152 related articles for article (PubMed ID: 33202397)
1. A digital phoswich detector using time-over-threshold for depth of interaction in PET.
Prout DL; Gu Z; Shustef M; Chatziioannou AF
Phys Med Biol; 2020 Dec; 65(24):245017. PubMed ID: 33202397
[TBL] [Abstract][Full Text] [Related]
2. A CNN-based four-layer DOI encoding detector using LYSO and BGO scintillators for small animal PET imaging.
He W; Zhao Y; Zhao X; Huang W; Zhang L; Prout DL; Chatziioannou AF; Ren Q; Gu Z
Phys Med Biol; 2023 Apr; 68(9):. PubMed ID: 37040784
[No Abstract] [Full Text] [Related]
3. A DOI Detector With Crystal Scatter Identification Capability for High Sensitivity and High Spatial Resolution PET Imaging.
Gu Z; Prout DL; Silverman RW; Herman H; Dooraghi A; Chatziioannou AF
IEEE Trans Nucl Sci; 2015 Jun; 62(3):740-747. PubMed ID: 26478600
[TBL] [Abstract][Full Text] [Related]
4. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals.
Du J; AriƱo-Estrada G; Bai X; Cherry SR
Phys Med Biol; 2020 Nov; 65(23):. PubMed ID: 33086214
[TBL] [Abstract][Full Text] [Related]
5. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
[TBL] [Abstract][Full Text] [Related]
6. Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs.
Binder T; Kang HG; Nitta M; Schneider F; Yamaya T; Parodi K; Wiest F; Thirolf PG
Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 33906179
[TBL] [Abstract][Full Text] [Related]
7. A multi-resolution TOF-DOI detector for human brain dedicated PET scanner.
He W; Zhao Y; Huang W; Zhao X; Niu M; Yang H; Zhang L; Ren Q; Gu Z
Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38181423
[No Abstract] [Full Text] [Related]
8. Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector.
Chang CM; Cates JW; Levin CS
Phys Med Biol; 2017 Jan; 62(1):258-271. PubMed ID: 27991437
[TBL] [Abstract][Full Text] [Related]
9. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction.
Yi M; Ko GB; Lee JS
Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38091614
[No Abstract] [Full Text] [Related]
10. Characterization of three layer depth of interaction PET detectors for small animal imaging.
Behnamian H; Shafiee M
Biomed Phys Eng Express; 2018 Aug; 4(5):. PubMed ID: 34253005
[TBL] [Abstract][Full Text] [Related]
11. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
Zhang Y; Yan H; Baghaei H; Wong WH
Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144
[TBL] [Abstract][Full Text] [Related]
12. Performance of long rectangular semi-monolithic scintillator PET detectors.
Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
[TBL] [Abstract][Full Text] [Related]
13. Edge effect reduction of high-resolution PET detectors using LYSO and GAGG phoswich crystals.
Liu Z; Mungai S; Niu M; Kuang Z; Ren N; Wang X; Sang Z; Yang Y
Phys Med Biol; 2023 Mar; 68(6):. PubMed ID: 36808920
[No Abstract] [Full Text] [Related]
14. An edge-readout, multilayer detector for positron emission tomography.
Li X; Ruiz-Gonzalez M; Furenlid LR
Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
[TBL] [Abstract][Full Text] [Related]
15. Simulation study of potential time-of-flight capabilities for a multilayer DOI-PET detector with an independent readout structure.
Watanabe M; Moriya T; Uchida H; Omura T
Phys Med Biol; 2021 Sep; 66(18):. PubMed ID: 34293731
[TBL] [Abstract][Full Text] [Related]
16. Performance evaluation of HiPET, a high sensitivity and high resolution preclinical PET tomograph.
Gu Z; Taschereau R; Vu NT; Prout DL; Lee J; Chatziioannou AF
Phys Med Biol; 2020 Feb; 65(4):045009. PubMed ID: 31935693
[TBL] [Abstract][Full Text] [Related]
17. Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals.
Cucarella N; Barrio J; Lamprou E; Valladares C; Benlloch JM; Gonzalez AJ
Med Phys; 2021 Dec; 48(12):8010-8023. PubMed ID: 34723380
[TBL] [Abstract][Full Text] [Related]
18. Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept.
Turtos RM; Gundacker S; Auffray E; Lecoq P
Phys Med Biol; 2019 Sep; 64(18):185018. PubMed ID: 30978716
[TBL] [Abstract][Full Text] [Related]
19. BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.
Brunner SE; Schaart DR
Phys Med Biol; 2017 Jun; 62(11):4421-4439. PubMed ID: 28358722
[TBL] [Abstract][Full Text] [Related]
20. A thick semi-monolithic scintillator detector for clinical PET scanners.
Zhang C; Wang X; Sun M; Kuang Z; Zhang X; Ren N; Wu S; Sang Z; Sun T; Hu Z; Yang Y; Liu Z
Phys Med Biol; 2021 Mar; 66(6):065023. PubMed ID: 33709958
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]