785 related articles for article (PubMed ID: 33147214)
1. Development and evaluation of a rapid and simple diagnostic assay for COVID-19 based on loop-mediated isothermal amplification.
Yoshikawa R; Abe H; Igasaki Y; Negishi S; Goto H; Yasuda J
PLoS Negl Trop Dis; 2020 Nov; 14(11):e0008855. PubMed ID: 33147214
[TBL] [Abstract][Full Text] [Related]
2. Development and Clinical Application of a Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for SARS-CoV-2 Infection.
Hu X; Deng Q; Li J; Chen J; Wang Z; Zhang X; Fang Z; Li H; Zhao Y; Yu P; Li W; Wang X; Li S; Zhang L; Hou T
mSphere; 2020 Aug; 5(4):. PubMed ID: 32848011
[TBL] [Abstract][Full Text] [Related]
3. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay.
Yan C; Cui J; Huang L; Du B; Chen L; Xue G; Li S; Zhang W; Zhao L; Sun Y; Yao H; Li N; Zhao H; Feng Y; Liu S; Zhang Q; Liu D; Yuan J
Clin Microbiol Infect; 2020 Jun; 26(6):773-779. PubMed ID: 32276116
[TBL] [Abstract][Full Text] [Related]
4. Rapid point-of-care detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP).
Mautner L; Baillie CK; Herold HM; Volkwein W; Guertler P; Eberle U; Ackermann N; Sing A; Pavlovic M; Goerlich O; Busch U; Wassill L; Huber I; Baiker A
Virol J; 2020 Oct; 17(1):160. PubMed ID: 33087160
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of rapid diagnosis of novel coronavirus disease (COVID-19) using loop-mediated isothermal amplification.
Kitagawa Y; Orihara Y; Kawamura R; Imai K; Sakai J; Tarumoto N; Matsuoka M; Takeuchi S; Maesaki S; Maeda T
J Clin Virol; 2020 Aug; 129():104446. PubMed ID: 32512376
[TBL] [Abstract][Full Text] [Related]
6. iSCAN: An RT-LAMP-coupled CRISPR-Cas12 module for rapid, sensitive detection of SARS-CoV-2.
Ali Z; Aman R; Mahas A; Rao GS; Tehseen M; Marsic T; Salunke R; Subudhi AK; Hala SM; Hamdan SM; Pain A; Alofi FS; Alsomali A; Hashem AM; Khogeer A; Almontashiri NAM; Abedalthagafi M; Hassan N; Mahfouz MM
Virus Res; 2020 Oct; 288():198129. PubMed ID: 32822689
[TBL] [Abstract][Full Text] [Related]
7. A Rapid, Simple, Inexpensive, and Mobile Colorimetric Assay COVID-19-LAMP for Mass On-Site Screening of COVID-19.
Chow FW; Chan TT; Tam AR; Zhao S; Yao W; Fung J; Cheng FK; Lo GC; Chu S; Aw-Yong KL; Tang JY; Tsang CC; Luk HK; Wong AC; Li KS; Zhu L; He Z; Tam EWT; Chung TW; Wong SCY; Que TL; Fung KS; Lung DC; Wu AK; Hung IF; Woo PC; Lau SK
Int J Mol Sci; 2020 Jul; 21(15):. PubMed ID: 32751106
[TBL] [Abstract][Full Text] [Related]
8. Detecting SARS-CoV-2 at point of care: preliminary data comparing loop-mediated isothermal amplification (LAMP) to polymerase chain reaction (PCR).
Österdahl MF; Lee KA; Lochlainn MN; Wilson S; Douthwaite S; Horsfall R; Sheedy A; Goldenberg SD; Stanley CJ; Spector TD; Steves CJ
BMC Infect Dis; 2020 Oct; 20(1):783. PubMed ID: 33081710
[TBL] [Abstract][Full Text] [Related]
9. Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2.
Baek YH; Um J; Antigua KJC; Park JH; Kim Y; Oh S; Kim YI; Choi WS; Kim SG; Jeong JH; Chin BS; Nicolas HDG; Ahn JY; Shin KS; Choi YK; Park JS; Song MS
Emerg Microbes Infect; 2020 Dec; 9(1):998-1007. PubMed ID: 32306853
[TBL] [Abstract][Full Text] [Related]
10. Loop mediated isothermal amplification (LAMP) assays as a rapid diagnostic for COVID-19.
Kashir J; Yaqinuddin A
Med Hypotheses; 2020 Aug; 141():109786. PubMed ID: 32361529
[TBL] [Abstract][Full Text] [Related]
11. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples.
Dao Thi VL; Herbst K; Boerner K; Meurer M; Kremer LP; Kirrmaier D; Freistaedter A; Papagiannidis D; Galmozzi C; Stanifer ML; Boulant S; Klein S; Chlanda P; Khalid D; Barreto Miranda I; Schnitzler P; Kräusslich HG; Knop M; Anders S
Sci Transl Med; 2020 Aug; 12(556):. PubMed ID: 32719001
[TBL] [Abstract][Full Text] [Related]
12. Development and Validation of a Rapid, Single-Step Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) System Potentially to Be Used for Reliable and High-Throughput Screening of COVID-19.
Jiang M; Pan W; Arasthfer A; Fang W; Ling L; Fang H; Daneshnia F; Yu J; Liao W; Pei H; Li X; Lass-Flörl C
Front Cell Infect Microbiol; 2020; 10():331. PubMed ID: 32626666
[No Abstract] [Full Text] [Related]
13. Artificial Intelligence-Assisted Loop Mediated Isothermal Amplification (AI-LAMP) for Rapid Detection of SARS-CoV-2.
Rohaim MA; Clayton E; Sahin I; Vilela J; Khalifa ME; Al-Natour MQ; Bayoumi M; Poirier AC; Branavan M; Tharmakulasingam M; Chaudhry NS; Sodi R; Brown A; Burkhart P; Hacking W; Botham J; Boyce J; Wilkinson H; Williams C; Whittingham-Dowd J; Shaw E; Hodges M; Butler L; Bates MD; La Ragione R; Balachandran W; Fernando A; Munir M
Viruses; 2020 Sep; 12(9):. PubMed ID: 32883050
[TBL] [Abstract][Full Text] [Related]
14. Rapid detection of novel coronavirus/Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by reverse transcription-loop-mediated isothermal amplification.
Lamb LE; Bartolone SN; Ward E; Chancellor MB
PLoS One; 2020; 15(6):e0234682. PubMed ID: 32530929
[TBL] [Abstract][Full Text] [Related]
15. Rapid isothermal amplification and portable detection system for SARS-CoV-2.
Ganguli A; Mostafa A; Berger J; Aydin MY; Sun F; Ramirez SAS; Valera E; Cunningham BT; King WP; Bashir R
Proc Natl Acad Sci U S A; 2020 Sep; 117(37):22727-22735. PubMed ID: 32868442
[TBL] [Abstract][Full Text] [Related]
16. Validation of a single-step, single-tube reverse transcription loop-mediated isothermal amplification assay for rapid detection of SARS-CoV-2 RNA.
Lee JYH; Best N; McAuley J; Porter JL; Seemann T; Schultz MB; Sait M; Orlando N; Mercoulia K; Ballard SA; Druce J; Tran T; Catton MG; Pryor MJ; Cui HL; Luttick A; McDonald S; Greenhalgh A; Kwong JC; Sherry NL; Graham M; Hoang T; Herisse M; Pidot SJ; Williamson DA; Howden BP; Monk IR; Stinear TP
J Med Microbiol; 2020 Sep; 69(9):1169-1178. PubMed ID: 32755529
[No Abstract] [Full Text] [Related]
17. Rapid Detection of COVID-19 Coronavirus Using a Reverse Transcriptional Loop-Mediated Isothermal Amplification (RT-LAMP) Diagnostic Platform.
Yu L; Wu S; Hao X; Dong X; Mao L; Pelechano V; Chen WH; Yin X
Clin Chem; 2020 Jul; 66(7):975-977. PubMed ID: 32315390
[No Abstract] [Full Text] [Related]
18. SARS-CoV-2 detection using isothermal amplification and a rapid, inexpensive protocol for sample inactivation and purification.
Rabe BA; Cepko C
Proc Natl Acad Sci U S A; 2020 Sep; 117(39):24450-24458. PubMed ID: 32900935
[TBL] [Abstract][Full Text] [Related]
19. Rapid Detection of SARS-CoV-2 by Low Volume Real-Time Single Tube Reverse Transcription Recombinase Polymerase Amplification Using an Exo Probe with an Internally Linked Quencher (Exo-IQ).
Behrmann O; Bachmann I; Spiegel M; Schramm M; Abd El Wahed A; Dobler G; Dame G; Hufert FT
Clin Chem; 2020 Aug; 66(8):1047-1054. PubMed ID: 32384153
[TBL] [Abstract][Full Text] [Related]
20. Optimization and clinical validation of dual-target RT-LAMP for SARS-CoV-2.
Mohon AN; Oberding L; Hundt J; van Marle G; Pabbaraju K; Berenger BM; Lisboa L; Griener T; Czub M; Doolan C; Servellita V; Chiu CY; Greninger AL; Jerome KR; Pillai DR
J Virol Methods; 2020 Dec; 286():113972. PubMed ID: 32941977
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]