These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 33206662)

  • 1. Optimal coordinated control of hybrid AC/VSC-HVDC system integrated with DFIG via cooperative beetle antennae search algorithm.
    Hao J; Huang J; Zhang A; Ai H; Zhang Q; Yang B
    PLoS One; 2020; 15(11):e0242316. PubMed ID: 33206662
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correction: Optimal coordinated control of hybrid AC/VSC-HVDC system integrated with DFIG via cooperative beetle antennae search algorithm.
    PLOS ONE staff
    PLoS One; 2020; 15(12):e0244757. PubMed ID: 33362270
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Coordinate Fault Ride-Through Strategy for Connection of Offshore Wind Farms Using Voltage Source-Converter-Based High-Voltage Direct-Current Transmission under Single Polar Fault.
    Zhou H; Ge S; Qin L
    Sensors (Basel); 2023 Jun; 23(12):. PubMed ID: 37420925
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Inertial imitation method of MMC with hybrid topology for VSC-HVDC.
    Wu J; Yin S; Li C; Zhang Q
    PLoS One; 2022; 17(12):e0277553. PubMed ID: 36490297
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Adaptive Modulation for DFIG and STATCOM With High-Voltage Direct Current Transmission.
    Tang Y; He H; Ni Z; Wen J; Huang T
    IEEE Trans Neural Netw Learn Syst; 2016 Aug; 27(8):1762-72. PubMed ID: 26701900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance analysis of DFIG support microgrid using GA optimized restricted Boltzmann Machine algorithm.
    Bhol R; Swain SC; Dash R; Jyotheeswara Reddy K; Dhanamjayulu C; Kotb H; Emara A
    Heliyon; 2024 May; 10(10):e30669. PubMed ID: 38770320
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nonlinear control of voltage source converters in AC-DC power system.
    Dash PK; Nayak N
    ISA Trans; 2014 Jul; 53(4):1268-85. PubMed ID: 24906895
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Enhanced beetle antennae search algorithm for complex and unbiased optimization.
    Qian Q; Deng Y; Sun H; Pan J; Yin J; Feng Y; Fu Y; Li Y
    Soft comput; 2022; 26(19):10331-10369. PubMed ID: 36034767
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling of Efficient Control Strategies for LCC-HVDC Systems: A Case Study of Matiari-Lahore HVDC Power Transmission Line.
    Ahmed A; Khan D; Khan AM; Mustafa MU; Panjwani MK; Hanan M; Agyekum EB; Uhunamure SE; Edokpayi JN
    Sensors (Basel); 2022 Apr; 22(7):. PubMed ID: 35408407
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of short-duration voltage variations on VSC-HVDC performance.
    Mostafa RA; Emary A; Sayed A; El-Shimy M
    Sci Rep; 2023 Dec; 13(1):23055. PubMed ID: 38155218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Application of Auto-Disturbance Rejection Control Optimized by Least Squares Support Vector Machines Method and Time-Frequency Representation in Voltage Source Converter-High Voltage Direct Current System.
    Liu YP; Liang HP; Gao ZK
    PLoS One; 2015; 10(6):e0130135. PubMed ID: 26098556
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimal coordinated voltage control in active distribution networks using backtracking search algorithm.
    Tengku Hashim TJ; Mohamed A
    PLoS One; 2017; 12(10):e0177507. PubMed ID: 28991919
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal low voltage ride through of wind turbine doubly fed induction generator based on bonobo optimization algorithm.
    Mostafa MA; El-Hay EA; Elkholy MM
    Sci Rep; 2023 May; 13(1):7778. PubMed ID: 37179378
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PSO-Based Smart Grid Application for Sizing and Optimization of Hybrid Renewable Energy Systems.
    Mohamed MA; Eltamaly AM; Alolah AI
    PLoS One; 2016; 11(8):e0159702. PubMed ID: 27513000
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A decoupled circuital model methodology for calculating DC currents in AC grids induced by HVDC grounding current.
    Zhu L; Fu C; Liu H; Zhao D; Su L; Rehman H; Ji S
    PLoS One; 2019; 14(1):e0209548. PubMed ID: 30629629
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Control Strategy for Ground Fault on the AC Side of MMC-HVDC System.
    Li H; Guo L
    Comput Intell Neurosci; 2022; 2022():1776209. PubMed ID: 36203730
    [TBL] [Abstract][Full Text] [Related]  

  • 17. LVRT capability enhancement of DFIG based wind turbine with coordination control of dynamic voltage restorer and inductive fault current limiter.
    Zhang D; Xu H; Qiao L; Chen L
    PLoS One; 2019; 14(8):e0221410. PubMed ID: 31454380
    [TBL] [Abstract][Full Text] [Related]  

  • 18. PSO-GSA based fuzzy sliding mode controller for DFIG-based wind turbine.
    Bounar N; Labdai S; Boulkroune A
    ISA Trans; 2019 Feb; 85():177-188. PubMed ID: 30389242
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fault ride-through enhancement using an enhanced field oriented control technique for converters of grid connected DFIG and STATCOM for different types of faults.
    Ananth DV; Nagesh Kumar GV
    ISA Trans; 2016 May; 62():2-18. PubMed ID: 25840675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Novel Ensemble Fault Diagnosis Model for Main Circulation Pumps of Converter Valves in VSC-HVDC Transmission Systems.
    Zhou S; Qin L; Yang Y; Wei Z; Wang J; Wang J; Ruan J; Tang X; Wang X; Liu K
    Sensors (Basel); 2023 May; 23(11):. PubMed ID: 37299809
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.