207 related articles for article (PubMed ID: 33140884)
21. [New Colonoscopy Devices to Improve Colon Neoplasm Detection].
Shin SJ
Korean J Gastroenterol; 2016 Dec; 68(6):293-296. PubMed ID: 28025471
[TBL] [Abstract][Full Text] [Related]
22. AmplifEYE assisted colonoscopy versus standard colonoscopy: A randomized controlled study.
Sze SF; Cheung WI; Wong WC; Hui YT; Lam JTW
J Gastroenterol Hepatol; 2021 Feb; 36(2):376-382. PubMed ID: 33141979
[TBL] [Abstract][Full Text] [Related]
23. Meta-analysis indicates that add-on devices and new endoscopes reduce colonoscopy adenoma miss rate.
Gkolfakis P; Tziatzios G; Facciorusso A; Muscatiello N; Triantafyllou K
Eur J Gastroenterol Hepatol; 2018 Dec; 30(12):1482-1490. PubMed ID: 30188409
[TBL] [Abstract][Full Text] [Related]
24. Diagnostic yield and miss rate of EndoRings in an organized colorectal cancer screening program: the SMART (Study Methodology for ADR-Related Technology) trial.
Hassan C; Senore C; Manes G; Fuccio L; Iacopini F; Ricciardiello L; Anderloni A; Frazzoni L; Ballanti R; de Nucci G; Colussi D; Redaelli D; Lorenzetti R; Devani M; Arena I; Grossi C; Andrei F; Balestrazzi E; Sharma P; Rex DK; Repici A
Gastrointest Endosc; 2019 Mar; 89(3):583-590.e1. PubMed ID: 30365984
[TBL] [Abstract][Full Text] [Related]
25. Improved detection of adenomas and sessile serrated polyps is maintained with continuous audit of colonoscopy.
Fraser AG; Rose T; Wong P; Lane M; Frankish P
BMJ Open Gastroenterol; 2020 Jul; 7(1):. PubMed ID: 32675086
[TBL] [Abstract][Full Text] [Related]
26. Water infusion versus air insufflation for colonoscopy.
Hafner S; Zolk K; Radaelli F; Otte J; Rabenstein T; Zolk O
Cochrane Database Syst Rev; 2015 May; (5):CD009863. PubMed ID: 26011829
[TBL] [Abstract][Full Text] [Related]
27. Improving serrated adenoma detection rate in the colon by electronic chromoendoscopy and distal attachment: systematic review and meta-analysis.
Aziz M; Desai M; Hassan S; Fatima R; Dasari CS; Chandrasekar VT; Jegadeesan R; Duvvuri A; Patel H; Rai T; Sathyamurthy A; Kohli DR; Vennalaganti P; Nawras A; Wallace M; Sharma P
Gastrointest Endosc; 2019 Nov; 90(5):721-731.e1. PubMed ID: 31288029
[TBL] [Abstract][Full Text] [Related]
28. EndoCuff-assisted colonoscopy could improve adenoma detection rate: A meta-analysis of randomized controlled trials.
Jian HX; Feng BC; Zhang Y; Qu JY; Li YY; Zuo XL
J Dig Dis; 2019 Nov; 20(11):578-588. PubMed ID: 31429214
[TBL] [Abstract][Full Text] [Related]
29. Randomized controlled trial of EndoRings assisted colonoscopy versus standard colonoscopy.
Thayalasekaran S; Bhattacharyya R; Chedgy F; Basford P; Subramaniam S; Kandiah K; Thursby-Pelham F; Brown J; Alkandari A; Ellis R; Coda S; Goggin P; Amos M; Fogg C; Longcroft-Wheaton G; Bhandari P
Dig Endosc; 2023 Mar; 35(3):354-360. PubMed ID: 36085410
[TBL] [Abstract][Full Text] [Related]
30. Narrow-band imaging versus white light for the detection of proximal colon serrated lesions: a randomized, controlled trial.
Rex DK; Clodfelter R; Rahmani F; Fatima H; James-Stevenson TN; Tang JC; Kim HN; McHenry L; Kahi CJ; Rogers NA; Helper DJ; Sagi SV; Kessler WR; Wo JM; Fischer M; Kwo PY
Gastrointest Endosc; 2016 Jan; 83(1):166-71. PubMed ID: 25952085
[TBL] [Abstract][Full Text] [Related]
31. Cimetropium bromide does not improve polyp and adenoma detection during colonoscope withdrawal: A randomized, double-blind, placebo-controlled study.
Jung P; Park SB; Kim HW; Kang DH; W Choi C; Kim SJ; Nam HS; Ryu DG; Hong JB; Kim DJ
Medicine (Baltimore); 2018 Jun; 97(25):e11253. PubMed ID: 29924056
[TBL] [Abstract][Full Text] [Related]
32. High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: a meta-analysis.
Subramanian V; Mannath J; Hawkey CJ; Ragunath K
Endoscopy; 2011 Jun; 43(6):499-505. PubMed ID: 21360420
[TBL] [Abstract][Full Text] [Related]
33. Relationship of colonoscopy-detected serrated polyps with synchronous advanced neoplasia in average-risk individuals.
Álvarez C; Andreu M; Castells A; Quintero E; Bujanda L; Cubiella J; Salas D; Lanas Á; Carballo F; Morillas JD; Hernández C; Jover R; Sarasqueta C; Enriquéz-Navascués JM; Hernández V; Estévez P; Macenlle R; Sala T; Balaguer F; Pellisé M; Moreira L; Gil I; Peris A; González-Rubio F; Ferrández A; Poves C; Ponce M; Grau J; Serradesanferm A; Ono A; Cruzado J; Pérez-Riquelme F; Alonso-Abreu I; Carrillo-Palau M; Santander C; Díaz Tasende J; Herreros A; Cacho G; Barranco LE; Bessa X;
Gastrointest Endosc; 2013 Aug; 78(2):333-341.e1. PubMed ID: 23623039
[TBL] [Abstract][Full Text] [Related]
34. Meta-analysis of narrow-band imaging versus conventional colonoscopy for adenoma detection.
Dinesen L; Chua TJ; Kaffes AJ
Gastrointest Endosc; 2012 Mar; 75(3):604-11. PubMed ID: 22341105
[TBL] [Abstract][Full Text] [Related]
35. Screening Colonoscopy Withdrawal Time Threshold for Adequate Proximal Serrated Polyp Detection Rate.
Patel VD; Thompson WK; Lapin BR; Goldstein JL; Yen EF
Dig Dis Sci; 2018 Nov; 63(11):3084-3090. PubMed ID: 29974376
[TBL] [Abstract][Full Text] [Related]
36. A novel method with significant impact on adenoma detection: combined water-exchange and cap-assisted colonoscopy.
Yen AW; Leung JW; Leung FW
Gastrointest Endosc; 2013 Jun; 77(6):944-8. PubMed ID: 23473001
[TBL] [Abstract][Full Text] [Related]
37. Computer-aided detection versus advanced imaging for detection of colorectal neoplasia: a systematic review and network meta-analysis.
Spadaccini M; Iannone A; Maselli R; Badalamenti M; Desai M; Chandrasekar VT; Patel HK; Fugazza A; Pellegatta G; Galtieri PA; Lollo G; Carrara S; Anderloni A; Rex DK; Savevski V; Wallace MB; Bhandari P; Roesch T; Gralnek IM; Sharma P; Hassan C; Repici A
Lancet Gastroenterol Hepatol; 2021 Oct; 6(10):793-802. PubMed ID: 34363763
[TBL] [Abstract][Full Text] [Related]
38. Training interventions to improve adenoma detection rates during colonoscopy: a systematic review and meta-analysis.
Lim S; Hammond S; Park J; Hochman D; Lê ML; Rabbani R; Abou-Setta A; Zarychanski R
Surg Endosc; 2020 Sep; 34(9):3870-3882. PubMed ID: 31595401
[TBL] [Abstract][Full Text] [Related]
39. Cap-Assisted Colonoscopy Increases Detection of Advanced Adenomas and Polyps.
Othman MO; Zhang D; Elhanafi S; Eloliby M; Davis B; Guererro R; Alvarado L; Sanchez L; Dwivedi A; Zuckerman MJ
Am J Med Sci; 2017 Apr; 353(4):367-373. PubMed ID: 28317624
[TBL] [Abstract][Full Text] [Related]
40. Panchromoendoscopy Increases Detection of Polyps in Patients With Serrated Polyposis Syndrome.
López-Vicente J; Rodríguez-Alcalde D; Hernández L; Riu Pons F; Vega P; Herrero Rivas JM; Santiago García J; Salces Franco I; Bustamante Balén M; López-Cerón M; Pellisé M;
Clin Gastroenterol Hepatol; 2019 Sep; 17(10):2016-2023.e6. PubMed ID: 30366156
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]