These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

347 related articles for article (PubMed ID: 33237494)

  • 1. The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis.
    Pecoraro V; Petri D; Costantino G; Squizzato A; Moja L; Virgili G; Lucenteforte E
    Intern Emerg Med; 2021 Jun; 16(4):1071-1083. PubMed ID: 33237494
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-contact infrared thermometers compared with current approaches in primary care for children aged 5 years and under: a method comparison study.
    Van den Bruel A; Verbakel J; Wang K; Fleming S; Holtman G; Glogowska M; Morris E; Edwards G; Abakar Ismail F; Curtis K; Goetz J; Barnes G; Slivkova R; Nesbitt C; Aslam S; Swift E; Williams H; Hayward G
    Health Technol Assess; 2020 Oct; 24(53):1-28. PubMed ID: 33111663
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Infrared tympanic thermometry compared to mercury thermometers].
    Valle PC; Kildahl-Andersen O; Steinvoll K
    Tidsskr Nor Laegeforen; 2000 Jan; 120(1):15-7. PubMed ID: 10815472
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement accuracy of fever by tympanic and axillary thermometry.
    Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G
    Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A systematic review of the accuracy of peripheral thermometry in estimating core temperatures among febrile critically ill patients.
    Jefferies S; Weatherall M; Young P; Beasley R
    Crit Care Resusc; 2011 Sep; 13(3):194-9. PubMed ID: 21880009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Are electronic thermometry techniques suitable alternatives to traditional mercury in glass thermometry techniques in the paediatric setting?
    Smith J
    J Adv Nurs; 1998 Nov; 28(5):1030-9. PubMed ID: 9840874
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of tympanic and rectal temperatures in term Nigerian neonates.
    Duru CO; Akinbami FO; Orimadegun AE
    BMC Pediatr; 2012 Jun; 12():86. PubMed ID: 22731860
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of body temperature in donkeys using rectal digital, infrared, and mercury-in-glass thermometers during the hot-dry season in a tropical savannah.
    Zakari FO; Ayo JO
    Int J Biometeorol; 2021 Jul; 65(7):1053-1067. PubMed ID: 33616760
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of infrared ear thermometry in adult patients.
    Stavem K; Saxholm H; Smith-Erichsen N
    Intensive Care Med; 1997 Jan; 23(1):100-5. PubMed ID: 9037647
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diagnostic test accuracy of new generation tympanic thermometry in children under different cutoffs: a systematic review and meta-analysis.
    Shi D; Zhang LY; Li HX
    BMC Pediatr; 2020 May; 20(1):210. PubMed ID: 32398036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of temperature measurements by an aural infrared thermometer with measurements by traditional rectal and axillary techniques.
    Yetman RJ; Coody DK; West MS; Montgomery D; Brown M
    J Pediatr; 1993 May; 122(5 Pt 1):769-73. PubMed ID: 8496759
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of infrared ear thermometry with electronic predictive thermometry in a geriatric setting.
    Prentice D; Moreland J
    Geriatr Nurs; 1999; 20(6):314-7. PubMed ID: 10601896
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer.
    Gasim GI; Musa IR; Abdien MT; Adam I
    BMC Res Notes; 2013 May; 6():194. PubMed ID: 23663659
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Temperature measurements with a temporal scanner: systematic review and meta-analysis.
    Geijer H; Udumyan R; Lohse G; Nilsagård Y
    BMJ Open; 2016 Mar; 6(3):e009509. PubMed ID: 27033957
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.
    Kongpanichkul A; Bunjongpak S
    J Med Assoc Thai; 2000 Sep; 83(9):1068-76. PubMed ID: 11075975
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Comparative Study of 3 Different Methods of Temperature Measurement in Children.
    Chatproedprai S; Heamawatanachai K; Tempark T; Wananukul S
    J Med Assoc Thai; 2016 Feb; 99(2):142-9. PubMed ID: 27249893
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temporal artery thermometry in children younger than 5 years: a comparison with rectal thermometry.
    Odinaka KK; Edelu BO; Nwolisa CE; Amamilo IB; Okolo SN
    Pediatr Emerg Care; 2014 Dec; 30(12):867-70. PubMed ID: 25407036
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An evaluation of tympanic thermometry in a paediatric emergency department.
    El-Radhi AS; Patel S
    Emerg Med J; 2006 Jan; 23(1):40-1. PubMed ID: 16373802
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients.
    Hebbar K; Fortenberry JD; Rogers K; Merritt R; Easley K
    Pediatr Crit Care Med; 2005 Sep; 6(5):557-61. PubMed ID: 16148817
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.