221 related articles for article (PubMed ID: 33253376)
1. Impact of electroanatomical mapping-guided lead implantation on procedural outcome of His bundle pacing.
Richter S; Ebert M; Bertagnolli L; Gebauer R; Lucas J; Scheller D; Paetsch I; Hindricks G; Döring M
Europace; 2021 Mar; 23(3):409-420. PubMed ID: 33253376
[TBL] [Abstract][Full Text] [Related]
2. Electroanatomical mapping-guided left bundle branch area pacing in patients with structural heart disease and advanced conduction abnormalities.
Richter S; Gebauer R; Ebert M; Moscoso Ludueña C; Scheller D; Lucas J; König S; Paetsch I; Hindricks G; Döring M
Europace; 2023 Mar; 25(3):1068-1076. PubMed ID: 36581450
[TBL] [Abstract][Full Text] [Related]
3. Novel Wide-Band Dielectric Imaging System Guided Lead Deployment for His Bundle Pacing: A Feasibility Study.
Hua W; Liu X; Gu M; Niu HX; Chen X; Tang M; Zhang S
Front Cardiovasc Med; 2021; 8():712051. PubMed ID: 34540916
[No Abstract] [Full Text] [Related]
4. Novel electroanatomical map for permanent his bundle pacing: the Mont Blanc approach - influence of the learning curve and procedural outcome.
Imnadze G; Vijayaraman P; Bante H; Eitz T; Bergau L; Baridwan N; El Hamriti M; Molatta S; Braun M; Khalaph M; Sohns C; Sommer P
Europace; 2020 Nov; 22(11):1697-1702. PubMed ID: 32778877
[TBL] [Abstract][Full Text] [Related]
5. Direct Visualization of the His Bundle Pacing Lead Placement by 3-Dimensional Electroanatomic Mapping: Technique, Anatomy, and Practical Considerations.
Orlov MV; Koulouridis I; Monin AJ; Casavant D; Maslov M; Erez A; Hicks A; Aoun J; Wylie JV
Circ Arrhythm Electrophysiol; 2019 Feb; 12(2):e006801. PubMed ID: 30739495
[TBL] [Abstract][Full Text] [Related]
6. Electrogram-only guided approach to His bundle pacing with minimal fluoroscopy: A single-center experience.
Zanon F; Marcantoni L; Zuin M; Pastore G; Baracca E; Tiribello A; Raffagnato P; Boaretto G; Roncon L; Vijayaraman P
J Cardiovasc Electrophysiol; 2020 Apr; 31(4):805-812. PubMed ID: 31976602
[TBL] [Abstract][Full Text] [Related]
7. His bundle pacing insights from electroanatomical mapping: Topography and pacing targets.
Orlov MV; Jahangir A; McKelvey D; Armstrong J; Maslov M; Monin AJ; Koulouridis I; Casavant D; Wylie JV
J Cardiovasc Electrophysiol; 2020 Oct; 31(10):2737-2743. PubMed ID: 32666617
[TBL] [Abstract][Full Text] [Related]
8. Comparison of Left Bundle Branch and His Bundle Pacing in Bradycardia Patients.
Hua W; Fan X; Li X; Niu H; Gu M; Ning X; Hu Y; Gold MR; Zhang S
JACC Clin Electrophysiol; 2020 Oct; 6(10):1291-1299. PubMed ID: 33092757
[TBL] [Abstract][Full Text] [Related]
9. His bundle pacing and left bundle branch area pacing: Feasibility and safety.
Saleiro C; Sousa PA; Nogueira C; Mota L; Almeida C; Bragança G; Paisana F
Rev Port Cardiol; 2023 Aug; 42(8):683-691. PubMed ID: 36958571
[TBL] [Abstract][Full Text] [Related]
10. Low Fluoroscopy Permanent His Bundle Pacing Using Electroanatomic Mapping: A Feasibility Study.
Sharma PS; Huang HD; Trohman RG; Naperkowski A; Ellenbogen KA; Vijayaraman P
Circ Arrhythm Electrophysiol; 2019 Feb; 12(2):e006967. PubMed ID: 30704289
[TBL] [Abstract][Full Text] [Related]
11. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice.
Sharma PS; Dandamudi G; Naperkowski A; Oren JW; Storm RH; Ellenbogen KA; Vijayaraman P
Heart Rhythm; 2015 Feb; 12(2):305-12. PubMed ID: 25446158
[TBL] [Abstract][Full Text] [Related]
12. His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study.
Keene D; Arnold AD; Jastrzębski M; Burri H; Zweibel S; Crespo E; Chandrasekaran B; Bassi S; Joghetaei N; Swift M; Moskal P; Francis DP; Foley P; Shun-Shin MJ; Whinnett ZI
J Cardiovasc Electrophysiol; 2019 Oct; 30(10):1984-1993. PubMed ID: 31310403
[TBL] [Abstract][Full Text] [Related]
13. Permanent His-bundle pacing using distal His-bundle electrogram-guided approach in patients with atrioventricular block.
Suga K; Kato H; Inden Y; Yanagisawa S; Murakami H; Kada K; Tsuboi N; Murohara T
Pacing Clin Electrophysiol; 2021 Nov; 44(11):1907-1917. PubMed ID: 34520042
[TBL] [Abstract][Full Text] [Related]
14. Can permanent His bundle pacing be safely started by operators new to this technique? Data from a multicenter registry.
Chaumont C; Auquier N; Milhem A; Mirolo A; Al Arnaout A; Popescu E; Viart G; Godin B; Gillibert A; Savouré A; Eltchaninoff H; Anselme F
J Cardiovasc Electrophysiol; 2021 Feb; 32(2):417-427. PubMed ID: 33373093
[TBL] [Abstract][Full Text] [Related]
15. Physiologic lead placement with electroanatomic mapping: A case series.
Baman JR; Garg V; Kalluri AG; Wasserlauf J; Trivedi A; Knight BP; Sharma PS; Verma N
J Cardiovasc Electrophysiol; 2021 Dec; 32(12):3195-3202. PubMed ID: 34665491
[TBL] [Abstract][Full Text] [Related]
16. Comparison between his-bundle pacing and left bundle branch pacing in patients with atrioventricular block.
Hu Y; Li H; Gu M; Hua W; Niu H; Zhang N; Liu X; Chen X; Hou C; Zhou X; Zhang S
J Interv Card Electrophysiol; 2021 Oct; 62(1):63-73. PubMed ID: 32954478
[TBL] [Abstract][Full Text] [Related]
17. Comparison between His-bundle pacing guided by Ensite NavX system and conventional fluoroscopy.
Hu Y; Ding L; Hua W; Gu M; Cai M; Chen X; Fan X; Niu H; Zhang S
J Interv Card Electrophysiol; 2020 Jan; 57(1):107-114. PubMed ID: 31814064
[TBL] [Abstract][Full Text] [Related]
18. Atrioventricular junction ablation in patients with conduction system pacing leads: A comparison of His-bundle vs left bundle branch area pacing leads.
Pillai A; Kolominsky J; Koneru JN; Kron J; Shepard RK; Kalahasty G; Huang W; Verma A; Ellenbogen KA
Heart Rhythm; 2022 Jul; 19(7):1116-1123. PubMed ID: 35351624
[TBL] [Abstract][Full Text] [Related]
19. Result of the Physiologic Pacing Registry, an international multicenter prospective observational study of conduction system pacing.
Vazquez PM; Mohamed U; Zanon F; Lustgarten DL; Atwater B; Whinnett ZI; Curila K; Dinerman J; Molina-Lerma M; Wiley J; Grammatico A; Lee K; Vijayaraman P
Heart Rhythm; 2023 Dec; 20(12):1617-1625. PubMed ID: 37348800
[TBL] [Abstract][Full Text] [Related]
20. Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience.
Su L; Wu S; Wang S; Wang Z; Xiao F; Shan P; Zhou H; Huang Z; Xu L; Huang W
Europace; 2019 May; 21(5):763-770. PubMed ID: 30561576
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]