These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 3331162)
21. [Echocontrast ventriculography. Determination of left ventricular functional parameters with special reference to digital subtraction echocardiography]. Grube E; Lampen M; Becher H Z Kardiol; 1986 Nov; 75(11):650-8. PubMed ID: 3544548 [TBL] [Abstract][Full Text] [Related]
22. Determination of left ventricular ejection fraction by computer densitometric analysis of digital subtraction angiography: experimental validation and correlation with area-length methods. Nissen SE; Elion JL; Grayburn P; Booth DC; Wisenbaugh TW; DeMaria AN Am J Cardiol; 1987 Mar; 59(6):675-80. PubMed ID: 3548302 [TBL] [Abstract][Full Text] [Related]
24. Multiple-gated acquisition cardiac blood-pool isotope imaging. Evaluation of left ventricular function correlated with contrast angiography. Federman J; Brown ML; Tancredi RG; Smith HC; Wilson DB; Becker GP Mayo Clin Proc; 1978 Oct; 53(10):625-33. PubMed ID: 713592 [TBL] [Abstract][Full Text] [Related]
25. [Quantitative analysis of the left ventricular volume curve by digital subtraction angiography]. Ikeda H J Cardiol Suppl; 1987; 15():27-33. PubMed ID: 3334250 [TBL] [Abstract][Full Text] [Related]
26. Validation of the angiographic accuracy of digital left ventriculography. Nichols AB; Martin EC; Fles TP; Stugensky KM; Balancio LA; Casarella WJ; Weiss MB Am J Cardiol; 1983 Jan; 51(1):224-30. PubMed ID: 6849261 [TBL] [Abstract][Full Text] [Related]
27. Comparison of left ventricular ejection fraction by cine computed tomography and single plane right anterior oblique ventriculography. MacMillan RM; Rees MR; Maranhao V; Clark DL Angiology; 1986 Apr; 37(4):299-305. PubMed ID: 3717695 [TBL] [Abstract][Full Text] [Related]
28. Determination of cardiac ejection fraction and left ventricular volume: contrast-enhanced ultrafast cine MR imaging vs IV digital subtraction ventriculography. Matsumura K; Nakase E; Haiyama T; Takeo K; Shimizu K; Yamasaki K; Kohno K AJR Am J Roentgenol; 1993 May; 160(5):979-85. PubMed ID: 8470613 [TBL] [Abstract][Full Text] [Related]
29. Digital subtraction angiography of the left ventricle. Foster CJ; Butler P; Freer CE Br J Radiol; 1988 Nov; 61(731):1009-13. PubMed ID: 3061545 [TBL] [Abstract][Full Text] [Related]
30. Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction. Starling MR; Dell'Italia LJ; Walsh RA; Little WC; Benedetto AR; Nusynowitz ML J Am Coll Cardiol; 1984 Mar; 3(3):789-98. PubMed ID: 6693650 [TBL] [Abstract][Full Text] [Related]
31. Comparison of methods for determining absolute left ventricular volumes from radionuclide ventriculography. Warren SE; McKay RG; Aroesty JM; Heller GV; Kolodny GM; Royal HD Am J Physiol Imaging; 1987; 2(1):24-32. PubMed ID: 3451764 [TBL] [Abstract][Full Text] [Related]
32. Right ventricular function in healed myocardial infarction in man. A cineangiographic assessment. Boschat J; Etienne Y; Bellet M; Barra J; Blanc JJ; Penther P Eur J Radiol; 1985 Feb; 5(1):17-23. PubMed ID: 4006947 [TBL] [Abstract][Full Text] [Related]
33. Comparison of single and biplane ventriculography for determination of left ventricular volume and ejection fraction. Brogan WC; Glamann B; Lange RA; Hillis LD Am J Cardiol; 1992 Apr; 69(12):1079-82. PubMed ID: 1561982 [TBL] [Abstract][Full Text] [Related]
34. Improved densitometric measurement of left ventricular ejection fraction using dual-energy digital subtraction angiography. van Lysel MS; Miller WP; Fuerst TP; Albright DJ Int J Card Imaging; 1994 Jun; 10(2):113-21. PubMed ID: 7963749 [TBL] [Abstract][Full Text] [Related]
35. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. Williams KA; Taillon LA J Am Coll Cardiol; 1996 Jan; 27(1):173-81. PubMed ID: 8522692 [TBL] [Abstract][Full Text] [Related]
36. [Ventricular volumes determined by single-photon emission computed tomography]. Katohno E; Ono K; Owada K; Fujino A; Watanabe N; Sato M; Konno I; Yaoita H; Tsuda F; Kariyone S J Cardiol; 1987 Jun; 17(2):329-39. PubMed ID: 2834530 [TBL] [Abstract][Full Text] [Related]
37. Comparison of digital intravenous ventriculography with direct left ventriculography for quantitation of left ventricular volumes and ejection fractions. Norris SL; Slutsky RA; Mancini J; Ashburn WL; Gregoratos G; Peterson KL; Higgins CB Am J Cardiol; 1983 May; 51(8):1399-403. PubMed ID: 6846167 [TBL] [Abstract][Full Text] [Related]
38. Use of intravenous digital subtraction ventriculography in the evaluation of left ventricle volumes and ejection fraction. Perondi R; Gregorini L; Pomidossi G; Saino A; Alessio P; Zanchetti A; Mancia G Eur Heart J; 1991 Mar; 12(3):363-7. PubMed ID: 2040319 [TBL] [Abstract][Full Text] [Related]
39. Measurement of left ventricular ejection fraction by videodensitometric analysis of digital subtraction angiograms. Tobis J; Nalcioglu O; Seibert A; Johnston WD; Henry WL Am J Cardiol; 1983 Oct; 52(7):871-5. PubMed ID: 6353899 [TBL] [Abstract][Full Text] [Related]
40. Densitometric assessment of regional left ventricular systolic function during graded ischemia in the dog by use of dual-energy digital subtraction ventriculography. McCollough CH; Miller WP; Van Lysel MS; Folts JD; Peppler WW; Albright DJ Am Heart J; 1993 Jun; 125(6):1667-75. PubMed ID: 8498309 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]