202 related articles for article (PubMed ID: 33216254)
1. Outcomes of concomitant mesh placement and intestinal procedures during open ventral hernia repair.
Moazzez A; Dubina ED; Park H; Shover AL; Kim DY; de Virgilio CM
Hernia; 2021 Jun; 25(3):701-708. PubMed ID: 33216254
[TBL] [Abstract][Full Text] [Related]
2. Outcomes of light and midweight synthetic mesh use in clean-contaminated and contaminated ventral incisional hernia repair: an ACHQC comparative analysis.
Polcz ME; Pierce RA; Olson MA; Blankush J; Duke MC; Broucek J; Bradley JF
Surg Endosc; 2023 Jul; 37(7):5583-5590. PubMed ID: 36319897
[TBL] [Abstract][Full Text] [Related]
3. Comparative analysis of biologic versus synthetic mesh outcomes in contaminated hernia repairs.
Majumder A; Winder JS; Wen Y; Pauli EM; Belyansky I; Novitsky YW
Surgery; 2016 Oct; 160(4):828-838. PubMed ID: 27452954
[TBL] [Abstract][Full Text] [Related]
4. Ventral hernia repair using bioresorbable poly-4-hydroxybutyrate mesh in clean and contaminated surgical fields: a systematic review and meta-analysis.
Ahmed A; Gandhi S; Ganam S; Diab AF; Mhaskar R; Sujka J; DuCoin C; Docimo S
Hernia; 2024 Apr; 28(2):575-584. PubMed ID: 38345668
[TBL] [Abstract][Full Text] [Related]
5. A dual-stage approach to contaminated, high-risk ventral hernia repairs.
Kugler NW; Bobbs M; Webb T; Carver TW; Milia D; Paul JS
J Surg Res; 2016 Jul; 204(1):200-4. PubMed ID: 27451887
[TBL] [Abstract][Full Text] [Related]
6. Outcomes with porcine acellular dermal matrix versus synthetic mesh and suture in complicated open ventral hernia repair.
Liang MK; Berger RL; Nguyen MT; Hicks SC; Li LT; Leong M
Surg Infect (Larchmt); 2014 Oct; 15(5):506-12. PubMed ID: 25215466
[TBL] [Abstract][Full Text] [Related]
7. Use of mesh during ventral hernia repair in clean-contaminated and contaminated cases: outcomes of 33,832 cases.
Choi JJ; Palaniappa NC; Dallas KB; Rudich TB; Colon MJ; Divino CM
Ann Surg; 2012 Jan; 255(1):176-80. PubMed ID: 21677561
[TBL] [Abstract][Full Text] [Related]
8. Early Wound Morbidity after Open Ventral Hernia Repair with Biosynthetic or Polypropylene Mesh.
Sahoo S; Haskins IN; Huang LC; Krpata DM; Derwin KA; Poulose BK; Rosen MJ
J Am Coll Surg; 2017 Oct; 225(4):472-480.e1. PubMed ID: 28826804
[TBL] [Abstract][Full Text] [Related]
9. Predictors for surgical site infection in patients undergoing therapeutic or prophylactic intra-abdominal onlay mesh (IPOM) implantation in clean and contaminated surgical fields.
Jakob MO; Brüggemann A; Moser N; Candinas D; Beldi G; Haltmeier T
Surg Endosc; 2023 Sep; 37(9):6885-6894. PubMed ID: 37311892
[TBL] [Abstract][Full Text] [Related]
10. Laparoscopic ventral hernia repair with primary fascial closure versus bridged repair: a risk-adjusted comparative study.
Wennergren JE; Askenasy EP; Greenberg JA; Holihan J; Keith J; Liang MK; Martindale RG; Trott S; Plymale M; Roth JS
Surg Endosc; 2016 Aug; 30(8):3231-8. PubMed ID: 26578434
[TBL] [Abstract][Full Text] [Related]
11. Non-coated versus coated mesh for retrorectus ventral hernia repair: a propensity score-matched analysis of the Americas Hernia Society Quality Collaborative (AHSQC).
Thomas JD; Fafaj A; Zolin SJ; Horne CM; Huang LC; Phillips S; Rosenblatt S; Petro CC; Krpata DM; Rosen MJ; Prabhu AS
Hernia; 2021 Jun; 25(3):665-672. PubMed ID: 32495048
[TBL] [Abstract][Full Text] [Related]
12. Absorbable mesh in a contaminated field: hernia repair outcomes.
Wagner V; Levy BE; Castle JT; Plymale M; Roth JS; Totten C
Updates Surg; 2023 Aug; 75(5):1337-1342. PubMed ID: 36459367
[TBL] [Abstract][Full Text] [Related]
13. Suture, synthetic, or biologic in contaminated ventral hernia repair.
Bondre IL; Holihan JL; Askenasy EP; Greenberg JA; Keith JN; Martindale RG; Roth JS; Liang MK;
J Surg Res; 2016 Feb; 200(2):488-94. PubMed ID: 26424112
[TBL] [Abstract][Full Text] [Related]
14. The Use of Mesh in Emergent Ventral Hernia Repair: Effects on Early Patient Morbidity and Mortality.
Haskins IN; Amdur RL; Lin PP; Vaziri K
J Gastrointest Surg; 2016 Nov; 20(11):1899-1903. PubMed ID: 27456013
[TBL] [Abstract][Full Text] [Related]
15. History of methicillin-resistant Staphylococcus aureus (MRSA) surgical site infection may not be a contraindication to ventral hernia repair with synthetic mesh: a preliminary report.
Hicks CW; Blatnik JA; Krpata DM; Novitsky YW; Rosen MJ
Hernia; 2014 Feb; 18(1):65-70. PubMed ID: 23329253
[TBL] [Abstract][Full Text] [Related]
16. Robotic approach for retromuscular ventral hernia repair may be associated with improved wound morbidity in high-risk patients: a propensity score analysis.
Gaskins J; Huang LC; McPhail L; O'Connor S
Surg Endosc; 2024 Feb; 38(2):1013-1019. PubMed ID: 38091108
[TBL] [Abstract][Full Text] [Related]
17. Mesh Type With Ventral Hernia Repair: A Systematic Review and Meta-analysis of Randomized Trials.
Siddiqui A; Lyons NB; Anwoju O; Cohen BL; Ramsey WA; O'Neil CF; Ali Z; Liang MK
J Surg Res; 2023 Nov; 291():603-610. PubMed ID: 37542774
[TBL] [Abstract][Full Text] [Related]
18. The safety and efficacy of prosthetic hernia repair in clean-contaminated and contaminated wounds.
Kelly ME; Behrman SW
Am Surg; 2002 Jun; 68(6):524-8; discussion 528-9. PubMed ID: 12079133
[TBL] [Abstract][Full Text] [Related]
19. Large Contaminated Ventral Hernia Repair Using Component Separation Technique with Synthetic Mesh.
Slater NJ; Knaapen L; Bökkerink WJV; Biemans MJA; Buyne OR; Ulrich DJO; Bleichrodt RP; van Goor H
Plast Reconstr Surg; 2015 Dec; 136(6):796e-805e. PubMed ID: 26595034
[TBL] [Abstract][Full Text] [Related]
20. No-Touch Technique of Mesh Placement in Ventral Hernia Repair: Minimizing Postoperative Mesh Infections.
Schneeberger SJ; Kraft CT; Janis JE
Plast Reconstr Surg; 2020 May; 145(5):1288-1291. PubMed ID: 32332554
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]