BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 33273278)

  • 1. Cyclodiode Laser as the First Surgical Approach in Childhood Glaucoma Under the Age of 8 Years.
    Sakaorat P; Mohamed-Noriega J; Sharara A; Daniel MC; Brookes J
    J Glaucoma; 2021 Apr; 30(4):352-356. PubMed ID: 33273278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diode laser cyclophotocoagulation: role in the management of refractory pediatric glaucomas.
    Kirwan JF; Shah P; Khaw PT
    Ophthalmology; 2002 Feb; 109(2):316-23. PubMed ID: 11825816
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cyclodiode photocoagulation for refractory glaucoma after penetrating keratoplasty.
    Shah P; Lee GA; Kirwan JK; Bunce C; Bloom PA; Ficker LA; Khaw PT
    Ophthalmology; 2001 Nov; 108(11):1986-91. PubMed ID: 11713066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Audible pops during cyclodiode procedures.
    Rebolleda G; Muñoz FJ; Murube J
    J Glaucoma; 1999 Jun; 8(3):177-83. PubMed ID: 10376257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diode laser transscleral cyclophotocoagulation for the treatment of refractory glaucoma after penetrating keratoplasty.
    Ocakoglu O; Arslan OS; Kayiran A
    Curr Eye Res; 2005 Jul; 30(7):569-74. PubMed ID: 16020291
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term limitations and complications of trans-scleral diode laser cycloablation for refractory glaucoma.
    Scott TM; Ting ER; Vincent SJ; Lee GA
    Clin Exp Ophthalmol; 2023 Mar; 51(2):131-136. PubMed ID: 36307903
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High intensity focused ultrasound cyclodestruction versus cyclodiode treatment of refractory glaucoma: A retrospective comparative study.
    Graber M; Rothschild PR; Khoueir Z; Bluwol E; Benhatchi N; Lachkar Y
    J Fr Ophtalmol; 2018 Sep; 41(7):611-618. PubMed ID: 30139539
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cyclodestructive procedures for refractory glaucoma.
    Chen MF; Kim CH; Coleman AL
    Cochrane Database Syst Rev; 2019 Mar; 3(3):CD012223. PubMed ID: 30852841
    [TBL] [Abstract][Full Text] [Related]  

  • 9. "Cyclodiode". Trans-scleral diode laser cyclophotocoagulation in the treatment of advanced refractory glaucoma.
    Bloom PA; Tsai JC; Sharma K; Miller MH; Rice NS; Hitchings RA; Khaw PT
    Ophthalmology; 1997 Sep; 104(9):1508-19; discussion 1519-20. PubMed ID: 9307649
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term results of transscleral cyclophotocoagulation in refractory pediatric glaucoma patients.
    Autrata R; Rehurek J
    Ophthalmologica; 2003; 217(6):393-400. PubMed ID: 14573971
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficacy of 180° Cyclodiode Transscleral Photocoagulation for Refractory Glaucoma.
    Bezci Aygün F; Mocan MC; Kocabeyoğlu S; İrkeç M
    Turk J Ophthalmol; 2018 Dec; 48(6):299-303. PubMed ID: 30605936
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contact Transscleral Cyclodiode Laser Treatment for Refractory Glaucoma After Penetrating Keratoplasty: Retrospective Long-term Outcomes.
    Tabibian D; Wride N; Birch M; Figueiredo FC
    J Glaucoma; 2019 May; 28(5):440-446. PubMed ID: 30720572
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diode laser cyclophotocoagulation: dose-standardized therapy in end-stage glaucoma.
    Walland MJ
    Aust N Z J Ophthalmol; 1998 May; 26(2):135-9. PubMed ID: 9630294
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surgical management of glaucoma in infants and children with Peters' anomaly: long-term structural and functional outcome.
    Yang LL; Lambert SR; Lynn MJ; Stulting RD
    Ophthalmology; 2004 Jan; 111(1):112-7. PubMed ID: 14711722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison between tube surgery, ND:YAG laser and diode laser cyclophotocoagulation in the management of refractory glaucoma.
    Bloom PA; Clement CI; King A; Noureddin B; Sharma K; Hitchings RA; Khaw PT
    Biomed Res Int; 2013; 2013():371951. PubMed ID: 24222905
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and Safety of Repeated Micropulse Transscleral Diode Cyclophotocoagulation in Advanced Glaucoma.
    Lim EJY; Aquino CM; Lun KWX; Lim DKA; Sng C; Loon SC; Chew PTK; Koh VTC
    J Glaucoma; 2021 Jul; 30(7):566-574. PubMed ID: 33927146
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retrospective review on the outcome and safety of transscleral diode laser cyclophotocoagulation in refractory glaucoma in Chinese patients.
    Cheung JJC; Li KKW; Tang SWK
    Int Ophthalmol; 2019 Jan; 39(1):41-46. PubMed ID: 29230617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of total energy delivery on success rate after contact diode laser transscleral cyclophotocoagulation: a retrospective case review and meta-analysis.
    Hauber FA; Scherer WJ
    J Glaucoma; 2002 Aug; 11(4):329-33. PubMed ID: 12169970
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transvitreal endocyclophotocoagulation.
    Haller JA
    Trans Am Ophthalmol Soc; 1996; 94():589-676. PubMed ID: 8981713
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy and safety of contact transscleral diode laser cyclophotocoagulation for advanced glaucoma.
    Schlote T; Derse M; Rassmann K; Nicaeus T; Dietz K; Thiel HJ
    J Glaucoma; 2001 Aug; 10(4):294-301. PubMed ID: 11558814
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.