These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 33274771)

  • 1. Changes in Internal Carotid Artery Doppler Velocity Measurements With Different Angles of Insonation: A Pilot Study.
    Campbell KA; Kupinski AM; Miele FR; Silva PF; Zierler RE
    J Ultrasound Med; 2021 Sep; 40(9):1937-1948. PubMed ID: 33274771
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of Doppler angle in diagnosis of internal carotid artery stenosis.
    Tola M; Yurdakul M
    J Ultrasound Med; 2006 Sep; 25(9):1187-92. PubMed ID: 16929020
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a Duplex Ultrasound Simulator and Preliminary Validation of Velocity Measurements in Carotid Artery Models.
    Zierler RE; Leotta DF; Sansom K; Aliseda A; Anderson MD; Sheehan FH
    Vasc Endovascular Surg; 2016 Jul; 50(5):309-16. PubMed ID: 27206747
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of insonation angle on peak systolic velocity variation.
    Radparvar JR; Lim G; Chiem AT
    Am J Emerg Med; 2020 Feb; 38(2):173-177. PubMed ID: 30718117
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The importance of Doppler angle of insonation on differentiation between 50-69% and 70-99% carotid artery stenosis.
    Logason K; Bärlin T; Jonsson ML; Boström A; Hårdemark HG; Karacagil S
    Eur J Vasc Endovasc Surg; 2001 Apr; 21(4):311-3. PubMed ID: 11359330
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Duplex ultrasound velocity criteria for the stented carotid artery.
    Lal BK; Hobson RW; Tofighi B; Kapadia I; Cuadra S; Jamil Z
    J Vasc Surg; 2008 Jan; 47(1):63-73. PubMed ID: 18178455
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Carotid artery stenting: is there a need to revise ultrasound velocity criteria?
    Lal BK; Hobson RW; Goldstein J; Chakhtoura EY; Durán WN
    J Vasc Surg; 2004 Jan; 39(1):58-66. PubMed ID: 14718815
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictive multivariate regression to increase the specificity of carotid duplex ultrasound for high-grade stenosis in asymptomatic patients.
    Carnicelli AP; Stone JJ; Doyle A; Chowdhry A; Gillespie DL; Chandra A
    Ann Vasc Surg; 2014 Aug; 28(6):1548-55. PubMed ID: 24530716
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determining in-stent stenosis of carotid arteries by duplex ultrasound criteria.
    Stanziale SF; Wholey MH; Boules TN; Selzer F; Makaroun MS
    J Endovasc Ther; 2005 Jun; 12(3):346-53. PubMed ID: 15943510
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mesenteric flow velocity variations as a function of angle of insonation.
    Rizzo RJ; Sandager G; Astleford P; Payne K; Peterson-Kennedy L; Flinn WR; Yao JS
    J Vasc Surg; 1990 May; 11(5):688-94. PubMed ID: 2186185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gender differences in blood velocities across carotid stenoses.
    Comerota AJ; Salles-Cunha SX; Daoud Y; Jones L; Beebe HG
    J Vasc Surg; 2004 Nov; 40(5):939-44. PubMed ID: 15557908
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of theoretical errors on velocity estimation and accuracy of duplex grading of carotid stenosis.
    Thomas N; Taylor P; Padayachee S
    Ultrasound Med Biol; 2002 Feb; 28(2):191-6. PubMed ID: 11937281
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessing internal carotid artery stenosis with a semiautomated computed tomography angiography tool and duplex ultrasound.
    Müller M; Agten CA; Österreich M; Hoffmann M
    J Vasc Surg; 2015 Jun; 61(6):1449-56. PubMed ID: 25776187
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing duplex follow-up in patients with an asymptomatic internal carotid artery stenosis of less than 60%.
    Lovelace TD; Moneta GL; Abou-Zamzam AM; Edwards JM; Yeager RA; Landry GJ; Taylor LM; Porter JM
    J Vasc Surg; 2001 Jan; 33(1):56-61. PubMed ID: 11137924
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Carotid artery velocity characteristics after carotid artery angioplasty and stenting.
    Chahwan S; Miller MT; Pigott JP; Whalen RC; Jones L; Comerota AJ
    J Vasc Surg; 2007 Mar; 45(3):523-6. PubMed ID: 17257803
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Center specific duplex Doppler threshold values in carotid artery stenosis].
    Yurdakul M; Tola M; Ozdemir E; Işiksalan Ozbülbül N; Cumhur T
    Tani Girisim Radyol; 2004 Jun; 10(2):167-72. PubMed ID: 15236136
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Study on correlation between retinal vessel morphology or ocular hemodynamic parameter and internal carotid artery stenosis].
    Li HY; Wang H; Zhang XJ; Feng YH; Wang ZC; Wang YL
    Zhonghua Yan Ke Za Zhi; 2016 Dec; 52(12):905-910. PubMed ID: 27998454
    [No Abstract]   [Full Text] [Related]  

  • 18. Carotid artery stent type influences duplex ultrasonography derived peak systolic velocity: findings of an in-vitro model.
    Spies C; Doshi R; Spoon J; Snell RJ
    Catheter Cardiovasc Interv; 2007 Aug; 70(2):309-15. PubMed ID: 17630677
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrasound velocity criteria for carotid in-stent restenosis.
    Chi YW; White CJ; Woods TC; Goldman CK
    Catheter Cardiovasc Interv; 2007 Feb; 69(3):349-54. PubMed ID: 17171655
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Grading carotid intrastent restenosis: a 6-year follow-up study.
    Setacci C; Chisci E; Setacci F; Iacoponi F; de Donato G
    Stroke; 2008 Apr; 39(4):1189-96. PubMed ID: 18292382
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.