BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 33119953)

  • 1. Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases.
    Nakano H; Tanabe S; Utsunomiya S; Yamada T; Sasamoto R; Nakano T; Saito H; Takizawa T; Sakai H; Ohta A; Abe E; Kaidu M; Aoyama H
    J Appl Clin Med Phys; 2020 Dec; 21(12):155-165. PubMed ID: 33119953
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery.
    Nakano H; Tanabe S; Sasamoto R; Takizawa T; Utsunomiya S; Sakai M; Nakano T; Ohta A; Kaidu M; Ishikawa H
    J Appl Clin Med Phys; 2021 Jul; 22(7):266-275. PubMed ID: 34151498
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis.
    Nakano H; Tanabe S; Yamada T; Utsunomiya S; Takizawa T; Sakai M; Sasamoto R; Sakai H; Nakano T; Saito H; Ohta A; Kaidu M; Ishikawa H
    Radiol Phys Technol; 2021 Mar; 14(1):57-63. PubMed ID: 33393057
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases.
    Cui T; Zhou Y; Yue NJ; Vergalasova I; Zhang Y; Zhu J; Nie K
    Med Phys; 2021 Dec; 48(12):7632-7640. PubMed ID: 34655249
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multicomponent mathematical model for tumor volume calculation with setup error using single-isocenter stereotactic radiotherapy for multiple brain metastases.
    Nakano H; Shiinoki T; Tanabe S; Nakano T; Takizawa T; Utsunomiya S; Sakai M; Tanabe S; Ohta A; Kaidu M; Nishio T; Ishikawa H
    Phys Eng Sci Med; 2023 Jun; 46(2):945-953. PubMed ID: 36940064
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predicting the effect of indirect cell kill in the treatment of multiple brain metastases via single-isocenter/multitarget volumetric modulated arc therapy stereotactic radiosurgery.
    Palmiero AN; Fabian D; Randall ME; Clair W; Pokhrel D
    J Appl Clin Med Phys; 2021 Oct; 22(10):94-103. PubMed ID: 34498359
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage.
    Roper J; Chanyavanich V; Betzel G; Switchenko J; Dhabaan A
    Int J Radiat Oncol Biol Phys; 2015 Nov; 93(3):540-6. PubMed ID: 26460996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Management of multiple brain metastases via dual-isocenter VMAT stereotactic radiosurgery.
    Palmiero AN; Fabian D; St Clair W; Randall M; Pokhrel D
    Med Dosim; 2021 Autumn; 46(3):240-246. PubMed ID: 33549397
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-Isocenter Volumetric Modulated Arc Therapy (VMAT) Radiosurgery for Multiple Brain Metastases: Potential Loss of Target(s) Coverage Due to Isocenter Misalignment.
    Palmiero AN; Critchfield L; St Clair W; Randall M; Pokhrel D
    Cureus; 2020 Oct; 12(10):e11267. PubMed ID: 33274143
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique.
    Ruggieri R; Naccarato S; Mazzola R; Ricchetti F; Corradini S; Fiorentino A; Alongi F
    Radiat Oncol; 2018 Mar; 13(1):38. PubMed ID: 29506539
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques.
    Prentou G; Pappas EP; Logothetis A; Koutsouveli E; Pantelis E; Papagiannis P; Karaiskos P
    J Appl Clin Med Phys; 2020 Mar; 21(3):32-44. PubMed ID: 32022447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Frame-based radiosurgery of multiple metastases using single-isocenter volumetric modulated arc therapy technique.
    Ahn KH; Yenice KM; Koshy M; Slavin KV; Aydogan B
    J Appl Clin Med Phys; 2019 Aug; 20(8):21-28. PubMed ID: 31328368
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Selection of single-isocenter for multiple-target stereotactic brain radiosurgery to minimize total margin volume.
    Slagowski JM; Wen Z
    Phys Med Biol; 2020 Sep; 65(18):185012. PubMed ID: 32460254
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of correlation between intrafractional residual setup errors and accumulation of delivered dose distributions in single isocenter volumetric modulated arc therapy for multiple brain metastases.
    Tsuruta Y; Nakamura M; Nakata M; Hirashima H; Zhou D; Uto M; Takehana K; Fujimoto T; Mizowaki T
    Phys Med; 2022 Jun; 98():45-52. PubMed ID: 35490529
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric Effect of Rotational Setup Errors in Single-Isocenter Volumetric-Modulated Arc Therapy of Multiple Brain Metastases.
    Selvan KT; Padma G; Revathy MK; Nambi Raj NA; Senthilnathan K; Babu PR
    J Med Phys; 2019; 44(2):84-90. PubMed ID: 31359925
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single-isocenter stereotactic radiosurgery for multiple brain metastases: Impact of patient misalignments on target coverage in non-coplanar treatments.
    Eder MM; Reiner M; Heinz C; Garny S; Freislederer P; Landry G; Niyazi M; Belka C; Riboldi M
    Z Med Phys; 2022 Aug; 32(3):296-311. PubMed ID: 35504799
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Combined effect of dose gradient and rotational error on prescribed dose coverage for single isocenter multiple brain metastases in frameless stereotactic radiotherapy.
    Yoon JW; Park S; Cheong KH; Kang SK; Han TJ
    Radiat Oncol; 2021 Aug; 16(1):169. PubMed ID: 34465331
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk of target coverage loss for stereotactic body radiotherapy treatment of synchronous lung lesions via single-isocenter volumetric modulated arc therapy.
    Critchfield LC; Bernard ME; Randall ME; McGarry RC; Pokhrel D
    J Appl Clin Med Phys; 2021 Jan; 22(1):251-260. PubMed ID: 33342042
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric comparison of multiple vs single isocenter technique for linear accelerator-based stereotactic radiosurgery: The Importance of the six degree couch.
    Amaya D; Shinde A; Wohlers C; Wong KCC; Novak J; Neylon J; Han C; Liu A; Dandapani S; Glaser S
    J Appl Clin Med Phys; 2021 Jun; 22(6):45-49. PubMed ID: 34021698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A statistical model for analyzing the rotational error of single isocenter for multiple targets technique.
    Chang J
    Med Phys; 2017 Jun; 44(6):2115-2123. PubMed ID: 28382761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.