240 related articles for article (PubMed ID: 33187889)
1. Comparison of the 22-gauge and 25-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration.
Sakaguchi T; Inoue T; Miyazawa T; Mineshita M
Respir Investig; 2021 Mar; 59(2):235-239. PubMed ID: 33187889
[TBL] [Abstract][Full Text] [Related]
2. Endobronchial Ultrasound Transbronchial Needle Aspiration With a 19-Gauge Needle vs 21- and 22-Gauge Needles for Mediastinal Lymphadenopathy.
Romatowski NPJ; Gillson AM; Stollery D; Dumoulin E; Vakil E; Dhaliwal I; MacEachern P; Hergott CA; Tyan CC; Mitchell M; Schieman C; Fortin M; Tremblay A
Chest; 2022 Sep; 162(3):712-720. PubMed ID: 35381259
[TBL] [Abstract][Full Text] [Related]
3. Comparison of 21-gauge and 22-gauge aspiration needle during endobronchial ultrasound-guided transbronchial needle aspiration.
Nakajima T; Yasufuku K; Takahashi R; Shingyoji M; Hirata T; Itami M; Matsui Y; Itakura M; Iizasa T; Kimura H
Respirology; 2011 Jan; 16(1):90-4. PubMed ID: 20920141
[TBL] [Abstract][Full Text] [Related]
4. Flexible 19-Gauge Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration Needle: First Experience.
Tyan C; Patel P; Czarnecka K; Gompelmann D; Eberhardt R; Fortin M; MacEachern P; Hergott CA; Dumoulin E; Tremblay A; Kemp SV; Shah PL; Herth FJF; Yasufuku K
Respiration; 2017; 94(1):52-57. PubMed ID: 28511175
[TBL] [Abstract][Full Text] [Related]
5. Comparison of two 22 G aspiration needles for histologic sampling during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA).
Izumo T; Sasada S; Watanabe J; Chavez C; Matsumoto Y; Tsuchida T
Jpn J Clin Oncol; 2014 Sep; 44(9):841-5. PubMed ID: 25057090
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the efficiency of endobronchial ultrasound-guided transbronchial needle aspiration using a 22G needle versus 25G needle for the diagnosis of lymph node metastasis in patients with lung cancer: a prospective randomized, crossover study.
Sakai T; Udagawa H; Kirita K; Nomura S; Itotani R; Tamiya Y; Sugimoto A; Ota T; Naito T; Izumi H; Nosaki K; Ikeda T; Zenke Y; Matsumoto S; Yoh K; Niho S; Nakai T; Ishii G; Goto K
Transl Lung Cancer Res; 2021 Sep; 10(9):3745-3758. PubMed ID: 34733625
[TBL] [Abstract][Full Text] [Related]
7. Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry.
Yarmus LB; Akulian J; Lechtzin N; Yasin F; Kamdar B; Ernst A; Ost DE; Ray C; Greenhill SR; Jimenez CA; Filner J; Feller-Kopman D;
Chest; 2013 Apr; 143(4):1036-1043. PubMed ID: 23632441
[TBL] [Abstract][Full Text] [Related]
8. Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration.
Di Felice C; Young B; Matta M
J Thorac Dis; 2019 Aug; 11(8):3643-3649. PubMed ID: 31559072
[TBL] [Abstract][Full Text] [Related]
9. Impact of needle gauge on characterization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) histology samples.
Jeyabalan A; Shelley-Fraser G; Medford AR
Respirology; 2014 Jul; 19(5):735-9. PubMed ID: 24697875
[TBL] [Abstract][Full Text] [Related]
10. Initial Polish experience of Flexible 19 gauge Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration.
Gnass M; Sola J; Filarecka A; Orzechowski S; Kocoń P; Pasieka-Lis M; Pankowski J; Rudnicka L; Soja J; Szlubowski A
Adv Respir Med; 2017; 85(2):64-68. PubMed ID: 28440531
[TBL] [Abstract][Full Text] [Related]
11. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.
Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH
BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845
[TBL] [Abstract][Full Text] [Related]
12. Endobronchial ultrasound in diagnosing and staging of lung cancer by Acquire 22G TBNB versus regular 22G TBNA needles: study protocol of a randomised clinical trial.
Kuijvenhoven JC; Kramer T; Korevaar DA; Ninaber MK; Trisolini R; Szlubowski A; Gnass M; von der Thüsen J; Cohen D; Bonta PI; Annema JT
BMJ Open; 2021 Sep; 11(9):e051820. PubMed ID: 34475187
[TBL] [Abstract][Full Text] [Related]
13. Comparison of endoscopic ultrasound-guided fine-needle aspiration and biopsy with 22-gauge and 25-gauge needles for the "precision medicine" of pancreatic cancer: A retrospective study.
Yoshizawa N; Yamada R; Sakuno T; Inoue H; Miura H; Takeuchi T; Nakamura M; Hamada Y; Katsurahara M; Tanaka K; Horiki N; Takei Y
Medicine (Baltimore); 2018 Jun; 97(24):e11096. PubMed ID: 29901627
[TBL] [Abstract][Full Text] [Related]
14. Prospective randomized trial to compare the safety, diagnostic yield and utility of 22-gauge and 19-gauge endobronchial ultrasound transbronchial needle aspirates and processing technique by cytology and histopathology.
Manley CJ; Kumar R; Gong Y; Huang M; Wei SS; Nagarathinam R; Haber A; Egleston B; Flieder D; Ehya H
J Am Soc Cytopathol; 2022; 11(2):114-121. PubMed ID: 34896033
[TBL] [Abstract][Full Text] [Related]
15. Initial experience with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) from a tuberculosis endemic population.
Madan K; Mohan A; Ayub II; Jain D; Hadda V; Khilnani GC; Guleria R
J Bronchology Interv Pulmonol; 2014 Jul; 21(3):208-14. PubMed ID: 24992128
[TBL] [Abstract][Full Text] [Related]
16. The diagnostic value of tissue button technique for specimen accusation during endobronchial ultrasound-guided transbronchial fine-needle aspiration.
Fruchter O; Breslavsky A; Brozgol T; Grossman A; Kessi M; Bugayov A; Shimelis K; Vaknine H; Sukmanov O
Clin Respir J; 2018 May; 12(5):1802-1808. PubMed ID: 29124891
[TBL] [Abstract][Full Text] [Related]
17. Impact of Endobronchial Ultrasound Guided Transbronchial Needle Aspiration on Diagnostic Yield of Bronchoscopy in Patients with Mediastinal Lymph Node Enlargement.
Osinka K; Zielińska-Krawczyk M; Korczyński P; Górnicka B; Krenke R
Adv Exp Med Biol; 2016; 911():33-43. PubMed ID: 26987324
[TBL] [Abstract][Full Text] [Related]
18. Comparing diagnostic sensitivity of different needle sizes for lymph nodes suspected of lung cancer in endobronchial ultrasound transbronchial needle aspiration: Systematic review and meta-analysis.
Yu Lee-Mateus A; Garcia-Saucedo JC; Abia-Trujillo D; Labarca G; Patel NM; Pascual JM; Fernandez-Bussy S
Clin Respir J; 2021 Dec; 15(12):1328-1336. PubMed ID: 34402194
[TBL] [Abstract][Full Text] [Related]
19. Endobronchial ultrasound-guided transbronchial needle aspiration in diagnosing intrathoracic tuberculosis.
Sun J; Teng J; Yang H; Li Z; Zhang J; Zhao H; Garfield DH; Han B
Ann Thorac Surg; 2013 Dec; 96(6):2021-7. PubMed ID: 24035300
[TBL] [Abstract][Full Text] [Related]
20. Conventional versus Ultrasound-Guided Transbronchial Needle Aspiration for the Diagnosis of Hilar/Mediastinal Lymph Adenopathies: A Randomized Controlled Trial.
Bonifazi M; Tramacere I; Zuccatosta L; Mei F; Sediari M; Paonessa MC; Gasparini S
Respiration; 2017; 94(2):216-223. PubMed ID: 28531883
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]