209 related articles for article (PubMed ID: 33259939)
1. Multiplex LC-MS/MS for simultaneous determination of 25-hydroxyvitamin D, 24,25-dihydroxyvitamin D
Ko DH; Jun SH; Nam Y; Song SH; Han M; Yun YM; Lee K; Song J
J Steroid Biochem Mol Biol; 2021 Feb; 206():105796. PubMed ID: 33259939
[TBL] [Abstract][Full Text] [Related]
2. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.
Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F
Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091
[TBL] [Abstract][Full Text] [Related]
3. Candidate Reference Measurement Procedure for the Determination of (24R),25-Dihydroxyvitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry.
Tai SS; Nelson MA
Anal Chem; 2015 Aug; 87(15):7964-70. PubMed ID: 26171884
[TBL] [Abstract][Full Text] [Related]
4. Clinical utility of simultaneous quantitation of 25-hydroxyvitamin D and 24,25-dihydroxyvitamin D by LC-MS/MS involving derivatization with DMEQ-TAD.
Kaufmann M; Gallagher JC; Peacock M; Schlingmann KP; Konrad M; DeLuca HF; Sigueiro R; Lopez B; Mourino A; Maestro M; St-Arnaud R; Finkelstein JS; Cooper DP; Jones G
J Clin Endocrinol Metab; 2014 Jul; 99(7):2567-74. PubMed ID: 24670084
[TBL] [Abstract][Full Text] [Related]
5. Clinical Utility of Measurement of Vitamin D-Binding Protein and Calculation of Bioavailable Vitamin D in Assessment of Vitamin D Status.
Kim HJ; Ji M; Song J; Moon HW; Hur M; Yun YM
Ann Lab Med; 2017 Jan; 37(1):34-38. PubMed ID: 27834063
[TBL] [Abstract][Full Text] [Related]
6. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum.
van den Ouweland JM; Beijers AM; van Daal H
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():195-202. PubMed ID: 25125396
[TBL] [Abstract][Full Text] [Related]
7. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
[TBL] [Abstract][Full Text] [Related]
8. Two-dimensional liquid chromatography coupled to tandem mass spectrometry for vitamin D metabolite profiling including the C3-epimer-25-monohydroxyvitamin D3.
Mena-Bravo A; Priego-Capote F; Luque de Castro MD
J Chromatogr A; 2016 Jun; 1451():50-57. PubMed ID: 27180887
[TBL] [Abstract][Full Text] [Related]
9. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum.
Jenkinson C; Taylor AE; Hassan-Smith ZK; Adams JS; Stewart PM; Hewison M; Keevil BG
J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Mar; 1014():56-63. PubMed ID: 26874878
[TBL] [Abstract][Full Text] [Related]
10. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.
Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873
[TBL] [Abstract][Full Text] [Related]
11. A novel high-performance liquid chromatographic assay for vitamin D metabolites using a coulometric electrochemical detector.
Masuda S; Okano T; Kamao M; Kanedai Y; Kobayashi T
J Pharm Biomed Anal; 1997 Jun; 15(9-10):1497-502. PubMed ID: 9226581
[TBL] [Abstract][Full Text] [Related]
12. 24,25-Dihydroxyvitamin d3 and vitamin D status of community-dwelling black and white Americans.
Berg AH; Powe CE; Evans MK; Wenger J; Ortiz G; Zonderman AB; Suntharalingam P; Lucchesi K; Powe NR; Karumanchi SA; Thadhani RI
Clin Chem; 2015 Jun; 61(6):877-84. PubMed ID: 25922442
[TBL] [Abstract][Full Text] [Related]
13. Comparison of Two ELISA Methods and Mass Spectrometry for Measurement of Vitamin D-Binding Protein: Implications for the Assessment of Bioavailable Vitamin D Concentrations Across Genotypes.
Denburg MR; Hoofnagle AN; Sayed S; Gupta J; de Boer IH; Appel LJ; Durazo-Arvizu R; Whitehead K; Feldman HI; Leonard MB;
J Bone Miner Res; 2016 Jun; 31(6):1128-36. PubMed ID: 27250744
[TBL] [Abstract][Full Text] [Related]
14. Dysregulated mineral metabolism in patients with acute kidney injury and risk of adverse outcomes.
Leaf DE; Waikar SS; Wolf M; Cremers S; Bhan I; Stern L
Clin Endocrinol (Oxf); 2013 Oct; 79(4):491-8. PubMed ID: 23414198
[TBL] [Abstract][Full Text] [Related]
15. [Measurement of 25-hydroxyvitamin D3 in human serum by liquid chromatography-tandem mass spectrometry and the control for analytical conditions].
Zheng X; Ma A; Zhang H; Wang Z; Wang Q; Liang H
Wei Sheng Yan Jiu; 2012 May; 41(3):485-8, 492. PubMed ID: 23050454
[TBL] [Abstract][Full Text] [Related]
16. [Assessment of Vitamin D Metabolism by LC-MS/MS].
Ishige T; Satoh M; Ogawa S; Nishimura M; Higashi T; Nomura F
Rinsho Byori; 2015 Apr; 63(4):457-64. PubMed ID: 26536779
[TBL] [Abstract][Full Text] [Related]
17. Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE).
Thibeault D; Caron N; Djiana R; Kremer R; Blank D
J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():120-7. PubMed ID: 22265352
[TBL] [Abstract][Full Text] [Related]
18. Significance of serum 24,25-dihydroxyvitamin D in the assessment of vitamin D status: a double-edged sword?
Cashman KD; Hayes A; Galvin K; Merkel J; Jones G; Kaufmann M; Hoofnagle AN; Carter GD; Durazo-Arvizu RA; Sempos CT
Clin Chem; 2015 Apr; 61(4):636-45. PubMed ID: 25710460
[TBL] [Abstract][Full Text] [Related]
19. The serum vitamin D metabolome: What we know and what is still to discover.
Tuckey RC; Cheng CYS; Slominski AT
J Steroid Biochem Mol Biol; 2019 Feb; 186():4-21. PubMed ID: 30205156
[TBL] [Abstract][Full Text] [Related]
20. Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay.
van den Ouweland JM; Beijers AM; Demacker PN; van Daal H
J Chromatogr B Analyt Technol Biomed Life Sci; 2010 May; 878(15-16):1163-8. PubMed ID: 20381436
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]