147 related articles for article (PubMed ID: 33279395)
1. Local exhaust ventilation systems for the gross anatomy laboratory.
Zdilla MJ
Morphologie; 2021 Sep; 105(350):237-246. PubMed ID: 33279395
[TBL] [Abstract][Full Text] [Related]
2. Creating an inexpensive yet effective downdraft table for a gross anatomy laboratory: Proof-of-concept.
Zdilla MJ
Morphologie; 2022 Feb; 106(352):28-36. PubMed ID: 33773919
[TBL] [Abstract][Full Text] [Related]
3. [Formaldehyde-reducing efficiency of a newly developed dissection-table-connected local ventilation system in the gross anatomy laboratory room].
Shinoda K; Oba J
Kaibogaku Zasshi; 2010 Mar; 85(1):5-15. PubMed ID: 20384186
[TBL] [Abstract][Full Text] [Related]
4. Characterizing formaldehyde emission rates in a gross anatomy laboratory.
Keil CB; Akbar-Khanzadeh F; Konecny KA
Appl Occup Environ Hyg; 2001 Oct; 16(10):967-72. PubMed ID: 11599546
[TBL] [Abstract][Full Text] [Related]
5. Formaldehyde exposure in gross anatomy laboratory of Suranaree University of Technology: a comparison of area and personal sampling.
Saowakon N; Ngernsoungnern P; Watcharavitoon P; Ngernsoungnern A; Kosanlavit R
Environ Sci Pollut Res Int; 2015 Dec; 22(23):19002-12. PubMed ID: 26233735
[TBL] [Abstract][Full Text] [Related]
6. Formaldehyde exposure in a gross anatomy laboratory--personal exposure level is higher than indoor concentration.
Ohmichi K; Komiyama M; Matsuno Y; Takanashi Y; Miyamoto H; Kadota T; Maekawa M; Toyama Y; Tatsugi Y; Kohno T; Ohmichi M; Mori C
Environ Sci Pollut Res Int; 2006 Mar; 13(2):120-4. PubMed ID: 16612901
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of formaldehyde exposure among gross dissection after modified embalming solution and health assessment.
Soonklang N; Saowakon N
Environ Sci Pollut Res Int; 2022 Sep; 29(43):65642-65654. PubMed ID: 35488160
[TBL] [Abstract][Full Text] [Related]
8. [Formaldehyde concentrations in the breathing zone of medical students during gross anatomy laboratory in Toho University].
Takayanagi M; Sakai M; Ishikawa Y; Murakami K; Kimura A; Kakuta S; Sato F
Kaibogaku Zasshi; 2007 Jun; 82(2):45-51. PubMed ID: 17585598
[TBL] [Abstract][Full Text] [Related]
9. One academic year laboratory and student breathing zone formaldehyde level, measured by gas-piston hand pump at gross anatomy laboratory, Siriraj Hospital, Thailand.
Durongphan A; Amornmettajit N; Rungruang J; Nitimanee E; Panichareon B
Environ Sci Pollut Res Int; 2020 May; 27(14):16521-16527. PubMed ID: 32125638
[TBL] [Abstract][Full Text] [Related]
10. Formaldehyde concentration in the air and in cadavers at the gross anatomy laboratory in Hiroshima University.
Kurose T; Kodera H; Aoyama H; Kawamata S
Hiroshima J Med Sci; 2004 Dec; 53(3-4):33-7. PubMed ID: 15726890
[TBL] [Abstract][Full Text] [Related]
11. [Formaldehyde exposure levels and exposure control measures during an anatomy dissecting course].
Tanaka K; Nishiyama K; Yaginuma H; Sasaki A; Maeda T; Kaneko SY; Onami T; Tanaka M
Kaibogaku Zasshi; 2003 Jun; 78(2):43-51. PubMed ID: 12833854
[TBL] [Abstract][Full Text] [Related]
12. Formaldehyde exposure of medical students and instructors and clinical symptoms during gross anatomy laboratory in Thammasat University.
Lakchayapakorn K; Watchalayarn P
J Med Assoc Thai; 2010 Dec; 93 Suppl 7():S92-8. PubMed ID: 21294402
[TBL] [Abstract][Full Text] [Related]
13. [Reducing the levels of formaldehyde exposure during a gross anatomy dissection course with a local ventilation system].
Kikuta A; Yamato H; Kunugita N; Nakashima T; Hayashi H
Kaibogaku Zasshi; 2010 Mar; 85(1):17-27. PubMed ID: 20384187
[TBL] [Abstract][Full Text] [Related]
14. [Vertical distribution of formaldehyde concentration and simulated temperature and wind velocity from computational fluid dynamics in a gross anatomy laboratory].
Takayanagi M; Fujita T; Mikuni T; Sakai M; Ishikawa Y; Murakami K; Kimura A; Kakuta S; Sato F
Kaibogaku Zasshi; 2008 Mar; 83(1):7-13. PubMed ID: 18416107
[TBL] [Abstract][Full Text] [Related]
15. The effects of enhanced formaldehyde clearance in a gross anatomy laboratory by floor plan redesign and dissection table adjustment.
Durongphan A; Rungruang J; Nitimanee E; Panichareon B
Environ Sci Pollut Res Int; 2023 May; 30(23):64246-64253. PubMed ID: 37062795
[TBL] [Abstract][Full Text] [Related]
16. A new system to reduce formaldehyde levels improves safety conditions during gross veterinary anatomy learning.
Nacher V; Llombart C; Carretero A; Navarro M; Ysern P; Calero S; FĂgols E; Ruberte J
J Vet Med Educ; 2007; 34(2):168-71. PubMed ID: 17446644
[TBL] [Abstract][Full Text] [Related]
17. Local ventilation system successfully reduced formaldehyde exposure during gross anatomy dissection classes.
Takahashi M; Abe M; Yamagishi T; Nakatani K; Okade T; Ogawa T; Konishi H; Kiryu-Seo S; Kiyama H; Nakajima Y
Anat Sci Int; 2010 Dec; 85(4):251-2. PubMed ID: 20734180
[No Abstract] [Full Text] [Related]
18. Reducing the levels of formaldehyde exposure in gross anatomy laboratories.
Coleman R
Anat Rec; 1995 Dec; 243(4):531-3. PubMed ID: 8597301
[TBL] [Abstract][Full Text] [Related]
19. A novel local ventilation system to reduce the levels of formaldehyde exposure during a gross anatomy dissection course and its evaluation using real-time monitoring.
Yamato H; Nakashima T; Kikuta A; Kunugita N; Arashidani K; Nagafuchi Y; Tanaka I
J Occup Health; 2005 Sep; 47(5):450-3. PubMed ID: 16230840
[No Abstract] [Full Text] [Related]
20. [Exposure to formaldehyde during an anatomy dissecting course].
Kunugita N; Nakashima T; Kikuta A; Kawamoto T; Arashidani K
J UOEH; 2004 Sep; 26(3):337-48. PubMed ID: 15471282
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]