These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 33128609)
1. Can 3D-printing avoid discomfort-related implant removal in midshaft clavicle fractures? A four-year follow-up. van Doremalen RFM; van der Linde RA; Kootstra JJ; van Helden SH; Hekman EEG Arch Orthop Trauma Surg; 2021 Nov; 141(11):1899-1907. PubMed ID: 33128609 [TBL] [Abstract][Full Text] [Related]
2. Precontoured dynamic compression plate using patient-specific 3D-printed models in minimally invasive surgical technique for midshaft clavicle fractures. Jirangkul P; Lorsuwannarat N; Wanichjaroen N Arch Orthop Trauma Surg; 2024 Jan; 144(1):103-111. PubMed ID: 37658855 [TBL] [Abstract][Full Text] [Related]
3. Prognostic Factors for Reoperation After Plate Fixation of the Midshaft Clavicle. Schemitsch LA; Schemitsch EH; Kuzyk P; McKee MD J Orthop Trauma; 2015 Dec; 29(12):533-7. PubMed ID: 26131565 [TBL] [Abstract][Full Text] [Related]
4. Are clinical outcomes affected by type of plate used for management of mid-shaft clavicle fractures? Alzahrani MM; Cota A; Alkhelaifi K; Aleidan A; Berry G; Reindl R; Harvey E J Orthop Traumatol; 2018 Aug; 19(1):8. PubMed ID: 30112628 [TBL] [Abstract][Full Text] [Related]
5. Complications After Plate Fixation of Displaced Pediatric Midshaft Clavicle Fractures. Li Y; Helvie P; Farley FA; Abbott MD; Caird MS J Pediatr Orthop; 2018 Aug; 38(7):350-353. PubMed ID: 27379787 [TBL] [Abstract][Full Text] [Related]
6. High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures. Hulsmans MH; van Heijl M; Houwert RM; Hammacher ER; Meylaerts SA; Verhofstad MH; Dijkgraaf MG; Verleisdonk EJ Clin Orthop Relat Res; 2017 Feb; 475(2):532-539. PubMed ID: 27830484 [TBL] [Abstract][Full Text] [Related]
7. Prognostic factors and outcomes of secondary surgery after plate fixation for midshaft clavicle fracture: Comparison of traditional DCP and pre-contoured locking plate. Hsiao YC; Lin TY; Wang YC; Chang CW; Tang HC; Chen CH; Su CY Injury; 2020 Oct; 51(10):2241-2244. PubMed ID: 32616334 [TBL] [Abstract][Full Text] [Related]
8. No Difference in Risk of Implant Removal Between Orthogonal Mini-fragment and Single Small-fragment Plating of Midshaft Clavicle Fractures in a Military Population: A Preliminary Study. Lee C; Feaker DA; Ostrofe AA; Smith CS Clin Orthop Relat Res; 2020 Apr; 478(4):741-749. PubMed ID: 32229745 [TBL] [Abstract][Full Text] [Related]
10. The first 100 patients treated with a new anatomical pre-contoured locking plate for clavicular midshaft fractures. Reisch T; Camenzind RS; Fuhrer R; Riede U; Helmy N BMC Musculoskelet Disord; 2019 Jan; 20(1):4. PubMed ID: 30611253 [TBL] [Abstract][Full Text] [Related]
11. Use of a real-size 3D-printed model as a preoperative and intraoperative tool for minimally invasive plating of comminuted midshaft clavicle fractures. Kim HN; Liu XN; Noh KC J Orthop Surg Res; 2015 Jun; 10():91. PubMed ID: 26054648 [TBL] [Abstract][Full Text] [Related]
12. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis. Chan G; Korac Z; Miletic M; Vidovic D; Phadnis J; Bakota B Injury; 2017 Nov; 48 Suppl 5():S21-S26. PubMed ID: 29122117 [TBL] [Abstract][Full Text] [Related]
13. Complications after surgical treatment of distal clavicle fractures. Singh A; Schultzel M; Fleming JF; Navarro RA Orthop Traumatol Surg Res; 2019 Sep; 105(5):853-859. PubMed ID: 31202717 [TBL] [Abstract][Full Text] [Related]
14. Plate fixation of midshaft clavicular fractures: patient-reported outcomes and hardware-related complications. Naimark M; Dufka FL; Han R; Sing DC; Toogood P; Ma CB; Zhang AL; Feeley BT J Shoulder Elbow Surg; 2016 May; 25(5):739-46. PubMed ID: 26700553 [TBL] [Abstract][Full Text] [Related]
15. Surgical Treatment of Displaced Midshaft Clavicle Fractures: Precontoured Plates Versus Noncontoured Plates. Rongguang A; Zhen J; Jianhua Z; Jifei S; Xinhua J; Baoqing Y J Hand Surg Am; 2016 Sep; 41(9):e263-6. PubMed ID: 27497801 [TBL] [Abstract][Full Text] [Related]
16. Midshaft Fractures of the Clavicle: A Meta-analysis Comparing Surgical Fixation Using Anteroinferior Plating Versus Superior Plating. Nourian A; Dhaliwal S; Vangala S; Vezeridis PS J Orthop Trauma; 2017 Sep; 31(9):461-467. PubMed ID: 28708779 [TBL] [Abstract][Full Text] [Related]
17. Comparative analysis of functional outcome of anatomical precontoured locking plate versus reconstruction plate in the management of displaced midshaft clavicular fractures. Kingsly P; Sathish M; Ismail NDM J Orthop Surg (Hong Kong); 2019; 27(1):2309499018820351. PubMed ID: 30798707 [TBL] [Abstract][Full Text] [Related]
18. Plate fixation or intramedullary fixation for midshaft clavicle fractures: a systematic review and meta-analysis of randomized controlled trials and observational studies. Houwert RM; Smeeing DP; Ahmed Ali U; Hietbrink F; Kruyt MC; van der Meijden OA J Shoulder Elbow Surg; 2016 Jul; 25(7):1195-203. PubMed ID: 27068381 [TBL] [Abstract][Full Text] [Related]
19. Dual Plate Minifragment Fixation of Clavicle Fractures- Technique and Approach. Zielinski E; Doe K; Perdue P J Orthop Trauma; 2022 Aug; 36(Suppl 3):S1-S2. PubMed ID: 35838561 [TBL] [Abstract][Full Text] [Related]
20. Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures. Ashman BD; Slobogean GP; Stone TB; Viskontas DG; Moola FO; Perey BH; Boyer DS; McCormack RG Injury; 2014 Oct; 45(10):1549-53. PubMed ID: 24893919 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]