These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 33255848)

  • 1. In Vivo Deformation and Strain Measurements in Human Bone Using Digital Volume Correlation (DVC) and 3T Clinical MRI.
    Tavana S; N Clark J; Newell N; Calder JD; Hansen U
    Materials (Basel); 2020 Nov; 13(23):. PubMed ID: 33255848
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantifying deformations and strains in human intervertebral discs using Digital Volume Correlation combined with MRI (DVC-MRI).
    Tavana S; Clark JN; Prior J; Baxan N; Masouros SD; Newell N; Hansen U
    J Biomech; 2020 Mar; 102():109604. PubMed ID: 31928737
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems.
    Peña Fernández M; Barber AH; Blunn GW; Tozzi G
    J Microsc; 2018 Dec; 272(3):213-228. PubMed ID: 30047557
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Uncertainties of synchrotron microCT-based digital volume correlation bone strain measurements under simulated deformation.
    Comini F; Palanca M; Cristofolini L; Dall'Ara E
    J Biomech; 2019 Mar; 86():232-237. PubMed ID: 30736962
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Micro-CT scan optimisation for mechanical loading of tibia with titanium tibial tray: A digital volume correlation zero strain error analysis.
    Wearne LS; Rapagna S; Taylor M; Perilli E
    J Mech Behav Biomed Mater; 2022 Oct; 134():105336. PubMed ID: 35863298
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation.
    Rapagna S; Berahmani S; Wyers CE; van den Bergh JPW; Reynolds KJ; Tozzi G; Janssen D; Perilli E
    J Mech Behav Biomed Mater; 2019 Sep; 97():278-287. PubMed ID: 31146201
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms.
    Palanca M; Bodey AJ; Giorgi M; Viceconti M; Lacroix D; Cristofolini L; Dall'Ara E
    J Biomech; 2017 Jun; 58():27-36. PubMed ID: 28457604
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches.
    Palanca M; Tozzi G; Cristofolini L; Viceconti M; Dall'Ara E
    J Biomech Eng; 2015 Jul; 137(7):. PubMed ID: 25807338
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone.
    Liu L; Morgan EF
    J Biomech; 2007; 40(15):3516-20. PubMed ID: 17570374
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bone metastases do not affect the measurement uncertainties of a global digital volume correlation algorithm.
    Cavazzoni G; Cristofolini L; Dall'Ara E; Palanca M
    Front Bioeng Biotechnol; 2023; 11():1152358. PubMed ID: 37008039
    [No Abstract]   [Full Text] [Related]  

  • 11. Digital volume correlation can be used to estimate local strains in natural and augmented vertebrae: An organ-level study.
    Palanca M; Cristofolini L; Dall'Ara E; Curto M; Innocente F; Danesi V; Tozzi G
    J Biomech; 2016 Dec; 49(16):3882-3890. PubMed ID: 27814973
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: Local analysis on bone and cement-bone microstructures.
    Tozzi G; Dall'Ara E; Palanca M; Curto M; Innocente F; Cristofolini L
    J Mech Behav Biomed Mater; 2017 Mar; 67():117-126. PubMed ID: 27992842
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spatial resolution and measurement uncertainty of strains in bone and bone-cement interface using digital volume correlation.
    Zhu ML; Zhang QH; Lupton C; Tong J
    J Mech Behav Biomed Mater; 2016 Apr; 57():269-79. PubMed ID: 26741534
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review.
    Roberts BC; Perilli E; Reynolds KJ
    J Biomech; 2014 Mar; 47(5):923-34. PubMed ID: 24529357
    [TBL] [Abstract][Full Text] [Related]  

  • 15. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study.
    Dall'Ara E; Barber D; Viceconti M
    J Biomech; 2014 Sep; 47(12):2956-63. PubMed ID: 25113806
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo.
    Disney CM; Lee PD; Hoyland JA; Sherratt MJ; Bay BK
    J Microsc; 2018 Dec; 272(3):165-179. PubMed ID: 29655273
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of Internal Implantation Strains in Analogue Bone Using DVC.
    Marter A; Burson-Thomas C; Dickinson A; Rankin K; Mavrogordato M; Pierron F; Browne M
    Materials (Basel); 2020 Sep; 13(18):. PubMed ID: 32932608
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression.
    Gillard F; Boardman R; Mavrogordato M; Hollis D; Sinclair I; Pierron F; Browne M
    J Mech Behav Biomed Mater; 2014 Jan; 29():480-99. PubMed ID: 24212359
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Micromechanical evaluation of cortical bone using in situ XCT indentation and digital volume correlation.
    Karali A; Kao AP; Zekonyte J; Blunn G; Tozzi G
    J Mech Behav Biomed Mater; 2021 Mar; 115():104298. PubMed ID: 33445104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Full-Field Strain Uncertainties and Residuals at the Cartilage-Bone Interface in Unstained Tissues Using Propagation-Based Phase-Contrast XCT and Digital Volume Correlation.
    Tozzi G; Peña Fernández M; Davis S; Karali A; Kao AP; Blunn G
    Materials (Basel); 2020 Jun; 13(11):. PubMed ID: 32516970
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.