These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 33208048)

  • 1. Simulation study on modified coil configuration used for shrink fitting of semi-built-up crankshaft and parameters influencing the thermal distribution.
    Duan J; Zhang Q; Long X; Zhang K
    Sci Prog; 2020; 103(4):36850420967858. PubMed ID: 33208048
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The analysis of shrink-fit connection - the methods of heating and the factors influencing the distribution of residual stresses.
    Król R; Siemiątkowski Z
    Heliyon; 2019 Nov; 5(11):e02839. PubMed ID: 31844741
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Numerical Study of Ti6Al4V Alloy Tube Heated by Super-Frequency Induction Heating.
    Liu C; Han J; Lu R; Liu J; Ma X
    Materials (Basel); 2023 May; 16(11):. PubMed ID: 37297074
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element analysis of the temperature distribution within a Conduction-Cooled, MgB
    Zhang D; Sumption MD; Majoros M; Collings EW; Panik D; Rindfleisch M; Doll D; Tomsic MJ
    Cryogenics (Guildf); 2022 Oct; 127():. PubMed ID: 37842207
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modeling of Eddy Current Welding of Rail: Three-Dimensional Simulation.
    Sun X; Liu H; Song W; Villecco F
    Entropy (Basel); 2020 Aug; 22(9):. PubMed ID: 33286716
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and Assessment of a Novel Biconical Human-Sized Alternating Magnetic Field Coil for MNP Hyperthermia Treatment of Deep-Seated Cancer.
    Shoshiashvili L; Shamatava I; Kakulia D; Shubitidze F
    Cancers (Basel); 2023 Mar; 15(6):. PubMed ID: 36980560
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of a dispersive ground electrode with a loosely wound helical coil for interstitial radiofrequency thermal therapy.
    McCann C; Sherar MD
    Phys Med Biol; 2006 Aug; 51(15):3851-63. PubMed ID: 16861785
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Simplified Calculation Method of Heat Source Model for Induction Heating.
    Dong H; Zhao Y; Yuan H; Hu X; Yang Z
    Materials (Basel); 2019 Sep; 12(18):. PubMed ID: 31514345
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite Element Analysis of Extrusion Process for Magnesium Alloy Internal Threads with Electromagnetic Induction-Assisted Heating and Thread Performance Research.
    Liu M; Ji Z; Fan R; Wang X
    Materials (Basel); 2020 May; 13(9):. PubMed ID: 32397214
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization Design of Quenching and Tempering Parameters for Crankshaft Based on Response Surface Methodology.
    Wang Y; Tang J; Chen J; Nie Z; Zhao D
    Materials (Basel); 2024 Jul; 17(15):. PubMed ID: 39124307
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative analysis for the effect of the thermal physical property parameter of adhesive on the thermal performance of the quadrupolar fiber coil.
    Zhang Z; Yu F
    Opt Express; 2017 Nov; 25(24):30513-30525. PubMed ID: 29221079
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fast computation of soft tissue thermal response under deformation based on fast explicit dynamics finite element algorithm for surgical simulation.
    Zhang J; Chauhan S
    Comput Methods Programs Biomed; 2020 Apr; 187():105244. PubMed ID: 31805458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of Coil Configurations for a Contactless Thermal Tumor Ablation With Implanted Devices.
    Prantner M; Parspour N; Haen SP; Bockeler M; Hetzel J
    IEEE Trans Biomed Circuits Syst; 2022 Feb; 16(1):79-93. PubMed ID: 35025749
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Practical induction heating coil designs for clinical hyperthermia with ferromagnetic implants.
    Stauffer PR; Sneed PK; Hashemi H; Phillips TL
    IEEE Trans Biomed Eng; 1994 Jan; 41(1):17-28. PubMed ID: 8200664
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thermal heating of human tissue induced by electromagnetic fields of magnetic resonance imaging.
    Thiele JP; Golombeck MA; Dössel O
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():743-6. PubMed ID: 12465291
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transient Thermal Response of a Guarded-Hot-Plate Apparatus for Operation Over an Extended Temperature Range.
    Thomas WC; Zarr RR
    J Res Natl Inst Stand Technol; 2018; 123():1-24. PubMed ID: 34877128
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Simulation Model for the Inductor of Electromagnetic Levitation Melting and Its Validation.
    Nycz B; Przyłucki R; Maliński Ł; Golak S
    Materials (Basel); 2023 Jun; 16(13):. PubMed ID: 37444947
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Temperature-controlled power modulation compensates for heterogeneous nanoparticle distributions: a computational optimization analysis for magnetic hyperthermia.
    Kandala SK; Liapi E; Whitcomb LL; Attaluri A; Ivkov R
    Int J Hyperthermia; 2019; 36(1):115-129. PubMed ID: 30541354
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Numerical Simulation of Tube Manufacturing Consisting of Roll Forming and High-Frequency Induction Welding.
    Egger C; Lüchinger M; Schreiner M; Tillmann W
    Materials (Basel); 2022 Feb; 15(3):. PubMed ID: 35161214
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.