166 related articles for article (PubMed ID: 33264638)
1. Multicentre, deep learning, synthetic-CT generation for ano-rectal MR-only radiotherapy treatment planning.
Bird D; Nix MG; McCallum H; Teo M; Gilbert A; Casanova N; Cooper R; Buckley DL; Sebag-Montefiore D; Speight R; Al-Qaisieh B; Henry AM
Radiother Oncol; 2021 Mar; 156():23-28. PubMed ID: 33264638
[TBL] [Abstract][Full Text] [Related]
2. Evaluating the Hounsfield unit assignment and dose differences between CT-based standard and deep learning-based synthetic CT images for MRI-only radiation therapy of the head and neck.
Singhrao K; Dugan CL; Calvin C; Pelayo L; Yom SS; Chan JW; Scholey JE; Singer L
J Appl Clin Med Phys; 2024 Jan; 25(1):e14239. PubMed ID: 38128040
[TBL] [Abstract][Full Text] [Related]
3. Deep learning MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers.
Bird D; Speight R; Andersson S; Wingqvist J; Al-Qaisieh B
Radiother Oncol; 2024 Feb; 191():110052. PubMed ID: 38096921
[TBL] [Abstract][Full Text] [Related]
4. Comprehensive dose evaluation of a Deep Learning based synthetic Computed Tomography algorithm for pelvic Magnetic Resonance-only radiotherapy.
Wyatt JJ; Kaushik S; Cozzini C; Pearson RA; Petit S; Capala M; Hernandez-Tamames JA; Hideghéty K; Maxwell RJ; Wiesinger F; McCallum HM
Radiother Oncol; 2023 Jul; 184():109692. PubMed ID: 37150446
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.
Dinkla AM; Florkow MC; Maspero M; Savenije MHF; Zijlstra F; Doornaert PAH; van Stralen M; Philippens MEP; van den Berg CAT; Seevinck PR
Med Phys; 2019 Sep; 46(9):4095-4104. PubMed ID: 31206701
[TBL] [Abstract][Full Text] [Related]
6. Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy.
Maspero M; Savenije MHF; Dinkla AM; Seevinck PR; Intven MPW; Jurgenliemk-Schulz IM; Kerkmeijer LGW; van den Berg CAT
Phys Med Biol; 2018 Sep; 63(18):185001. PubMed ID: 30109989
[TBL] [Abstract][Full Text] [Related]
7. Multi-sequence MR image-based synthetic CT generation using a generative adversarial network for head and neck MRI-only radiotherapy.
Qi M; Li Y; Wu A; Jia Q; Li B; Sun W; Dai Z; Lu X; Zhou L; Deng X; Song T
Med Phys; 2020 Apr; 47(4):1880-1894. PubMed ID: 32027027
[TBL] [Abstract][Full Text] [Related]
8. Patch-based generative adversarial neural network models for head and neck MR-only planning.
Klages P; Benslimane I; Riyahi S; Jiang J; Hunt M; Deasy JO; Veeraraghavan H; Tyagi N
Med Phys; 2020 Feb; 47(2):626-642. PubMed ID: 31733164
[TBL] [Abstract][Full Text] [Related]
9. Magnetic resonance-based synthetic computed tomography images generated using generative adversarial networks for nasopharyngeal carcinoma radiotherapy treatment planning.
Peng Y; Chen S; Qin A; Chen M; Gao X; Liu Y; Miao J; Gu H; Zhao C; Deng X; Qi Z
Radiother Oncol; 2020 Sep; 150():217-224. PubMed ID: 32622781
[TBL] [Abstract][Full Text] [Related]
10. A high-performance method of deep learning for prostate MR-only radiotherapy planning using an optimized Pix2Pix architecture.
Tahri S; Barateau A; Cadin C; Chourak H; Ribault S; Nozahic F; Acosta O; Dowling JA; Greer PB; Largent A; Lafond C; De Crevoisier R; Nunes JC
Phys Med; 2022 Nov; 103():108-118. PubMed ID: 36272328
[TBL] [Abstract][Full Text] [Related]
11. Feasibility of synthetic computed tomography generated with an adversarial network for multi-sequence magnetic resonance-based brain radiotherapy.
Koike Y; Akino Y; Sumida I; Shiomi H; Mizuno H; Yagi M; Isohashi F; Seo Y; Suzuki O; Ogawa K
J Radiat Res; 2020 Jan; 61(1):92-103. PubMed ID: 31822894
[TBL] [Abstract][Full Text] [Related]
12. A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases.
Cusumano D; Lenkowicz J; Votta C; Boldrini L; Placidi L; Catucci F; Dinapoli N; Antonelli MV; Romano A; De Luca V; Chiloiro G; Indovina L; Valentini V
Radiother Oncol; 2020 Dec; 153():205-212. PubMed ID: 33075394
[TBL] [Abstract][Full Text] [Related]
13. Generation of abdominal synthetic CTs from 0.35T MR images using generative adversarial networks for MR-only liver radiotherapy.
Fu J; Singhrao K; Cao M; Yu V; Santhanam AP; Yang Y; Guo M; Raldow AC; Ruan D; Lewis JH
Biomed Phys Eng Express; 2020 Jan; 6(1):015033. PubMed ID: 33438621
[TBL] [Abstract][Full Text] [Related]
14. A practical methodology to improve the dosimetric accuracy of MR-based radiotherapy simulation for brain tumors.
Lui JCF; Tang AM; Law CC; Lee JCY; Lee FKH; Chiu J; Wong KH
Phys Med; 2021 Nov; 91():1-12. PubMed ID: 34678686
[TBL] [Abstract][Full Text] [Related]
15. Applying a commercial atlas-based synthetic Computed Tomography algorithm to patients with hip prostheses for prostate Magnetic Resonance-only radiotherapy.
Wyatt J; McCallum H
Radiother Oncol; 2019 Apr; 133():100-105. PubMed ID: 30935564
[TBL] [Abstract][Full Text] [Related]
16. A deep learning approach to generate synthetic CT in low field MR-guided radiotherapy for lung cases.
Lenkowicz J; Votta C; Nardini M; Quaranta F; Catucci F; Boldrini L; Vagni M; Menna S; Placidi L; Romano A; Chiloiro G; Gambacorta MA; Mattiucci GC; Indovina L; Valentini V; Cusumano D
Radiother Oncol; 2022 Nov; 176():31-38. PubMed ID: 36063982
[TBL] [Abstract][Full Text] [Related]
17. Deep learning approaches using 2D and 3D convolutional neural networks for generating male pelvic synthetic computed tomography from magnetic resonance imaging.
Fu J; Yang Y; Singhrao K; Ruan D; Chu FI; Low DA; Lewis JH
Med Phys; 2019 Sep; 46(9):3788-3798. PubMed ID: 31220353
[TBL] [Abstract][Full Text] [Related]
18. MR to CT synthesis with multicenter data in the pelvic area using a conditional generative adversarial network.
Brou Boni KND; Klein J; Vanquin L; Wagner A; Lacornerie T; Pasquier D; Reynaert N
Phys Med Biol; 2020 Apr; 65(7):075002. PubMed ID: 32053808
[TBL] [Abstract][Full Text] [Related]
19. Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy.
Olberg S; Zhang H; Kennedy WR; Chun J; Rodriguez V; Zoberi I; Thomas MA; Kim JS; Mutic S; Green OL; Park JC
Med Phys; 2019 Sep; 46(9):4135-4147. PubMed ID: 31309586
[TBL] [Abstract][Full Text] [Related]
20. A deep learning model to generate synthetic CT for prostate MR-only radiotherapy dose planning: a multicenter study.
Tahri S; Texier B; Nunes JC; Hemon C; Lekieffre P; Collot E; Chourak H; Le Guevelou J; Greer P; Dowling J; Acosta O; Bessieres I; Marage L; Boue-Rafle A; De Crevoisier R; Lafond C; Barateau A
Front Oncol; 2023; 13():1279750. PubMed ID: 38090490
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]