These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

299 related articles for article (PubMed ID: 33312903)

  • 1. The incidence and impact of cardiac conduction disturbances after transcatheter aortic valve replacement.
    Chen S; Chau KH; Nazif TM
    Ann Cardiothorac Surg; 2020 Nov; 9(6):452-467. PubMed ID: 33312903
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictors for new-onset conduction block in patients with pure native aortic regurgitation after transcatheter aortic valve replacement with a new-generation self-expanding valve (VitaFlow Liberty
    Zhang X; Liang C; Zha L; Zuo Q; Hu G; Ding J; Tang S
    BMC Cardiovasc Disord; 2024 Jan; 24(1):77. PubMed ID: 38281925
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of baseline conduction abnormalities on outcomes after transcatheter aortic valve replacement with SAPIEN-3.
    Sammour Y; Sato K; Kumar A; Gajulapalli RD; Lak H; Chawla S; Banerjee K; Kaur M; Patel J; Incognito C; Svensson L; Popovic Z; Tarakji K; Wazni O; Reed GW; Yun J; Puri R; Krishnaswamy A; Kapadia SR
    Catheter Cardiovasc Interv; 2021 Jul; 98(1):E127-E138. PubMed ID: 33010100
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement.
    Sammour Y; Krishnaswamy A; Kumar A; Puri R; Tarakji KG; Bazarbashi N; Harb S; Griffin B; Svensson L; Wazni O; Kapadia SR
    JACC Cardiovasc Interv; 2021 Jan; 14(2):115-134. PubMed ID: 33478630
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New-onset left bundle branch block after transcatheter aortic valve replacement is associated with adverse long-term clinical outcomes in intermediate-risk patients: an analysis from the PARTNER II trial.
    Nazif TM; Chen S; George I; Dizon JM; Hahn RT; Crowley A; Alu MC; Babaliaros V; Thourani VH; Herrmann HC; Smalling RW; Brown DL; Mack MJ; Kapadia S; Makkar R; Webb JG; Leon MB; Kodali SK
    Eur Heart J; 2019 Jul; 40(27):2218-2227. PubMed ID: 31505615
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrophysiologic Implications of Transcatheter Aortic Valve Replacement: Incidence, Outcomes, and Current Management Strategies.
    Barrett C; Sandhu A; Tzou W
    Curr Cardiol Rep; 2021 Oct; 23(11):167. PubMed ID: 34599417
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A single-centre cohort and short-term follow-up of patients who developed persistent new onset left bundle branch block after transcatheter aortic valve replacement.
    Akdemir B; Roukoz H
    Acta Cardiol; 2020 Aug; 75(4):360-365. PubMed ID: 31984845
    [No Abstract]   [Full Text] [Related]  

  • 9. Conduction Disturbances After Transcatheter Aortic Valve Replacement: Current Status and Future Perspectives.
    Auffret V; Puri R; Urena M; Chamandi C; Rodriguez-Gabella T; Philippon F; Rodés-Cabau J
    Circulation; 2017 Sep; 136(11):1049-1069. PubMed ID: 28893961
    [TBL] [Abstract][Full Text] [Related]  

  • 10. How does new-onset left bundle branch block affect the outcomes of transcatheter aortic valve repair?
    Muntané-Carol G; Guimaraes L; Ferreira-Neto AN; Wintzer-Wehekind J; Junquera L; Del Val D; Faroux L; Philippon F; Rodés-Cabau J
    Expert Rev Med Devices; 2019 Jul; 16(7):589-602. PubMed ID: 31172837
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictors of Advanced Conduction Disturbances Requiring a Late (≥48 H) Permanent Pacemaker Following Transcatheter Aortic Valve Replacement.
    Mangieri A; Lanzillo G; Bertoldi L; Jabbour RJ; Regazzoli D; Ancona MB; Tanaka A; Mitomo S; Garducci S; Montalto C; Pagnesi M; Giannini F; Giglio M; Montorfano M; Chieffo A; Rodès-Cabau J; Monaco F; Paglino G; Della Bella P; Colombo A; Latib A
    JACC Cardiovasc Interv; 2018 Aug; 11(15):1519-1526. PubMed ID: 30093056
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Transcatheter aortic valve implantation and conduction disturbances].
    Ait Said M; Coquard C; Horvilleur J; Manenti V; Fiorina L; Lacotte J; Salerno F
    Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):443-449. PubMed ID: 31668339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation.
    Nijenhuis VJ; Van Dijk VF; Chaldoupi SM; Balt JC; Ten Berg JM
    Europace; 2017 Jun; 19(6):1015-1021. PubMed ID: 28340150
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conduction Disturbances and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: Predictors and Prevention.
    Tsoi M; Tandon K; Zimetbaum PJ; Frishman WH
    Cardiol Rev; 2022 Jul-Aug 01; 30(4):179-187. PubMed ID: 34132653
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-Term Ventricular Pacing Dependency and Pacemaker Implantation Predictors after Transcatheter Aortic Valve Replacement - A 1-Year Follow-Up.
    Pinto RA; Proença T; Carvalho MM; Pestana G; Lebreiro A; Adão L; Macedo F
    Arq Bras Cardiol; 2022 Oct; 119(4):522-530. PubMed ID: 35857943
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Frequency of conduction disturbances after Edwards SAPIEN percutaneous valve implantation.
    Laynez A; Ben-Dor I; Barbash IM; Hauville C; Sardi G; Maluenda G; Xue Z; Satler LF; Pichard AD; Lindsay J; Waksman R
    Am J Cardiol; 2012 Oct; 110(8):1164-8. PubMed ID: 22770935
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience.
    Nazif TM; Williams MR; Hahn RT; Kapadia S; Babaliaros V; Rodés-Cabau J; Szeto WY; Jilaihawi H; Fearon WF; Dvir D; Dewey TM; Makkar RR; Xu K; Dizon JM; Smith CR; Leon MB; Kodali SK
    Eur Heart J; 2014 Jun; 35(24):1599-607. PubMed ID: 24179072
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
    Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis.
    Faroux L; Chen S; Muntané-Carol G; Regueiro A; Philippon F; Sondergaard L; Jørgensen TH; Lopez-Aguilera J; Kodali S; Leon M; Nazif T; Rodés-Cabau J
    Eur Heart J; 2020 Aug; 41(29):2771-2781. PubMed ID: 31899484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.