These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 33150403)

  • 1. Heat production during pulmonary artery sealing with energy vessel-sealing devices in a swine model.
    Goudie E; Oliveira R; Thiffault V; Jouquan A; Hadjeres R; Berdugo J; Ferraro P; Liberman M
    Interact Cardiovasc Thorac Surg; 2020 Dec; 31(6):847-852. PubMed ID: 33150403
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Phase 1 Trial Evaluating Safety of Pulmonary Artery Sealing With Ultrasonic Energy in VATS Lobectomy.
    Goudie E; Oliveira RL; Thiffault V; Jouquan A; Lafontaine E; Ferraro P; Liberman M
    Ann Thorac Surg; 2018 Jan; 105(1):214-220. PubMed ID: 29157742
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulmonary artery sealing with ultrasonic energy in open lobectomy: A phase I clinical trial.
    Goudie E; Thiffault V; Jouquan A; Lafontaine E; Ferraro P; Liberman M
    J Thorac Cardiovasc Surg; 2017 Jun; 153(6):1600-1607. PubMed ID: 28526110
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulmonary Artery Sealing With an Ultrasonic Energy Device in Video-Assisted Thoracoscopic Surgery Lobectomy: An Animal Survival Study.
    Goudie E; Khereba M; Tahiri M; Hegde P; Thiffault V; Hadjeres R; Berdugo J; Ferraro P; Liberman M
    Ann Thorac Surg; 2016 Oct; 102(4):1088-94. PubMed ID: 27345091
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulmonary Artery Sealing Using the HARMONIC ACE+ Shears for Video-Assisted Thoracoscopic Surgery Lobectomy.
    Liberman M; Khereba M; Nasir B; Goudie E; Danino A; Giot JP; Nizard N; Hadjeres R; Thiffault V; Farrenq N; Ferraro P
    Ann Thorac Surg; 2015 Sep; 100(3):898-903; discussion 903-4. PubMed ID: 26209484
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Differential response of arteries and veins to bipolar vessel sealing: evaluation of a novel reusable device.
    Richter S; Kollmar O; Neunhoeffer E; Schilling MK; Menger MD; Pistorius G
    J Laparoendosc Adv Surg Tech A; 2006 Apr; 16(2):149-55. PubMed ID: 16646707
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy and quality of vessel sealing: comparison of a reusable with a disposable device and effects of clamp surface geometry and structure.
    Richter S; Kollmar O; Schilling MK; Pistorius GA; Menger MD
    Surg Endosc; 2006 Jun; 20(6):890-4. PubMed ID: 16738977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental study in pulmonary artery sealing with a vessel-sealing device.
    Yamada T; Sowa T; Bando T; Date H
    Asian Cardiovasc Thorac Ann; 2016 Jul; 24(6):562-7. PubMed ID: 27273231
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The nightknife©: evaluation of efficiency and quality of bipolar vessel sealing.
    Schuld J; Sperling J; Kollmar O; Menger MD; Schilling MK; Richter S; Laschke MW
    J Laparoendosc Adv Surg Tech A; 2011 Sep; 21(7):659-63. PubMed ID: 21774696
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PlasmaKinetic bipolar vessel sealing: burst pressures and thermal spread in an animal model.
    Pietrow PK; Weizer AZ; L'Esperance JO; Auge BK; Silverstein A; Cummings T; Preminger GM; Albala DM
    J Endourol; 2005; 19(1):107-10. PubMed ID: 15735394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices.
    Chen J; Jensen CR; Manwaring PK; Glasgow RE
    Surg Laparosc Endosc Percutan Tech; 2017 Apr; 27(2):e12-e17. PubMed ID: 28234706
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective, multicenter, international phase 2 trial evaluating ultrasonic energy for pulmonary artery branch sealing in video-assisted thoracoscopic surgery lobectomy.
    Liberman M; Goudie E; Morse C; Hanna W; Evans N; Yasufuku K; Sampalis J;
    J Thorac Cardiovasc Surg; 2020 Jan; 159(1):301-311. PubMed ID: 31679701
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pilot study of pulmonary arterial branch sealing using energy devices in an ex vivo model.
    Liberman M; Khereba M; Goudie E; Kazakov J; Thiffault V; Lafontaine E; Ferraro P
    J Thorac Cardiovasc Surg; 2014 Dec; 148(6):3219-23. PubMed ID: 25125207
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.
    Landman J; Kerbl K; Rehman J; Andreoni C; Humphrey PA; Collyer W; Olweny E; Sundaram C; Clayman RV
    J Urol; 2003 Feb; 169(2):697-700. PubMed ID: 12544345
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safety of a thermal vessel sealer on main pulmonary vessels.
    Lacin T; Batirel HF; Ozer K; Demirutku A; Ahiskali R; Yuksel M
    Eur J Cardiothorac Surg; 2007 Mar; 31(3):482-5; discussion 485. PubMed ID: 17239609
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bipolar impedance-controlled sealing of the pulmonary artery with SealSafe G3 electric current: determination of bursting pressures in an ex vivo model.
    Kirschbaum A; Kunz J; Steinfeldt T; Pehl A; Meyer C; Bartsch DK
    J Surg Res; 2014 Dec; 192(2):611-5. PubMed ID: 25128924
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model.
    Hruby GW; Marruffo FC; Durak E; Collins SM; Pierorazio P; Humphrey PA; Mansukhani MM; Landman J
    J Urol; 2007 Dec; 178(6):2689-93. PubMed ID: 17945280
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implementation of a novel efficacy score to compare sealing and cutting devices in a porcine model.
    Brecht L; Wallwiener M; Schott S; Domschke C; Dinkic C; Golatta M; Schuetz F; Fluhr H; Stenzinger A; Kirchner M; Sohn C; Rom J
    Surg Endosc; 2018 Feb; 32(2):1002-1011. PubMed ID: 28840380
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intestinal Injury by Heat Conduction from Surgical Sealing Devices.
    Suzuki T; Hattori R; Minagawa T; Uehara T; Ogawa T; Ishizuka O
    JSLS; 2019; 23(1):. PubMed ID: 30846895
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of multiple use and sterilization on sealing performance of bipolar vessel sealing devices.
    Gardeweg S; Bockstahler B; Duprè G
    PLoS One; 2019; 14(8):e0221488. PubMed ID: 31430327
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.