BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 33264638)

  • 1. Multicentre, deep learning, synthetic-CT generation for ano-rectal MR-only radiotherapy treatment planning.
    Bird D; Nix MG; McCallum H; Teo M; Gilbert A; Casanova N; Cooper R; Buckley DL; Sebag-Montefiore D; Speight R; Al-Qaisieh B; Henry AM
    Radiother Oncol; 2021 Mar; 156():23-28. PubMed ID: 33264638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluating the Hounsfield unit assignment and dose differences between CT-based standard and deep learning-based synthetic CT images for MRI-only radiation therapy of the head and neck.
    Singhrao K; Dugan CL; Calvin C; Pelayo L; Yom SS; Chan JW; Scholey JE; Singer L
    J Appl Clin Med Phys; 2024 Jan; 25(1):e14239. PubMed ID: 38128040
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Deep learning MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers.
    Bird D; Speight R; Andersson S; Wingqvist J; Al-Qaisieh B
    Radiother Oncol; 2024 Feb; 191():110052. PubMed ID: 38096921
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comprehensive dose evaluation of a Deep Learning based synthetic Computed Tomography algorithm for pelvic Magnetic Resonance-only radiotherapy.
    Wyatt JJ; Kaushik S; Cozzini C; Pearson RA; Petit S; Capala M; Hernandez-Tamames JA; Hideghéty K; Maxwell RJ; Wiesinger F; McCallum HM
    Radiother Oncol; 2023 Jul; 184():109692. PubMed ID: 37150446
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.
    Dinkla AM; Florkow MC; Maspero M; Savenije MHF; Zijlstra F; Doornaert PAH; van Stralen M; Philippens MEP; van den Berg CAT; Seevinck PR
    Med Phys; 2019 Sep; 46(9):4095-4104. PubMed ID: 31206701
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy.
    Maspero M; Savenije MHF; Dinkla AM; Seevinck PR; Intven MPW; Jurgenliemk-Schulz IM; Kerkmeijer LGW; van den Berg CAT
    Phys Med Biol; 2018 Sep; 63(18):185001. PubMed ID: 30109989
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multi-sequence MR image-based synthetic CT generation using a generative adversarial network for head and neck MRI-only radiotherapy.
    Qi M; Li Y; Wu A; Jia Q; Li B; Sun W; Dai Z; Lu X; Zhou L; Deng X; Song T
    Med Phys; 2020 Apr; 47(4):1880-1894. PubMed ID: 32027027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Patch-based generative adversarial neural network models for head and neck MR-only planning.
    Klages P; Benslimane I; Riyahi S; Jiang J; Hunt M; Deasy JO; Veeraraghavan H; Tyagi N
    Med Phys; 2020 Feb; 47(2):626-642. PubMed ID: 31733164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetic resonance-based synthetic computed tomography images generated using generative adversarial networks for nasopharyngeal carcinoma radiotherapy treatment planning.
    Peng Y; Chen S; Qin A; Chen M; Gao X; Liu Y; Miao J; Gu H; Zhao C; Deng X; Qi Z
    Radiother Oncol; 2020 Sep; 150():217-224. PubMed ID: 32622781
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A high-performance method of deep learning for prostate MR-only radiotherapy planning using an optimized Pix2Pix architecture.
    Tahri S; Barateau A; Cadin C; Chourak H; Ribault S; Nozahic F; Acosta O; Dowling JA; Greer PB; Largent A; Lafond C; De Crevoisier R; Nunes JC
    Phys Med; 2022 Nov; 103():108-118. PubMed ID: 36272328
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility of synthetic computed tomography generated with an adversarial network for multi-sequence magnetic resonance-based brain radiotherapy.
    Koike Y; Akino Y; Sumida I; Shiomi H; Mizuno H; Yagi M; Isohashi F; Seo Y; Suzuki O; Ogawa K
    J Radiat Res; 2020 Jan; 61(1):92-103. PubMed ID: 31822894
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases.
    Cusumano D; Lenkowicz J; Votta C; Boldrini L; Placidi L; Catucci F; Dinapoli N; Antonelli MV; Romano A; De Luca V; Chiloiro G; Indovina L; Valentini V
    Radiother Oncol; 2020 Dec; 153():205-212. PubMed ID: 33075394
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Generation of abdominal synthetic CTs from 0.35T MR images using generative adversarial networks for MR-only liver radiotherapy.
    Fu J; Singhrao K; Cao M; Yu V; Santhanam AP; Yang Y; Guo M; Raldow AC; Ruan D; Lewis JH
    Biomed Phys Eng Express; 2020 Jan; 6(1):015033. PubMed ID: 33438621
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A practical methodology to improve the dosimetric accuracy of MR-based radiotherapy simulation for brain tumors.
    Lui JCF; Tang AM; Law CC; Lee JCY; Lee FKH; Chiu J; Wong KH
    Phys Med; 2021 Nov; 91():1-12. PubMed ID: 34678686
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Applying a commercial atlas-based synthetic Computed Tomography algorithm to patients with hip prostheses for prostate Magnetic Resonance-only radiotherapy.
    Wyatt J; McCallum H
    Radiother Oncol; 2019 Apr; 133():100-105. PubMed ID: 30935564
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A deep learning approach to generate synthetic CT in low field MR-guided radiotherapy for lung cases.
    Lenkowicz J; Votta C; Nardini M; Quaranta F; Catucci F; Boldrini L; Vagni M; Menna S; Placidi L; Romano A; Chiloiro G; Gambacorta MA; Mattiucci GC; Indovina L; Valentini V; Cusumano D
    Radiother Oncol; 2022 Nov; 176():31-38. PubMed ID: 36063982
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Deep learning approaches using 2D and 3D convolutional neural networks for generating male pelvic synthetic computed tomography from magnetic resonance imaging.
    Fu J; Yang Y; Singhrao K; Ruan D; Chu FI; Low DA; Lewis JH
    Med Phys; 2019 Sep; 46(9):3788-3798. PubMed ID: 31220353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. MR to CT synthesis with multicenter data in the pelvic area using a conditional generative adversarial network.
    Brou Boni KND; Klein J; Vanquin L; Wagner A; Lacornerie T; Pasquier D; Reynaert N
    Phys Med Biol; 2020 Apr; 65(7):075002. PubMed ID: 32053808
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy.
    Olberg S; Zhang H; Kennedy WR; Chun J; Rodriguez V; Zoberi I; Thomas MA; Kim JS; Mutic S; Green OL; Park JC
    Med Phys; 2019 Sep; 46(9):4135-4147. PubMed ID: 31309586
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A deep learning model to generate synthetic CT for prostate MR-only radiotherapy dose planning: a multicenter study.
    Tahri S; Texier B; Nunes JC; Hemon C; Lekieffre P; Collot E; Chourak H; Le Guevelou J; Greer P; Dowling J; Acosta O; Bessieres I; Marage L; Boue-Rafle A; De Crevoisier R; Lafond C; Barateau A
    Front Oncol; 2023; 13():1279750. PubMed ID: 38090490
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.