These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 33161223)

  • 21. Bone ablation without thermal or acoustic mechanical injury via a novel picosecond infrared laser (PIRL).
    Jowett N; Wöllmer W; Reimer R; Zustin J; Schumacher U; Wiseman PW; Mlynarek AM; Böttcher A; Dalchow CV; Lörincz BB; Knecht R; Miller RJ
    Otolaryngol Head Neck Surg; 2014 Mar; 150(3):385-93. PubMed ID: 24376121
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Recrystallisation behaviour of a fully austenitic Nb-stabilised stainless steel.
    Barcellini C; Dumbill S; Jimenez-Melero E
    J Microsc; 2019 Apr; 274(1):3-12. PubMed ID: 30561019
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Characterization of dilute species within CVD-grown silicon nanowires doped using trimethylboron: protected lift-out specimen preparation for atom probe tomography.
    Prosa TJ; Alvis R; Tsakalakos L; Smentkowski VS
    J Microsc; 2010 Aug; 239(2):92-8. PubMed ID: 20629915
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Correlating Atom Probe Tomography with Atomic-Resolved Scanning Transmission Electron Microscopy: Example of Segregation at Silicon Grain Boundaries.
    Stoffers A; Barthel J; Liebscher CH; Gault B; Cojocaru-Mirédin O; Scheu C; Raabe D
    Microsc Microanal; 2017 Apr; 23(2):291-299. PubMed ID: 28215198
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Direct atomic-scale imaging of hydrogen and oxygen interstitials in pure niobium using atom-probe tomography and aberration-corrected scanning transmission electron microscopy.
    Kim YJ; Tao R; Klie RF; Seidman DN
    ACS Nano; 2013 Jan; 7(1):732-9. PubMed ID: 23259811
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Laser-assisted atom probe tomography of semiconductors: The impact of the focused-ion beam specimen preparation.
    Bogdanowicz J; Kumar A; Fleischmann C; Gilbert M; Houard J; Vella A; Vandervorst W
    Ultramicroscopy; 2018 May; 188():19-23. PubMed ID: 29529555
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Criteria and considerations for preparing atom-probe tomography specimens of nanomaterials utilizing an encapsulation methodology.
    Sun Z; Hazut O; Yerushalmi R; Lauhon LJ; Seidman DN
    Ultramicroscopy; 2018 Jan; 184(Pt A):225-233. PubMed ID: 28985626
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High speed direct imaging of thin metal film ablation by movie-mode dynamic transmission electron microscopy.
    Hihath S; Santala MK; Cen X; Campbell G; van Benthem K
    Sci Rep; 2016 Mar; 6():23046. PubMed ID: 26965073
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Study of recovery and first recrystallisation kinetics in CGO Fe3%Si steels using misorientation-derived parameters (EBSD).
    Cruz-Gandarilla F; Bolmaro RE; Mendoza-León HF; Salcedo-Garrido AM; Cabañas-Moreno JG
    J Microsc; 2019 Sep; 275(3):133-148. PubMed ID: 31271444
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Study of vertical Si/SiO2 interface using laser-assisted atom probe tomography and transmission electron microscopy.
    Lee JH; Lee BH; Kim YT; Kim JJ; Lee SY; Lee KP; Park CG
    Micron; 2014 Mar; 58():32-7. PubMed ID: 24411275
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The effect orientation of features in reconstructed atom probe data on the resolution and measured composition of T1 plates in an A2198 aluminium alloy.
    Mullin MA; Araullo-Peters VJ; Gault B; Cairney JM
    Ultramicroscopy; 2015 Dec; 159 Pt 2():368-73. PubMed ID: 25896290
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A guide on FIB preparation of samples containing stress corrosion crack tips for TEM and atom-probe analysis.
    Lozano-Perez S
    Micron; 2008; 39(3):320-8. PubMed ID: 18258443
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimal laser positioning for laser-assisted atom probe tomography.
    Koelling S; Innocenti N; Bogdanowicz J; Vandervorst W
    Ultramicroscopy; 2013 Sep; 132():70-4. PubMed ID: 23578966
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Investigations of field-evaporated end forms in voltage- and laser-pulsed atom probe tomography.
    Shariq A; Mutas S; Wedderhoff K; Klein C; Hortenbach H; Teichert S; Kücher P; Gerstl SS
    Ultramicroscopy; 2009 Apr; 109(5):472-9. PubMed ID: 19062187
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An in-situ approach for preparing atom probe tomography specimens by xenon plasma-focussed ion beam.
    Halpin JE; Webster RWH; Gardner H; Moody MP; Bagot PAJ; MacLaren DA
    Ultramicroscopy; 2019 Jul; 202():121-127. PubMed ID: 31005819
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Directed Atom-by-Atom Assembly of Dopants in Silicon.
    Hudak BM; Song J; Sims H; Troparevsky MC; Humble TS; Pantelides ST; Snijders PC; Lupini AR
    ACS Nano; 2018 Jun; 12(6):5873-5879. PubMed ID: 29750507
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Transmission electron microscopy and atom probe specimen preparation from mechanically alloyed powder using the focused ion-beam lift-out technique.
    Choi PP; Kwon YS; Kim JS; Al-Kassab T
    J Electron Microsc (Tokyo); 2007 Apr; 56(2):43-9. PubMed ID: 17928320
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Imaging of fullerene-like structures in CNx thin films by electron microscopy; sample preparation artefacts due to ion-beam milling.
    Czigány Z; Neidhardt J; Brunell IF; Hultman L
    Ultramicroscopy; 2003 Apr; 94(3-4):163-73. PubMed ID: 12524186
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Parallel preparation of plan-view transmission electron microscopy specimens by vapor-phase etching with integrated etch stops.
    English TS; Provine J; Marshall AF; Koh AL; Kenny TW
    Ultramicroscopy; 2016 Jul; 166():39-47. PubMed ID: 27160487
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Atom probe tomography and transmission electron microscopy characterisation of precipitation in an Al-Cu-Li-Mg-Ag alloy.
    Gault B; de Geuser F; Bourgeois L; Gabble BM; Ringer SP; Muddle BC
    Ultramicroscopy; 2011 May; 111(6):683-9. PubMed ID: 21239117
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.