230 related articles for article (PubMed ID: 33277901)
1. Fully Automated Optical Hematocrit Measurement From Dried Blood Spots.
Luginbühl M; Fischer Y; Gaugler S
J Anal Toxicol; 2020 Dec; ():. PubMed ID: 33277901
[TBL] [Abstract][Full Text] [Related]
2. Fully automated correction for the hematocrit bias of non-volumetric dried blood spot phosphatidylethanol analysis.
Luginbühl M; Stöth F; Weinmann W; Gaugler S
Alcohol; 2021 Aug; 94():17-23. PubMed ID: 33865941
[TBL] [Abstract][Full Text] [Related]
3. Addressing New Possibilities and New Challenges: Automated Nondestructive Hematocrit Normalization for Dried Blood Spots.
Luginbühl M; Gaugler S
Ther Drug Monit; 2021 Jun; 43(3):346-350. PubMed ID: 33973966
[TBL] [Abstract][Full Text] [Related]
4. Application of non-contact hematocrit prediction technologies to overcome hematocrit effects on immunosuppressant quantification from dried blood spots.
Deprez S; Heughebaert L; Boffel L; Stove CP
Talanta; 2023 Mar; 254():124111. PubMed ID: 36462285
[TBL] [Abstract][Full Text] [Related]
5. In-depth evaluation of automated non-contact reflectance-based hematocrit prediction of dried blood spots.
Boffel L; Heughebaert L; Lambrecht S; Luginbühl M; Stove CP
Analyst; 2022 Nov; 147(23):5445-5454. PubMed ID: 36317701
[TBL] [Abstract][Full Text] [Related]
6. Correction for the Hematocrit Bias in Dried Blood Spot Analysis Using a Nondestructive, Single-Wavelength Reflectance-Based Hematocrit Prediction Method.
Capiau S; Wilk LS; De Kesel PMM; Aalders MCG; Stove CP
Anal Chem; 2018 Feb; 90(3):1795-1804. PubMed ID: 29281263
[TBL] [Abstract][Full Text] [Related]
7. Fully Automated Dried Blood Spot Extraction coupled to Liquid Chromatography-tandem Mass Spectrometry for Therapeutic Drug Monitoring of Immunosuppressants.
Deprez S; Stove CP
J Chromatogr A; 2021 Sep; 1653():462430. PubMed ID: 34384960
[TBL] [Abstract][Full Text] [Related]
8. Hematocrit-Independent Quantitation of Stimulants in Dried Blood Spots: Pipet versus Microfluidic-Based Volumetric Sampling Coupled with Automated Flow-Through Desorption and Online Solid Phase Extraction-LC-MS/MS Bioanalysis.
Verplaetse R; Henion J
Anal Chem; 2016 Jul; 88(13):6789-96. PubMed ID: 27270226
[TBL] [Abstract][Full Text] [Related]
9. Determination of moxifloxacin in dried blood spots using LC-MS/MS and the impact of the hematocrit and blood volume.
Vu DH; Koster RA; Alffenaar JW; Brouwers JR; Uges DR
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 May; 879(15-16):1063-70. PubMed ID: 21459055
[TBL] [Abstract][Full Text] [Related]
10. Near-infrared-based hematocrit prediction of dried blood spots: An in-depth evaluation.
Delahaye L; Heughebaert L; Lühr C; Lambrecht S; Stove CP
Clin Chim Acta; 2021 Dec; 523():239-246. PubMed ID: 34624275
[TBL] [Abstract][Full Text] [Related]
11. Development and validation of an LC-MS/MS method for the analysis of ivermectin in plasma, whole blood, and dried blood spots using a fully automatic extraction system.
Duthaler U; Suenderhauf C; Gaugler S; Vetter B; Krähenbühl S; Hammann F
J Pharm Biomed Anal; 2019 Aug; 172():18-25. PubMed ID: 31015095
[TBL] [Abstract][Full Text] [Related]
12. Prediction of the hematocrit of dried blood spots via potassium measurement on a routine clinical chemistry analyzer.
Capiau S; Stove VV; Lambert WE; Stove CP
Anal Chem; 2013 Jan; 85(1):404-10. PubMed ID: 23190205
[TBL] [Abstract][Full Text] [Related]
13. Potassium-based algorithm allows correction for the hematocrit bias in quantitative analysis of caffeine and its major metabolite in dried blood spots.
De Kesel PM; Capiau S; Stove VV; Lambert WE; Stove CP
Anal Bioanal Chem; 2014 Oct; 406(26):6749-55. PubMed ID: 25168119
[TBL] [Abstract][Full Text] [Related]
14. Development of the dried blood spot preparation protocol for comprehensive evaluation of the hematocrit effect.
Cheng CN; Peng YF; Chen JY; Chen GY; Weng TI; Kuo CH
Anal Chim Acta; 2023 Jan; 1239():340650. PubMed ID: 36628747
[TBL] [Abstract][Full Text] [Related]
15. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.
De Kesel PM; Lambert WE; Stove CP
Anal Chim Acta; 2015 Jun; 881():65-73. PubMed ID: 26041521
[TBL] [Abstract][Full Text] [Related]
16. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.
Leuthold LA; Heudi O; Déglon J; Raccuglia M; Augsburger M; Picard F; Kretz O; Thomas A
Anal Chem; 2015 Feb; 87(4):2068-71. PubMed ID: 25607538
[TBL] [Abstract][Full Text] [Related]
17. Fluispotter, a novel automated and wearable device for accurate volume serial dried blood spot sampling.
Adhikari KB; Rohde M; Velschow S; Feldt-Rasmussen U; Johannesen J; Johnsen AH
Bioanalysis; 2020 May; 12(10):665-681. PubMed ID: 32489105
[No Abstract] [Full Text] [Related]
18. Fully automated dried blood spot sample preparation enables the detection of lower molecular mass peptide and non-peptide doping agents by means of LC-HRMS.
Lange T; Thomas A; Walpurgis K; Thevis M
Anal Bioanal Chem; 2020 Jun; 412(15):3765-3777. PubMed ID: 32300840
[TBL] [Abstract][Full Text] [Related]
19. Development and validation of a fully automated online human dried blood spot analysis of bosentan and its metabolites using the Sample Card And Prep DBS System.
Ganz N; Singrasa M; Nicolas L; Gutierrez M; Dingemanse J; Döbelin W; Glinski M
J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 885-886():50-60. PubMed ID: 22227055
[TBL] [Abstract][Full Text] [Related]
20. Development of an LC-MS/MS method to simultaneously quantify therapeutic mAbs and estimate hematocrit values in dried blood spot samples.
Chiu HH; Tsai YJ; Lo C; Liao HW; Lin CH; Tang SC; Kuo CH
Anal Chim Acta; 2022 Jan; 1189():339231. PubMed ID: 34815034
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]