BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 33203254)

  • 1. Comparison of Short-Term Radiographical and Clinical Outcomes After Posterior Lumbar Interbody Fusion With a 3D Porous Titanium Alloy Cage and a Titanium-Coated PEEK Cage.
    Makino T; Takenaka S; Sakai Y; Yoshikawa H; Kaito T
    Global Spine J; 2022 Jun; 12(5):931-939. PubMed ID: 33203254
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of mechanical stability on the progress of bone ongrowth on the frame surfaces of a titanium-coated PEEK cage and a 3D porous titanium alloy cage: in vivo analysis using CT color mapping.
    Makino T; Takaneka S; Sakai Y; Yoshikawa H; Kaito T
    Eur Spine J; 2021 May; 30(5):1303-1313. PubMed ID: 33389201
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Application of three-dimensional printed porous titanium alloy cage and poly-ether-ether-ketone cage in posterior lumbar interbody fusion].
    Wang Y; Zhou Y; Chai X; Zhuo H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Sep; 36(9):1126-1131. PubMed ID: 36111476
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Fusion, Subsidence, and Clinical Results Between 3D-Printed Porous Titanium Cage and Polyetheretherketone Cage in Posterior Lumbar Interbody Fusion: A Minimum of 2 Years Follow-Up.
    Yang JJ; Kim DM; Park S
    World Neurosurg; 2023 Jul; ():. PubMed ID: 37419312
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surgical outcomes after posterior lumbar interbody fusion using traditional trajectory screw fixation or cortical bone trajectory screw fixation: A comparative study between the polyetheretherketone cage and the same shape titanium-coated polyetheretherketone cage.
    Sakaura H; Ikegami D; Fujimori T; Sugiura T; Yamada S; Mukai Y
    Clin Neurol Neurosurg; 2021 Oct; 209():106945. PubMed ID: 34555798
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage.
    Segi N; Nakashima H; Shinjo R; Kagami Y; Machino M; Ito S; Ouchida J; Morishita K; Oishi R; Yamauchi I; Imagama S
    Medicina (Kaunas); 2023 Feb; 59(2):. PubMed ID: 36837573
    [No Abstract]   [Full Text] [Related]  

  • 7. Early Fusion Status After Posterior Lumbar Interbody Fusion With Cortical Bone Trajectory Screw Fixation or Traditional Trajectory Screw Fixation: A Comparison Between the Titanium-coated Polyetheretherketone Cage and the Same Shape Polyetheretherketone Cage.
    Sakaura H; Ikegami D; Fujimori T; Sugiura T; Mukai Y
    Clin Spine Surg; 2022 Feb; 35(1):E47-E52. PubMed ID: 34369910
    [TBL] [Abstract][Full Text] [Related]  

  • 8. PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence.
    Campbell PG; Cavanaugh DA; Nunley P; Utter PA; Kerr E; Wadhwa R; Stone M
    Neurosurg Focus; 2020 Sep; 49(3):E10. PubMed ID: 32871573
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Titanium-coated PEEK Cage Maintains Better Bone Fusion With the Endplate Than the PEEK Cage 6 Months After PLIF Surgery: A Multicenter, Prospective, Randomized Study.
    Hasegawa T; Ushirozako H; Shigeto E; Ohba T; Oba H; Mukaiyama K; Shimizu S; Yamato Y; Ide K; Shibata Y; Ojima T; Takahashi J; Haro H; Matsuyama Y
    Spine (Phila Pa 1976); 2020 Aug; 45(15):E892-E902. PubMed ID: 32675599
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early Fusion Status after Posterior Lumbar Interbody Fusion with Cortical Bone Trajectory Screw Fixation: A Comparison of Titanium-Coated Polyetheretherketone Cages and Carbon Polyetheretherketone Cages.
    Sakaura H; Ohnishi A; Yamagishi A; Ohwada T
    Asian Spine J; 2019 Apr; 13(2):248-253. PubMed ID: 30481976
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison in the same intervertebral space between titanium-coated and uncoated PEEK cages in lumbar interbody fusion surgery.
    Kashii M; Kitaguchi K; Makino T; Kaito T
    J Orthop Sci; 2020 Jul; 25(4):565-570. PubMed ID: 31375363
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiological Outcomes of Posterior Lumbar Interbody Fusion Using a Titanium-coated PEEK Cage.
    Manabe H; Sakai T; Morimoto M; Tezuka F; Yamashita K; Takata Y; Sairyo K
    J Med Invest; 2019; 66(1.2):119-122. PubMed ID: 31064922
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model.
    McGilvray KC; Easley J; Seim HB; Regan D; Berven SH; Hsu WK; Mroz TE; Puttlitz CM
    Spine J; 2018 Jul; 18(7):1250-1260. PubMed ID: 29496624
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of sufficient contact between the autograft and endplate soon after surgery to prevent nonunion at 12 months following posterior lumbar interbody fusion.
    Ushirozako H; Hasegawa T; Ebata S; Ohba T; Oba H; Mukaiyama K; Shimizu S; Yamato Y; Ide K; Shibata Y; Ojima T; Takahashi J; Haro H; Matsuyama Y
    J Neurosurg Spine; 2020 Aug; 33(6):796-805. PubMed ID: 32764175
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early bone ingrowth and segmental stability of a trussed titanium cage versus a polyether ether ketone cage in an ovine lumbar interbody fusion model.
    Loenen ACY; Peters MJM; Bevers RTJ; Schaffrath C; van Haver E; Cuijpers VMJI; Rademakers T; van Rietbergen B; Willems PC; Arts JJ
    Spine J; 2022 Jan; 22(1):174-182. PubMed ID: 34274502
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage.
    Adl Amini D; Okano I; Oezel L; Zhu J; Chiapparelli E; Shue J; Sama AA; Cammisa FP; Girardi FP; Hughes AP
    Eur Spine J; 2021 Aug; 30(8):2377-2384. PubMed ID: 34215921
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Vertebral Endplate Cyst as a Predictor of Nonunion After Lumbar Interbody Fusion: Comparison of Titanium and Polyetheretherketone Cages.
    Tanida S; Fujibayashi S; Otsuki B; Masamoto K; Takahashi Y; Nakayama T; Matsuda S
    Spine (Phila Pa 1976); 2016 Oct; 41(20):E1216-E1222. PubMed ID: 27054449
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Polyetheretherketone Versus Titanium Cages for Posterior Lumbar Interbody Fusion: Meta-Analysis and Review of the Literature.
    Massaad E; Fatima N; Kiapour A; Hadzipasic M; Shankar GM; Shin JH
    Neurospine; 2020 Mar; 17(1):125-135. PubMed ID: 32252163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiological comparison of instrumented posterior lumbar interbody fusion with one or two closed-box plasmapore coated titanium cages: follow-up study over more than seven years.
    Kroppenstedt S; Gulde M; Schönmayr R
    Spine (Phila Pa 1976); 2008 Sep; 33(19):2083-8. PubMed ID: 18758364
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cage subsidence in lateral interbody fusion with transpsoas approach: intraoperative endplate injury or late-onset settling.
    Satake K; Kanemura T; Nakashima H; Yamaguchi H; Segi N; Ouchida J
    Spine Surg Relat Res; 2017; 1(4):203-210. PubMed ID: 31440635
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.