These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

69 related articles for article (PubMed ID: 3323352)

  • 1. Influence of the haemodynamic parameters on the repartition of the flow between an artery and its graft.
    Rieu R; Bano S; Pelissier R; Bergeron P; Reggi M; Courbier R
    Int Angiol; 1987; 6(2):147-52. PubMed ID: 3323352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Factors determining late patency of aortobifemoral bypass graft].
    Davidović LB; Lotina SI; Kostić DM; Cinara II; Cvetković SD; Stojanov PL; Velimirović DB; Marković MM; Pejkić SA; Vukotić AM
    Srp Arh Celok Lek; 1997; 125(1-2):24-35. PubMed ID: 17974352
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Physical and physiological principles of calculating vascular resistance in cardiovascular circulation].
    Hennig E
    Vasa Suppl; 1992; 36():6-13. PubMed ID: 1529426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Numerical investigation of blood flow in the distal end of an axis-deviated arterial bypass model.
    Sun A; Fan Y; Deng X
    Biorheology; 2009; 46(2):83-92. PubMed ID: 19458412
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The value of ultrasound Doppler pulse curve parameters in the assessment of stenotic arterial diseases].
    Scharf R; Cobet U; Millner R
    Ultraschall Med; 1988 Apr; 9(2):67-71. PubMed ID: 3041585
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influences of stenosis on the downstream flow pattern in curved arteries.
    Liu B
    Med Eng Phys; 2007 Oct; 29(8):868-76. PubMed ID: 17081795
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the hemodynamics in 6mm and 4-7 mm hemodialysis grafts by means of CFD.
    Van Tricht I; De Wachter D; Tordoir J; Verdonck P
    J Biomech; 2006; 39(2):226-36. PubMed ID: 16321624
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of the simplified Bernoulli relationship in measuring pressure gradients across stenosis.
    Rieu R; Pelissier R; Isaaz K
    Int Angiol; 1989; 8(4):210-5. PubMed ID: 2699483
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wave propagation in a model of the arterial circulation.
    Wang JJ; Parker KH
    J Biomech; 2004 Apr; 37(4):457-70. PubMed ID: 14996557
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The area of the pressure-flow loop for assessment of arterial stenosis: a new index.
    Ovadia-Blechman Z; Einav S; Zaretsky U; Castel D; Toledo E; Eldar M
    Technol Health Care; 2002; 10(1):39-56. PubMed ID: 11847447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemodynamics of critical arterial stenoses.
    Belcaro G; Possati F; Sager P; Rosenkvist L
    Acta Chir Belg; 1983; 83(1):12-9. PubMed ID: 6858522
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A mathematical model for blood flow through an arterial bifurcation.
    Tandon PN; Kawahara M; Rana UV
    Int J Biomed Comput; 1994 May; 35(4):309-25. PubMed ID: 8063457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Influences of graft diameter on the blood flow in 2-way bypassing surgery].
    Qiao A; Liu Y; Zhang S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):346-50, 377. PubMed ID: 18610620
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The vascular steal phenomenon: an experimental model.
    Billet A; Queral LA; Polito WF; Dagher FJ
    Surgery; 1984 Nov; 96(5):923-8. PubMed ID: 6495180
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Geometric design improvements for femoral graft-artery junctions mitigating restenosis.
    Lei M; Kleinstreuer C; Archie JP
    J Biomech; 1996 Dec; 29(12):1605-14. PubMed ID: 8945659
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mathematical modeling of arterial blood flow and correlation to atherosclerosis.
    Perktold K; Rappitsch G
    Technol Health Care; 1995 Dec; 3(3):139-51. PubMed ID: 8749862
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The predictive value of arterial renal blood flow parameters in renal graft survival.
    Łebkowska U; Malyszko J; Łebkowski W; Brzósko S; Kowalewski R; Łebkowski T; Janica J; Michalak P; Gacko M; Myśliwiec M; Walecki J
    Transplant Proc; 2007 Nov; 39(9):2727-9. PubMed ID: 18021970
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of tapered grafts on hemodynamics and flow rate in dialysis access grafts.
    Krueger U; Huhle A; Krys K; Scholz H
    Artif Organs; 2004 Jul; 28(7):623-8. PubMed ID: 15209854
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Medical application oriented blood flow simulation.
    Qiao A; Liu Y
    Clin Biomech (Bristol, Avon); 2008; 23 Suppl 1():S130-6. PubMed ID: 18023946
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraoperative iliac artery stents: combination with infra-inguinal revascularization procedures.
    Demasi RJ; Snyder SO; Wheeler JR; Gregory RT; Gayle RG; Parent FN; Gandhi RH
    Am Surg; 1994 Nov; 60(11):854-9. PubMed ID: 7978681
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.