BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

238 related articles for article (PubMed ID: 33122200)

  • 1. Gadolinium-Enhanced 3D T1-Weighted Black-Blood MR Imaging for the Detection of Acute Optic Neuritis.
    Riederer I; Sollmann N; Mühlau M; Zimmer C; Kirschke JS
    AJNR Am J Neuroradiol; 2020 Dec; 41(12):2333-2338. PubMed ID: 33122200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of Acute Optic Neuritis using Contrast-Enhanced 3-Dimensional Cube T1-Weighted Imaging: A Preliminary Study.
    Yang R; Qu B; Liu WV; Liu C; Chen T; Li L; Zha Y
    Comb Chem High Throughput Screen; 2023; 26(8):1480-1487. PubMed ID: 36017841
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved Lesion Conspicuity with Contrast-Enhanced 3D T1 TSE Black-Blood Imaging in Cranial Neuritis: A Comparative Study of Contrast-Enhanced 3D T1 TSE, 3D T1 Fast-Spoiled Gradient Echo, and 3D T2 FLAIR.
    Baek TW; Kang Y; Lee HJ
    AJNR Am J Neuroradiol; 2021 May; 42(5):945-950. PubMed ID: 33707287
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluating the Utility of a Postprocessing Algorithm for MRI Evaluation of Optic Neuritis.
    Stunkel L; Sharma A; Parsons MS; Salter A; Van Stavern GP
    AJNR Am J Neuroradiol; 2019 Jun; 40(6):1043-1048. PubMed ID: 31048299
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical application of 3D VIBECAIPI-DIXON for non-enhanced imaging of the pancreas compared to a standard 2D fat-saturated FLASH.
    Haneder S; Koziel K; Morelli JN; Riffel P; Budjan J; Schoenberg SO; Michaely HJ
    Clin Imaging; 2014; 38(2):142-7. PubMed ID: 24332974
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic value of contrast-enhanced 3D FLAIR sequence in acute optic neuritis.
    Panyaping T; Tunlayadechanont P; Jindahra P; Cheecharoen P
    Neuroradiol J; 2023 Dec; 36(6):674-679. PubMed ID: 37205609
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MR diagnosis of facial neuritis: diagnostic performance of contrast-enhanced 3D-FLAIR technique compared with contrast-enhanced 3D-T1-fast-field echo with fat suppression.
    Lim HK; Lee JH; Hyun D; Park JW; Kim JL; Lee Hy; Park S; Ahn JH; Baek JH; Choi CG
    AJNR Am J Neuroradiol; 2012 Apr; 33(4):779-83. PubMed ID: 22207300
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.
    Fukuoka H; Hirai T; Okuda T; Shigematsu Y; Sasao A; Kimura E; Hirano T; Yano S; Murakami R; Yamashita Y
    AJNR Am J Neuroradiol; 2010 May; 31(5):868-73. PubMed ID: 20037130
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MR imaging of the inner ear and cerebellopontine angle: comparison of three-dimensional and two-dimensional sequences.
    Czerny C; Rand T; Gstoettner W; Woelfl G; Imhof H; Trattnig S
    AJR Am J Roentgenol; 1998 Mar; 170(3):791-6. PubMed ID: 9490977
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of routine fat-suppressed FLAIR and diffusion-weighted images in detecting clinically evident acute optic neuritis.
    McKinney AM; Lohman BD; Sarikaya B; Benson M; Lee MS; Benson MT
    Acta Radiol; 2013 May; 54(4):455-61. PubMed ID: 23386735
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of contrast-enhanced modified T1-weighted 3D TSE black-blood and 3D MP-RAGE sequences for the detection of cerebral metastases and brain tumours.
    Kammer NN; Coppenrath E; Treitl KM; Kooijman H; Dietrich O; Saam T
    Eur Radiol; 2016 Jun; 26(6):1818-25. PubMed ID: 26334511
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI.
    Goncalves Filho ALM; Awan KM; Conklin J; Ngamsombat C; Cauley SF; Setsompop K; Liu W; Splitthoff DN; Lo WC; Kirsch JE; Schaefer PW; Rapalino O; Huang SY
    Eur Radiol; 2023 Apr; 33(4):2905-2915. PubMed ID: 36460923
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging, and two-dimensional navigator-based reacquisition in detecting acute optic neuritis.
    Wan H; Sha Y; Zhang F; Hong R; Tian G; Fan H
    J Magn Reson Imaging; 2016 Mar; 43(3):655-60. PubMed ID: 26251130
    [TBL] [Abstract][Full Text] [Related]  

  • 14. T1-weighted 3D dynamic contrast-enhanced MRI of the breast using a dual-echo Dixon technique at 3 T.
    Dogan BE; Ma J; Hwang K; Liu P; Yang WT
    J Magn Reson Imaging; 2011 Oct; 34(4):842-51. PubMed ID: 21769987
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of Optic Neuritis on Routine Brain MRI without and with the Assistance of an Image Postprocessing Algorithm.
    Schroeder A; Van Stavern G; Orlowski HLP; Stunkel L; Parsons MS; Rhea L; Sharma A
    AJNR Am J Neuroradiol; 2021 Jun; 42(6):1130-1135. PubMed ID: 33737263
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of Thick-Slab Overlapping MIP Images of Contrast-Enhanced 3D T1-Weighted CUBE for Detection of Intracranial Metastases: A Pilot Study for Comparison of Lesion Detection, Interpretation Time, and Sensitivity with Nonoverlapping CUBE MIP, CUBE, and Inversion-Recovery-Prepared Fast-Spoiled Gradient Recalled Brain Volume.
    Yoon BC; Saad AF; Rezaii P; Wintermark M; Zaharchuk G; Iv M
    AJNR Am J Neuroradiol; 2018 Sep; 39(9):1635-1642. PubMed ID: 30093483
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fat-suppressed, three-dimensional T1-weighted imaging using high-acceleration parallel acquisition and a dual-echo Dixon technique for gadoxetic acid-enhanced liver MRI at 3 T.
    Yoon JH; Lee JM; Yu MH; Kim EJ; Han JK; Choi BI
    Acta Radiol; 2015 Dec; 56(12):1454-62. PubMed ID: 25480475
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CS-VIBE accelerates cranial nerve MR imaging for the diagnosis of facial neuritis: comparison of the diagnostic performance of post-contrast MPRAGE and CS-VIBE.
    Chung MS; Yim Y; Sung JK; Kim I; Nickel D; Chang M; Mun SK; Byun JS
    Eur Radiol; 2022 Jan; 32(1):223-233. PubMed ID: 34156555
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of 3D Fast Spin-Echo T1 Black-Blood Imaging in the Diagnosis and Prognostic Prediction of Patients with Leptomeningeal Carcinomatosis.
    Oh J; Choi SH; Lee E; Shin DJ; Jo SW; Yoo RE; Kang KM; Yun TJ; Kim JH; Sohn CH
    AJNR Am J Neuroradiol; 2018 Aug; 39(8):1453-1459. PubMed ID: 30002052
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Clinical and imaging characteristics of optic nerve tumors as the differencial diagnosis of optic neuritis].
    Sun CB; Jiang B; Liu GH; Xiao Q
    Zhonghua Yan Ke Za Zhi; 2023 May; 59(5):367-375. PubMed ID: 37151005
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 12.