These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 33156779)

  • 21. Chronic impedance spectroscopy of an endovascular stent-electrode array.
    Opie NL; John SE; Rind GS; Ronayne SM; Grayden DB; Burkitt AN; May CN; O'Brien TJ; Oxley TJ
    J Neural Eng; 2016 Aug; 13(4):046020. PubMed ID: 27378157
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Modification of a Ready-Made High-Voltage Pulse Generator for Non-Thermal Irreversible Electroporation.
    Zhang K; Wang J
    Bull Exp Biol Med; 2022 Jun; 173(2):276-280. PubMed ID: 35737162
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The Feasibility of a Smart Surgical Probe for Verification of IRE Treatments Using Electrical Impedance Spectroscopy.
    Bonakdar M; Latouche EL; Mahajan RL; Davalos RV
    IEEE Trans Biomed Eng; 2015 Nov; 62(11):2674-84. PubMed ID: 26057529
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Development of a Multi-Pulse Conductivity Model for Liver Tissue Treated With Pulsed Electric Fields.
    Zhao Y; Zheng S; Beitel-White N; Liu H; Yao C; Davalos RV
    Front Bioeng Biotechnol; 2020; 8():396. PubMed ID: 32509742
    [TBL] [Abstract][Full Text] [Related]  

  • 25. On-Chip Impedance Spectroscopy of Malaria-Infected Red Blood Cells.
    Panklang N; Techaumnat B; Tanthanuch N; Chotivanich K; Horprathum M; Nakano M
    Sensors (Basel); 2024 May; 24(10):. PubMed ID: 38794040
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Measurement and simulation of Joule heating during treatment of B-16 melanoma tumors in mice with nanosecond pulsed electric fields.
    Pliquett U; Nuccitelli R
    Bioelectrochemistry; 2014 Dec; 100():62-8. PubMed ID: 24680133
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cardiac impact of high-frequency irreversible electroporation using an asymmetrical waveform on liver in vivo.
    Li J; Wang J; Zhang X; Zhang X; Gao H; Xiao Y
    BMC Cardiovasc Disord; 2021 Dec; 21(1):581. PubMed ID: 34876030
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Voltage biasing, cyclic voltammetry, & electrical impedance spectroscopy for neural interfaces.
    Wilks SJ; Richner TJ; Brodnick SK; Kipke DR; Williams JC; Otto KJ
    J Vis Exp; 2012 Feb; (60):. PubMed ID: 22395095
    [TBL] [Abstract][Full Text] [Related]  

  • 29. High-Efficiency Single-Cell Electrical Impedance Spectroscopy.
    Feng Y; Huang L; Zhao P; Liang F; Wang W
    Methods Mol Biol; 2023; 2644():81-97. PubMed ID: 37142917
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electrical and thermal analyses of catheter-based irreversible electroporation of digestive tract.
    Ren F; Li Q; Gao X; Zhu K; Zhang J; Chen X; Yan X; Chu D; Hu L; Gao Z; Wu Z; Wu R; Lv Y
    Int J Hyperthermia; 2019; 36(1):854-867. PubMed ID: 31452435
    [No Abstract]   [Full Text] [Related]  

  • 31. Transient blood-brain barrier disruption is induced by low pulsed electrical fields in vitro: an analysis of permeability and trans-endothelial electric resistivity.
    Sharabi S; Bresler Y; Ravid O; Shemesh C; Atrakchi D; Schnaider-Beeri M; Gosselet F; Dehouck L; Last D; Guez D; Daniels D; Mardor Y; Cooper I
    Drug Deliv; 2019 Dec; 26(1):459-469. PubMed ID: 30957567
    [TBL] [Abstract][Full Text] [Related]  

  • 32. On-Chip Sinusoidal Signal Generators for Electrical Impedance Spectroscopy: Methodological Review.
    Kweon SJ; Rafi AK; Cheon SI; Je M; Ha S
    IEEE Trans Biomed Circuits Syst; 2022 Jun; 16(3):337-360. PubMed ID: 35482701
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Coronary Artery Disease and Inflammatory Activation Interfere with Peripheral Tissue Electrical Impedance Spectroscopy Characteristics-Initial Report.
    Urbanowicz T; Michalak M; Marzec E; Komosa A; Filipiak KJ; Olasińska-Wiśniewska A; Witkowska A; Rodzki M; Tykarski A; Jemielity M
    Int J Environ Res Public Health; 2023 Feb; 20(3):. PubMed ID: 36768108
    [TBL] [Abstract][Full Text] [Related]  

  • 34. New Microfluidic System for Electrochemical Impedance Spectroscopy Assessment of Cell Culture Performance: Design and Development of New Electrode Material.
    Chmayssem A; Tanase CE; Verplanck N; Gougis M; Mourier V; Zebda A; Ghaemmaghami AM; Mailley P
    Biosensors (Basel); 2022 Jun; 12(7):. PubMed ID: 35884254
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Wideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy.
    Valente V; Demosthenous A
    Sensors (Basel); 2016 Jul; 16(8):. PubMed ID: 27463721
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Predicting irreversible electroporation-induced tissue damage by means of magnetic resonance electrical impedance tomography.
    Kranjc M; Kranjc S; Bajd F; Serša G; Serša I; Miklavčič D
    Sci Rep; 2017 Sep; 7(1):10323. PubMed ID: 28871138
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Multi-parametric study of temperature and thermal damage of tumor exposed to high-frequency nanosecond-pulsed electric fields based on finite element simulation.
    Mi Y; Rui S; Li C; Yao C; Xu J; Bian C; Tang X
    Med Biol Eng Comput; 2017 Jul; 55(7):1109-1122. PubMed ID: 27853990
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Magnetic resonance electrical impedance tomography for measuring electrical conductivity during electroporation.
    Kranjc M; Bajd F; Serša I; Miklavčič D
    Physiol Meas; 2014 Jun; 35(6):985-96. PubMed ID: 24844299
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monitoring of Indoor Farming of Lettuce Leaves for 16 Hours Using Electrical Impedance Spectroscopy (EIS) and Double-Shell Model (DSM).
    Nouaze JC; Kim JH; Jeon GR; Kim JH
    Sensors (Basel); 2022 Dec; 22(24):. PubMed ID: 36560040
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Study of Real-Time Spatial and Temporal Behavior of Bacterial Biofilms Using 2-D Impedance Spectroscopy.
    Begly C; Ackart D; Mylius J; Basaraba R; Chicco AJ; Chen TW
    IEEE Trans Biomed Circuits Syst; 2020 Oct; 14(5):1051-1064. PubMed ID: 32746361
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.