BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

239 related articles for article (PubMed ID: 3329594)

  • 1. A critical review of EMG-controlled electrical stimulation in paraplegics.
    Graupe D; Kohn KH
    Crit Rev Biomed Eng; 1987; 15(3):187-210. PubMed ID: 3329594
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Above- and below-lesion EMG pattern mapping for controlling electrical stimulation of paraplegics to facilitate unbraced walker-assisted walking.
    Graupe D; Kohn KH; Basseas S
    J Biomed Eng; 1988 Jul; 10(4):305-11. PubMed ID: 3266276
    [TBL] [Abstract][Full Text] [Related]  

  • 3. EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking.
    Graupe D
    IEEE Trans Biomed Eng; 1989 Jul; 36(7):711-9. PubMed ID: 2787279
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Artificial neural network control of FES in paraplegics for patient responsive ambulation.
    Graupe D; Kordylewski H
    IEEE Trans Biomed Eng; 1995 Jul; 42(7):699-707. PubMed ID: 7622153
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electromyographic control of functional electrical stimulation in selected patients.
    Graupe D; Kohn KH; Basseas S; Naccarato E
    Orthopedics; 1984 Jul; 7(7):1134-8. PubMed ID: 24822823
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A gait stability investigation into FES-assisted paraplegic walking based on the walker tipping index.
    Ming D; Bai Y; Liu X; Qi H; Cheng L; Wan B; Hu Y; Wong Y; Luk KD; Leong JC
    J Neural Eng; 2009 Dec; 6(6):066007. PubMed ID: 19918110
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of a universal control unit for functional electrical stimulation (FES).
    Brandell BR
    Am J Phys Med; 1982 Dec; 61(6):279-301. PubMed ID: 6983299
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ambulation study of a woman with paraplegia using a reciprocating gait orthosis with functional electrical stimulation in Taiwan: a case report.
    Chen WL; Chang WH; Chen CC; Hsieh JC; Shih YY; Chen YL
    Disabil Rehabil Assist Technol; 2009 Nov; 4(6):429-38. PubMed ID: 19817657
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Energy cost and physiological reactions to effort during activation of paraplegics by functional electrical stimulation.
    Isakov E; Mizrahi J; Graupe D; Becker E; Najenson T
    Scand J Rehabil Med Suppl; 1985; 12():102-7. PubMed ID: 3879380
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Walking after partial paralysis assisted with EMG-triggered or switch-triggered functional electrical stimulation--two case studies.
    Dutta A; Kobetic R; Triolo R
    IEEE Int Conf Rehabil Robot; 2011; 2011():5975383. PubMed ID: 22275587
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gait initiation with electromyographically triggered electrical stimulation in people with partial paralysis.
    Dutta A; Kobetic R; Triolo RJ
    J Biomech Eng; 2009 Aug; 131(8):081002. PubMed ID: 19604014
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interfacing the body's own sensing receptors into neural prosthesis devices.
    Haugland M; Sinkjaer T
    Technol Health Care; 1999; 7(6):393-9. PubMed ID: 10665672
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A pilot study of myoelectrically controlled FES of upper extremity.
    Thorsen R; Spadone R; Ferrarin M
    IEEE Trans Neural Syst Rehabil Eng; 2001 Jun; 9(2):161-8. PubMed ID: 11474969
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patient-driven loop control for ambulation function restoration in a non-invasive functional electrical stimulation system.
    Chen WL; Chen SC; Chen CC; Chou CH; Shih YY; Chen YL; Kuo TS
    Disabil Rehabil; 2010; 32(1):65-71. PubMed ID: 19925278
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficacy and stability performance of traditional versus motion sensor-assisted strategies for FES standing.
    Braz GP; Russold M; Smith RM; Davis GM
    J Biomech; 2009 Jun; 42(9):1332-8. PubMed ID: 19349049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stimulation parameter optimization for FES supported standing up and walking in SCI patients.
    Bijak M; Rakos M; Hofer C; Mayr W; Strohhofer M; Raschka D; Kern H
    Artif Organs; 2005 Mar; 29(3):220-3. PubMed ID: 15725221
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Risk-tendency graph (RTG): a new gait-analysis technique for monitoring FES-assisted paraplegic walking stability.
    Ming D; Hu Y; Wong Y; Wan B; Luk KD; Leong JC
    Med Sci Monit; 2009 Aug; 15(8):MT105-12. PubMed ID: 19644428
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A decentralized modular control framework for robust control of FES-activated walker-assisted paraplegic walking using terminal sliding mode and fuzzy logic control.
    Nekoukar V; Erfanian A
    IEEE Trans Biomed Eng; 2012 Oct; 59(10):2818-27. PubMed ID: 22868526
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Activation of paraplegic patients by functional electrical stimulation: training and biomechanical evaluation.
    Braun Z; Mizrahi J; Najenson T; Graupe D
    Scand J Rehabil Med Suppl; 1985; 12():93-101. PubMed ID: 3879381
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Paraplegics standing up using multichannel FES and arm support.
    Kuzelicki J; Kamnik R; Bajd T; Obreza P; Benko H
    J Med Eng Technol; 2002; 26(3):106-10. PubMed ID: 12350276
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.