrected] with liquid chromatography tandem-mass spectrometry.
    Shin SY; Kwon MJ; Song J; Park H; Woo HY
    J Clin Lab Anal; 2013 Jul; 27(4):284-9. PubMed ID: 23852785
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Performance characteristics of the VIDAS® 25-OH Vitamin D Total assay - comparison with four immunoassays and two liquid chromatography-tandem mass spectrometry methods in a multicentric study.
    Moreau E; Bächer S; Mery S; Le Goff C; Piga N; Vogeser M; Hausmann M; Cavalier E
    Clin Chem Lab Med; 2016 Jan; 54(1):45-53. PubMed ID: 26124054
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Two-site evaluation of the Roche Elecsys Vitamin D total III assay.
    Favresse J; Schiettecatte J; Wolff F; Cotton F; Elsen M; Eucher C; Rosseels C; Anckaert E
    Clin Chem Lab Med; 2022 Sep; 60(10):1598-1606. PubMed ID: 35849629
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3.
    Netzel BC; Cradic KW; Bro ET; Girtman AB; Cyr RC; Singh RJ; Grebe SK
    Clin Chem; 2011 Mar; 57(3):431-40. PubMed ID: 21245371
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Standardization of misleading immunoassay based 25-hydroxyvitamin D levels with liquid chromatography tandem-mass spectrometry in a large cohort study.
    Schöttker B; Jansen EH; Haug U; Schomburg L; Köhrle J; Brenner H
    PLoS One; 2012; 7(11):e48774. PubMed ID: 23133659
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D₃ and 25-hydroxyvitamin D₂ using isotope-dilution liquid chromatography-tandem mass spectrometry.
    Mineva EM; Schleicher RL; Chaudhary-Webb M; Maw KL; Botelho JC; Vesper HW; Pfeiffer CM
    Anal Bioanal Chem; 2015 Jul; 407(19):5615-24. PubMed ID: 25967149
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference.
    Roth HJ; Schmidt-Gayk H; Weber H; Niederau C
    Ann Clin Biochem; 2008 Mar; 45(Pt 2):153-9. PubMed ID: 18325178
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Biotin supplementation causes erroneous elevations of results in some commercial serum 25-hydroxyvitamin d (25OHD) assays.
    Carter GD; Berry J; Cavalier E; Durazo-Arvizu R; Gunter E; Jones G; Jones J; Phinney K; Sempos CT; Twomey PJ; Williams EL
    J Steroid Biochem Mol Biol; 2020 Jun; 200():105639. PubMed ID: 32084550
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Assessment of Abbott Architect 25-OH vitamin D assay in different levels of vitamin D.
    Avci E; Demir S; Aslan D; Nar R; Şenol H
    J Med Biochem; 2020 Jan; 39(1):100-107. PubMed ID: 32549783
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE).
    Thibeault D; Caron N; Djiana R; Kremer R; Blank D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():120-7. PubMed ID: 22265352
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Total serum vitamin B12 (cobalamin) LC-MS/MS assay as an arbiter of clinically discordant immunoassay results.
    Zhang R; Ma X; Zou Y; Qiu L; Wang D; Tang Y; Cao Y; Yu S; Cheng X
    Clin Chem Lab Med; 2023 Jan; 61(1):86-92. PubMed ID: 36103653
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Multiplex LC-MS/MS for simultaneous determination of 25-hydroxyvitamin D, 24,25-dihydroxyvitamin D
    Ko DH; Jun SH; Nam Y; Song SH; Han M; Yun YM; Lee K; Song J
    J Steroid Biochem Mol Biol; 2021 Feb; 206():105796. PubMed ID: 33259939
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Performance Evaluation and Measurement Uncertainty Determination of the New Version of the Abbott ARCHITECT 25-OH Vitamin D 5P02 Assay.
    Lim YK; Park AJ; Kweon OJ; Choi JH
    Am J Clin Pathol; 2019 Jan; 151(2):209-216. PubMed ID: 30307462
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Analytical Evaluation of Vitamin D Measurements in Routine Laboratories.
    Yis OM; Bugdayci G; Sönmez ÇA; Yıldız RN
    Clin Lab; 2019 Mar; 65(3):. PubMed ID: 30868850
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3.
    Maunsell Z; Wright DJ; Rainbow SJ
    Clin Chem; 2005 Sep; 51(9):1683-90. PubMed ID: 16020493
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Analytical and clinical validation of the new Abbot Architect 25(OH)D assay: fit for purpose?
    Cavalier E; Lukas P; Bekaert AC; Carlisi A; Le Goff C; Delanaye P; Souberbielle JC
    Clin Chem Lab Med; 2017 Mar; 55(3):378-384. PubMed ID: 27522099
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Four automated 25-OH total vitamin D immunoassays and commercial liquid chromatography tandem-mass spectrometry in Finnish population.
    Koivula MK; Matinlassi N; Laitinen P; Risteli J
    Clin Lab; 2013; 59(3-4):397-405. PubMed ID: 23724631
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry.
    Stepman HC; Vanderroost A; Van Uytfanghe K; Thienpont LM
    Clin Chem; 2011 Mar; 57(3):441-8. PubMed ID: 21248072
    [TBL] [Abstract][Full Text] [Related]  

  • 59. 25-Hydroxyvitamin D assays: Potential interference from other circulating vitamin D metabolites.
    Carter GD; Jones JC; Shannon J; Williams EL; Jones G; Kaufmann M; Sempos C
    J Steroid Biochem Mol Biol; 2016 Nov; 164():134-138. PubMed ID: 26718874
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.
    Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F
    Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.